Filings

Filing Number Date Filed Type Effective Date
071213000544 2007-12-13 CERTIFICATE OF DISSOLUTION 2007-12-13
070202001094 2007-02-02 CERTIFICATE OF INCORPORATION 2007-02-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339504896 0214700 2013-12-03 1989 MERRICK RD., MERRICK, NY, 11566
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-12-03
Emphasis L: FALL, L: SANDY, P: FALL
Case Closed 2014-12-16

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2014-01-21
Abatement Due Date 2014-01-27
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-02-18
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided: a) Worksite - Employees were grinding without eye protection; on or about 12/3/13. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2014-01-21
Abatement Due Date 2014-01-27
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-02-18
Nr Instances 3
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) Worksite - a) worksite - Employees were grinding steel from a fabricated frame scaffold approximately 20 feet above the ground. The scaffold platforms were not fully planked; on or about 12/03/2013. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2014-01-21
Abatement Due Date 2014-01-27
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-02-18
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) worksite - Employees grinding steel from a fabricated frame scaffold approximately 20 feet above the ground were not protected from falling; on or about 12/03/2013. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.