Search icon

FRANCHISE CONTRACTORS, LLC

Headquarter

Company Details

Name: FRANCHISE CONTRACTORS, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 12 Jan 2007 (18 years ago)
Entity Number: 3461634
ZIP code: 10523
County: Westchester
Place of Formation: New York
Address: 45 KNOLLWOOD RD, STE 101, ELMSFORD, NY, United States, 10523

Links between entities

Type Company Name Company Number State
Headquarter of FRANCHISE CONTRACTORS, LLC, CONNECTICUT 0987342 CONNECTICUT

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent 45 KNOLLWOOD RD, STE 101, ELMSFORD, NY, United States, 10523

History

Start date End date Type Value
2007-05-21 2011-02-17 Address 600 MAMARONECK AVE SUITE 400, HARRISON, NY, 10528, USA (Type of address: Service of Process)
2007-01-12 2007-05-21 Address ATTN: FRANCESCO LOMBARDI, P.O. BOX 1051, PELHAM, NY, 10803, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
130308006219 2013-03-08 BIENNIAL STATEMENT 2013-01-01
110217002282 2011-02-17 BIENNIAL STATEMENT 2011-01-01
090128002170 2009-01-28 BIENNIAL STATEMENT 2009-01-01
070521000758 2007-05-21 CERTIFICATE OF AMENDMENT 2007-05-21
070517000102 2007-05-17 CERTIFICATE OF PUBLICATION 2007-05-17
070112000413 2007-01-12 ARTICLES OF ORGANIZATION 2007-01-12

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2018-12-06 No data EXCHANGE ALLEY, FROM STREET BROADWAY TO STREET TRINITY PLACE No data Street Construction Inspections: Post-Audit Department of Transportation curb acceptable.
2018-10-31 No data EXCHANGE ALLEY, FROM STREET BROADWAY TO STREET TRINITY PLACE No data Street Construction Inspections: Post-Audit Department of Transportation curb acceptable
2017-02-20 No data EXCHANGE ALLEY, FROM STREET BROADWAY TO STREET TRINITY PLACE No data Street Construction Inspections: Post-Audit Department of Transportation Curb repairs - distinctive 2'x2" rectangular paver sidewalk acceptable. Metal face curb not touch.
2016-07-14 No data EXCHANGE ALLEY, FROM STREET BROADWAY TO STREET TRINITY PLACE No data Street Construction Inspections: Post-Audit Department of Transportation curb acceptable
2016-05-17 No data EXCHANGE ALLEY, FROM STREET BROADWAY TO STREET TRINITY PLACE No data Street Construction Inspections: Post-Audit Department of Transportation curb reset acceptable
2016-05-03 No data TRINITY PLACE, FROM STREET EXCHANGE ALLEY TO STREET RECTOR STREET No data Street Construction Inspections: Active Department of Transportation no occupancy of s/w
2016-04-26 No data EXCHANGE ALLEY, FROM STREET BROADWAY TO STREET TRINITY PLACE No data Street Construction Inspections: Post-Audit Department of Transportation curb reset acceptable
2016-03-11 No data TRINITY PLACE, FROM STREET EDGAR STREET TO STREET EXCHANGE ALLEY No data Street Construction Inspections: Pick-Up Department of Transportation Respondent storing Bobcat on roadway along parking lane without valid permit on file.
2016-02-24 No data BROADWAY, FROM STREET EXCHANGE ALLEY TO STREET MORRIS STREET No data Street Construction Inspections: Active Department of Transportation Upon inspection, plastic barriers with metal chain on top acceptable.
2016-02-24 No data EXCHANGE ALLEY, FROM STREET BROADWAY TO STREET TRINITY PLACE No data Street Construction Inspections: Active Department of Transportation Upon inspection, plastic barriers with metal chain on top on alley acceptable.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
333907244 0216000 2012-04-18 332 BEDFORD RD., BEDFORD HILLS, NY, 10507
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-05-03
Emphasis L: FALL
Case Closed 2013-05-28

