Search icon

ST. LAWRENCE BUILDERS, INC.

Company Details

Name: ST. LAWRENCE BUILDERS, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 21 Dec 2006 (18 years ago)
Date of dissolution: 27 Jul 2011
Entity Number: 3452220
ZIP code: 13662
County: St. Lawrence
Place of Formation: New York
Principal Address: 116 COUNTY RTE 41, MASSENA, NY, United States, 13662
Address: 116 COUNTY ROUTE 41, MASSENA, NY, United States, 13662

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 116 COUNTY ROUTE 41, MASSENA, NY, United States, 13662

Chief Executive Officer

Name Role Address
LARRY LEGAULT Chief Executive Officer 116 COUNTY RTE 41, MASSENA, NY, United States, 13662

History

Start date End date Type Value
2006-12-21 2022-07-05 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
DP-2020847 2011-07-27 DISSOLUTION BY PROCLAMATION 2011-07-27
081223003294 2008-12-23 BIENNIAL STATEMENT 2008-12-01
061221000294 2006-12-21 CERTIFICATE OF INCORPORATION 2006-12-21

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339395840 0215800 2013-09-05 13 ST LAWRENCE CRESCENTS, WADDINGTON, NY, 13694
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2013-09-05
Emphasis L: FALL, P: FALL
Case Closed 2016-07-13

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-10-23
Abatement Due Date 2013-11-04
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2013-12-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 13 St. Lawrence Crescents, Waddington NY - On or about 5 September, 2013 - Employees were working on a residential roof above 6 feet without the use of personal fall protection.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-10-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-12-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 13 St. Lawrence Crescents, Waddington NY - On or about 5 September, 2013 - Employees were using a portable ladder to access the upper landing surface that did not have the side rails extended a minimum of 3 feet above the upper landing surface.
Citation ID 02001A
Citaton Type Other
Standard Cited 19260404 B01 I
Issuance Date 2013-10-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-12-27
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) 13 St. Lawrence Crescents, Waddington NY - On or about 5 September, 2013 - Employees were using a portable saw connected to an extension cord that was not protected through the use of a ground fault circuit interrupter.
Citation ID 02001B
Citaton Type Other
Standard Cited 19260403 B02
Issuance Date 2013-10-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-12-27
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) 13 St. Lawrence Crescents, Waddington, NY - On or about 6 September, 2013 - Employees were using a 4 gang outlet box that was being used or installed in accordance with manufacturers instructions or listing.