Name: | GAUTHIER SHEET METAL, INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 09 Apr 1974 (51 years ago) |
Entity Number: | 340784 |
ZIP code: | 13501 |
County: | Oneida |
Place of Formation: | New York |
Address: | 1201 BROAD ST, UTICA, NY, United States, 13501 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
CHRISTOPHER R. GAUTHIER, PRESIDENT | Chief Executive Officer | 1201 BROAD ST, UTICA, NY, United States, 13501 |
Name | Role | Address |
---|---|---|
GAUTHIER SHEET METAL, INC. | DOS Process Agent | 1201 BROAD ST, UTICA, NY, United States, 13501 |
Start date | End date | Type | Value |
---|---|---|---|
1974-04-09 | 1992-12-09 | Address | 1201 BROAD ST, UTICA, NY, 13501, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
220504003917 | 2022-05-04 | BIENNIAL STATEMENT | 2022-04-01 |
140418006019 | 2014-04-18 | BIENNIAL STATEMENT | 2014-04-01 |
120529002348 | 2012-05-29 | BIENNIAL STATEMENT | 2012-04-01 |
100429002758 | 2010-04-29 | BIENNIAL STATEMENT | 2010-04-01 |
080404002822 | 2008-04-04 | BIENNIAL STATEMENT | 2008-04-01 |
060419003146 | 2006-04-19 | BIENNIAL STATEMENT | 2006-04-01 |
C347890-2 | 2004-05-24 | ASSUMED NAME LLC INITIAL FILING | 2004-05-24 |
040514002076 | 2004-05-14 | BIENNIAL STATEMENT | 2004-04-01 |
020327002400 | 2002-03-27 | BIENNIAL STATEMENT | 2002-04-01 |
000413002102 | 2000-04-13 | BIENNIAL STATEMENT | 2000-04-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345211403 | 0215800 | 2021-03-22 | 1201 BROAD ST., UTICA, NY, 13501 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1714391 |
Safety | Yes |
Health | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Other |
Standard Cited | 19100178 L01 I |
Issuance Date | 2021-09-17 |
Current Penalty | 0.0 |
Initial Penalty | 2340.0 |
Final Order | 2021-09-27 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) At the establishment, on or about 3/22/21: Employees operating powered industrial trucks including but not limited to: Yale and Hyster were not provided with training. |
Citation ID | 01001B |
Citaton Type | Other |
Standard Cited | 19100178 L04 III |
Issuance Date | 2021-09-17 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-09-27 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) At the establishment, on or about 3/22/2021: The employer had not provided an evaluation of each powered industrial truck operator at least once every three years. Last training was conducted June 2017. Employees operating powered industrial trucks including but not limited to: Yale and Hyster. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19101200 E01 |
Issuance Date | 2021-09-17 |
Current Penalty | 2340.0 |
Initial Penalty | 2340.0 |
Final Order | 2021-09-27 |
Nr Instances | 1 |
Nr Exposed | 4 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met; specifically: 1) Labeling and other forms of warning; 2) SDS requirements for the hazardous materials known to be present at the jobsite; 3) Employee training and information. The written program must also include: (a) A list of all the chemicals used at the jobsite. (b) Methods to inform employees of hazards associated with non-routine tasks. (c) Methods the employer will use to inform any contractors employees of workplace hazards. a) At the establishment, on or about 3/22/2021: A written hazard communication program was not developed for the employees who work with hazardous materials including but not limited to: Acetylene; Argon; Helium; Hydrogen; Oxygen; Propane; Stainless Steel; Carbon Steel and Aluminum. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19101200 H01 |
Issuance Date | 2021-09-17 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-09-27 |
Nr Instances | 1 |
Nr Exposed | 4 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) At the establishment, on or about 3/22/2021: Employees were exposed to hazardous chemicals such as, but not limited to: Acetylene; Argon; Helium; Hydrogen; Oxygen; Propane; Stainless Steel; Carbon Steel and Aluminum and were not provided information and training as specified in 29 CFR 1910.1200(h)(1) and (2). |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19101026 D01 |
Issuance Date | 2021-09-17 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-09-27 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1026(d)(1):The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): a) At the establishment, on or about 3/22/21: The exposure to Chromium (VI) was not determined for employees Tig Welding on Stainless Steel Alloy. |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2021-08-24 |
Emphasis | N: AMPUTATE, P: AMPUTATE |
Case Closed | 2022-01-24 |
Related Activity
Type | Complaint |
Activity Nr | 1714391 |
Safety | Yes |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100212 A03 II |
Issuance Date | 2021-09-17 |
Current Penalty | 2633.0 |
Initial Penalty | 3901.0 |
Final Order | 2021-09-27 |
Nr Instances | 1 |
Nr Exposed | 5 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) The Shop Floor, on or about 3/22/2021: Point of operation on a Cincinnati Shear was not adequately guarded in that there were openings in the 11 hold down guards that measured from 1-inch to 5 1/2 - inches. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19100215 A04 |
Issuance Date | 2021-09-17 |
Current Penalty | 1579.0 |
Initial Penalty | 2340.0 |
Final Order | 2021-09-27 |
Nr Instances | 1 |
Nr Exposed | 5 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) The Shop Floor, on or about 3/22/21: A Divine Pedestal Grinder had an opening between the work rest and grinding wheel that measured 5 1/2-inch at the left wheel and 8-inch at the right wheel. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19100215 B09 |
Issuance Date | 2021-09-17 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-09-27 |
Nr Instances | 1 |
Nr Exposed | 5 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) The Shop Floor, on or about 3/22/21: A Divine Pedestal Grinder had an opening between the tongue guard and grinding wheel that measured 2-inches at the left wheel and 1 3/4-inches at the right wheel. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 1987-12-21 |
Case Closed | 1988-02-29 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260020 B01 |
Issuance Date | 1988-01-12 |
Abatement Due Date | 1988-02-17 |
Current Penalty | 80.0 |
Initial Penalty | 80.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260021 B02 |
Issuance Date | 1988-01-12 |
Abatement Due Date | 1988-02-17 |
Nr Instances | 1 |
Nr Exposed | 3 |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19260404 A02 |
Issuance Date | 1988-01-12 |
Abatement Due Date | 1988-01-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Citation ID | 02003 |
Citaton Type | Other |
Standard Cited | 19260404 F07 IVC |
Issuance Date | 1988-01-12 |
Abatement Due Date | 1988-01-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3716198305 | 2021-01-22 | 0248 | PPS | 1201 Broad St, Utica, NY, 13501-1603 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
8752497109 | 2020-04-15 | 0248 | PPP | 1201 Broad Street, Utica, NY, 13501 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1365646 | Intrastate Non-Hazmat | 2021-04-07 | 591000 | 2021 | 3 | 2 | Private(Property) | |||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 0 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | 0 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 0 |
Vehicle Maintenance BASIC Roadside Performance measure value | 0 |
Total Number of Vehicle Inspections for the measurement period | 0 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 0 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 0 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 0 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |
Date of last update: 18 Mar 2025
Sources: New York Secretary of State