Search icon

J & C STUCCO, INC.

Company Details

Name: J & C STUCCO, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 26 Apr 2006 (19 years ago)
Date of dissolution: 27 Apr 2011
Entity Number: 3353649
ZIP code: 11553
County: Nassau
Place of Formation: New York
Address: 852 BEDFORD COURT, UNIONDALE, NY, United States, 11553

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 852 BEDFORD COURT, UNIONDALE, NY, United States, 11553

Filings

Filing Number Date Filed Type Effective Date
DP-2002120 2011-04-27 DISSOLUTION BY PROCLAMATION 2011-04-27
060426000721 2006-04-26 CERTIFICATE OF INCORPORATION 2006-04-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
335708186 0215600 2012-08-13 177-41 EDGERTON ROAD, JAMAICA, NY, 11432
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2012-08-13
Emphasis L: FALL
Case Closed 2012-08-13

Related Activity

Type Inspection
Activity Nr 397882
Safety Yes
333978823 0215600 2012-04-18 177-41 EDGERTON ROAD, JAMAICA, NY, 11432
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2012-04-18
Emphasis L: FALL
Case Closed 2018-02-08

Related Activity

Type Inspection
Activity Nr 396763
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2012-06-05
Abatement Due Date 2012-06-08
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2012-07-03
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: A). On or about 04/18/12, at the site of 177-41 Edgerton Road. Jamaica Estates, NY An employee working on the lower level of the scaffold was in danger of head injury from falling objects such as, but not limited to tools and materials from other employee who on the third section of the scaffold. Protective helmets were not worn. ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2012-06-05
Abatement Due Date 2012-06-08
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2012-07-03
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked: A. On or about 04/18/12, scaffolds at 177-41 Edgerton Road. Jamaica Estates, NY Employees working on north side of the fabricated frame scaffolds were exposed to the hazard of falling approximately 18 ft to the ground. The working platforms were installed with only one or three scaffold planks. ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2012-06-05
Abatement Due Date 2012-06-08
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2012-07-03
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: A). On or about 04/18/12, at 177-41 Edgerton Road. Jamaica Estates, NY Employees were ascending/descending a scaffold by climbing the frame and were in danger of falling approximately 18 ft to the ground. An access ladder or equivalent safe devices were not provided. ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2012-06-05
Abatement Due Date 2012-06-08
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2012-07-03
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: A). On or about 04/18/12, scaffolds iat 177-41 Edgerton Road. Jamaica Estates, NY Employees applying stucco around the windows/house on the scaffold north side of the house were exposed to the hazard of falling approximately 18 ft. and 12 ft. to the ground, respectively. Guardrails or personal fall arrest systems were not provided. ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.

Date of last update: 28 Mar 2025