Search icon

PARK PALLET INC.

Company Details

Name: PARK PALLET INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 01 Dec 2006 (18 years ago)
Entity Number: 3444241
ZIP code: 11207
County: Kings
Place of Formation: New York
Address: 1862 LINDEN BOULEVARD, BROOKLYN, NY, United States, 11207

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 1862 LINDEN BOULEVARD, BROOKLYN, NY, United States, 11207

History

Start date End date Type Value
2006-12-01 2023-01-26 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
061201000557 2006-12-01 CERTIFICATE OF INCORPORATION 2006-12-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341729085 0215000 2016-08-24 554 MONTAUK AVENUE, BROOKLYN, NY, 11208
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2016-08-24
Emphasis L: FORKLIFT, N: AMPUTATE
Case Closed 2022-07-29

Related Activity

Type Complaint
Activity Nr 1128014
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100110 F02 II
Issuance Date 2017-02-21
Current Penalty 3347.0
Initial Penalty 3622.0
Final Order 2017-03-21
Nr Instances 1
Nr Exposed 12
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.110(f)(2)(ii): Containers when stored inside shall not be located near exits, stairways, or in areas normally used or intended for the safe exit of people. Location: 554 Montauk Ave, Brooklyn, NY. On or about: August 24, 2016 a) 23 propane containers were stored outside the doorway of the employees locker room, and under the only access staircase leading to the upper floor office.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100110 F06 II
Issuance Date 2017-02-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-03-21
Nr Instances 1
Nr Exposed 12
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.110(f)(6)(ii): Containers were not stored in a suitable enclosure or otherwise protected against tampering. Location: 554 Montauk Ave, Brooklyn, NY. On or about: August 24, 2016 a) 11 propane containers were store outside the designated propane storage enclosure. The enclosure has a capacity of storing 12 such containers and it was fully occupied at the time of inspection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100176 B
Issuance Date 2017-02-21
Current Penalty 1273.0
Initial Penalty 2173.0
Final Order 2017-03-21
Nr Instances 1
Nr Exposed 12
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse. Location: In the middle of the yard at 554 Montauk Ave, Brooklyn, NY. On or about: August 24, 2016 a) Stock materials were stored in multiple tiers, reaching over 14 feet high and leaning. They were not secured to prevent from collapse.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100178 P01
Issuance Date 2017-02-21
Current Penalty 1273.0
Initial Penalty 2173.0
Final Order 2017-03-21
Nr Instances 1
Nr Exposed 12
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(p)(1): Where powered industrial trucks were found to be in need of repair, defective, or in any way unsafe, the trucks were not taken out of service until they had been restored to safe operating condition. Location: 554 Montauk Ave, Brooklyn, NY. On or about: August 24, 2016 a) A Yale forklift in need of repair was in being used to move material in the yard. The left rear wheel had extensive wear and damage.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100303 B07 I
Issuance Date 2017-02-21
Abatement Due Date 2017-03-03
Current Penalty 1273.0
Initial Penalty 2173.0
Final Order 2017-03-21
Nr Instances 2
Nr Exposed 12
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. Location: 554 Montauk Avenue, Brooklyn, NY 11208 On or about: 8/24/2016 a) The cover of a pull box at the interlock switch for the circular table saw was missing. The electrical wires inside were not effectively protected by the housing of the pull box. b) An unused knock-out opening at the housing of the switch to the area light in front of the employee locker room was not covered. The electrical wires inside were not effectively protected by the housing of the switch.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100303 G02 I
Issuance Date 2017-02-21
Current Penalty 1917.0
Initial Penalty 2897.0
Final Order 2017-03-21
Nr Instances 1
Nr Exposed 12
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i). Location: On the South Wall of the yard at 554 Montauk Ave, Brooklyn, NY. On or about: August 24, 2016 a) An energized electrical panel breaker box was missing the cover.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 2017-02-21
Abatement Due Date 2017-03-03
Current Penalty 1917.0
Initial Penalty 2897.0
Final Order 2017-03-21
Nr Instances 2
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords or cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws. Location: 554 Montauk Ave, Brooklyn, NY 11208 On or about: August 24, 2016 a) The power cable cord connected to the ON/OFF switch of the horizontal band saw was pulled out of the fitting, and not provided with strain relief. the wires exposing the wires. b) The power cable cord connecting an interlock switch of a the circular table saw was pulled out of the fitting, and not provided with strain relief. The wires were exposed.