Search icon

S.G.S.V., INC.

Company Details

Name: S.G.S.V., INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 25 Aug 2006 (19 years ago)
Date of dissolution: 27 Apr 2011
Entity Number: 3404952
ZIP code: 11552
County: Nassau
Place of Formation: New York
Address: 768 MAPLE PLACE, WEST HEMPSTEAD, NY, United States, 11552

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 768 MAPLE PLACE, WEST HEMPSTEAD, NY, United States, 11552

Agent

Name Role Address
VINCENZO SICIGNANO Agent 768 MAPLE PLACE, WEST HEMPSTEAD, NY, 11552

Filings

Filing Number Date Filed Type Effective Date
DP-2010443 2011-04-27 DISSOLUTION BY PROCLAMATION 2011-04-27
081015000842 2008-10-15 CERTIFICATE OF CHANGE 2008-10-15
060825000077 2006-08-25 CERTIFICATE OF INCORPORATION 2006-08-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
338918170 0214700 2013-02-25 157 ALBANY AVENUE, AMITYVILLE, NY, 11701
Inspection Type FollowUp
Scope NoInspection
Safety/Health Safety
Close Conference 2013-02-25
Emphasis L: FALL
Case Closed 2013-03-04

Related Activity

Type Inspection
Activity Nr 477158
Safety Yes
334771581 0214700 2012-06-15 157 ALBANY AVE, AMITYVILLE, NY, 11701
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-06-21
Emphasis L: FALL, N: CTARGET
Case Closed 2017-10-30

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2012-09-17
Abatement Due Date 2012-09-18
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2012-10-11
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 1926.100(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets. Worksite, West - Employees were observed working under other workers in areas where objects such as, but not limited to, hand tools, containers of stucco and other finishing supplies could potentially fall on, or about, 06/15/12. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2012-09-17
Abatement Due Date 2012-09-18
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2012-10-11
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) Worksite, east - Employees were working on a scaffold at the heights of approximately 12 feet. The scaffold was not fully planked on, or about, 06/15/12. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2012-09-17
Abatement Due Date 2012-09-18
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2012-10-11
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Worksite, east - Employees engaged in stucco work on a commercial building were observed working on a scaffold approximately 12 feet above the ground. Personnel were accessing the top platform by climbing the scaffold. There was no safe access on, or about, 06/15/12. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2012-09-17
Abatement Due Date 2012-09-24
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2012-10-11
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 1926.451(g)(1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level. Worksite, east - Employees were working on a scaffold at the heights of approximately 12 feet without being protected from falls by personal falls arrest systems or guardrails on, or about, 06/15/12. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.