Related Activity

Type Inspection
Activity Nr 413742
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2012-10-17
Current Penalty 660.0
Initial Penalty 1320.0
Contest Date 2012-11-02
Final Order 2013-03-13
Nr Instances 2
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: location: stair tower on or about: 4/18/12 a) Employees, installing the drop ceiling and doing electrical work, were working from a tubular welded frame scaffold. The scaffold did not bear on base plates. location: front of the building on or about: 4/18/12 b) Employees, caulking and installing the window drop edge, were working from a tubular welded frame scaffold. 2 of the 4 scaffold poles did not bear on base plates.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2012-10-17
Current Penalty 1100.0
Initial Penalty 2200.0
Contest Date 2012-11-02
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: location: stair tower on or about: 4/18/12 a) Employees, installing the drop ceiling and doing electrical work, were working from a tubular welded frame scaffold without fall protection. The employees were exposed to a fall of 12 feet 11 inches.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2012-10-17
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2012-11-02
Final Order 2013-03-13
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: location: stair tower on or about: 4/18/12 a) Employees were installing the drop ceiling from tubular welded frame scaffolding. The employees were not provided with scaffold safety training.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2012-10-17
Current Penalty 1100.0
Initial Penalty 2200.0
Contest Date 2012-11-02
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: location: roof on or about: 4/18/12 a) Employees, who were installing trim from the roof, were not provided with any means of fall protection. The employees were exposed to a fall of 32 feet.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2012-10-17
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2012-11-02
Final Order 2013-03-13
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: location: roof on or about: 4/18/12 a) Employees, who were installing trim from the roof and exposed to falls of 32 feet, were not provided with fall protection training.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260502 I03
Issuance Date 2012-10-17
Current Penalty 660.0
Initial Penalty 1320.0
Contest Date 2012-11-02
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees. location: stair tower on or about: 4/18/12 a) Employees were working beside 2 pieces of plywood that were covering the flag pole opening. The plywood cover of the 2'10" diameter opening was not secured.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260502 I04
Issuance Date 2012-10-17
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2012-11-02
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(4): All covers were not color coded or they shall be marked with the word "HOLE" or "COVER" to provide warning of the hazard: Note: This provision does not apply to cast iron manhole covers or steel grates used on streets or roadways. location: stair tower on or about: 4/18/12 a) Employees were working beside 2 pieces of plywood that were covering the flag pole opening. The plywood cover of the 2'10" diameter opening was not color coded or marked.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2012-10-17
Current Penalty 660.0
Initial Penalty 1320.0
Contest Date 2012-11-02
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support: location: rear of building on or about: 4/18/12 a) Employees were using a Louisville extension ladder to access the roof. The ladder only extended 1 foot above the roof.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260404 B01 I
Issuance Date 2012-10-17
Current Penalty 1760.0
Initial Penalty 3520.0
Contest Date 2012-11-02
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): General. The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors: location: rear of building on or about: 4/18/12 a) Employees were using electrical equipment, including but not limited to a Makita 9557NB grinder, while engaged in tile work. The employees were not provided with GFCI protection or an assured equipment grounding conductor program. FRANCHISE CONTRACTORS, LLC WAS PREVIOUSLY CITED SERIOUS FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.404(b)(1)(i) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314979618 CITATION NUMBER 1 ITEM 2 AND WAS AFFIRMED AS FINAL ORDER ON 1/30/2012, WITH RESPECT TO A WORKPLACE LOCATED AT 332 BEDFORD CENTER RD., BEDFORD HILLS, NY.
Citation ID 02002
Citaton Type Repeat
Standard Cited 19260453 B02 V
Issuance Date 2012-10-17
Current Penalty 2200.0
Initial Penalty 4400.0
Contest Date 2012-11-02
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt was not worn and a lanyard attached to the boom or basket when working from an aerial lift. Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e): location: front of building on or about: 4/18/12 a) An employee was installing trim to the top of the firehouse. The employee, working from a Genie S-45 areial lift, was not using a body belt or personal fall arrest system. FRANCHISE CONTRACTORS, LLC WAS PREVIOUSLY CITED SERIOUS FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.453(b)(2)(v) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 315752121 CITATION NUMBER 1 ITEM 4 AND WAS AFFIRMED AS FINAL ORDER ON 1/30/2012, WITH RESPECT TO A WORKPLACE LOCATED AT 138 STATE ROUTE 94, WARWICK, NY.
315752121 0213100 2012-01-17 138 STATE ROUTE 94, WARWICK, NY, 10990
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2012-01-17
Emphasis S: FALL FROM HEIGHT, S: ELECTRICAL
Case Closed 2012-10-24

Related Activity

Type Referral
Activity Nr 202973517
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2012-01-25
Abatement Due Date 2012-02-02
Current Penalty 612.0
Initial Penalty 2040.0
Contest Date 2012-02-06
Final Order 2012-06-15
Nr Instances 1
Nr Exposed 2
Gravity 05
Citation ID 01002
Citaton Type Serious
Standard Cited 19260153 J
Issuance Date 2012-01-25
Abatement Due Date 2012-02-02
Current Penalty 612.0
Initial Penalty 2040.0
Contest Date 2012-02-06
Final Order 2012-06-15
Nr Instances 1
Nr Exposed 6
Gravity 05
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260403 I02 II
Issuance Date 2012-01-25
Abatement Due Date 2012-02-02
Current Penalty 765.0
Initial Penalty 2550.0
Contest Date 2012-02-06
Final Order 2012-06-15
Nr Instances 1
Nr Exposed 6
Gravity 05
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260405 A02 IIB
Issuance Date 2012-01-25
Abatement Due Date 2012-02-02
Contest Date 2012-02-06
Final Order 2012-06-15
Nr Instances 1
Nr Exposed 6
Gravity 05
Citation ID 01004
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2012-01-25
Abatement Due Date 2012-01-30
Current Penalty 765.0
Initial Penalty 2550.0
Contest Date 2012-02-06
Final Order 2012-06-15
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 05
314980095 0216000 2011-09-12 332 BEDFORD CENTER RD., BEDFORD HILLS, NY, 10507
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2011-09-14
Case Closed 2011-09-27
314979618 0216000 2011-08-04 332 BEDFORD CENTER RD., BEDFORD HILLS, NY, 10507
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2011-08-08
Emphasis L: LOCALTARG, L: FALL, S: FALL FROM HEIGHT
Case Closed 2014-08-26

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260200 G02
Issuance Date 2011-09-15
Abatement Due Date 2011-09-20
Current Penalty 1530.0
Initial Penalty 2550.0
Contest Date 2011-10-04
Final Order 2012-02-16
Nr Instances 1
Nr Exposed 2
Gravity 05
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2011-09-15
Abatement Due Date 2011-09-20
Current Penalty 1530.0
Initial Penalty 2550.0
Contest Date 2011-10-04
Final Order 2012-02-16
Nr Instances 1
Nr Exposed 4
Gravity 05
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B14
Issuance Date 2011-09-15
Abatement Due Date 2011-09-20
Current Penalty 1530.0
Initial Penalty 2550.0
Contest Date 2011-10-04
Final Order 2012-02-16
Nr Instances 1
Nr Exposed 2
Gravity 05

Date of last update: 28 Mar 2025