Name: | ELMWOOD VILLAGE CONTRACTING SERVICES, LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 06 Feb 2007 (18 years ago) |
Entity Number: | 3473310 |
ZIP code: | 14209 |
County: | Erie |
Place of Formation: | New York |
Address: | 1131 DELAWARE AVE, BUFFALO, NY, United States, 14209 |
Name | Role | Address |
---|---|---|
ELMWOOD VILLAGE CONTRACTING SERVICES, LLC | DOS Process Agent | 1131 DELAWARE AVE, BUFFALO, NY, United States, 14209 |
Start date | End date | Type | Value |
---|---|---|---|
2014-09-22 | 2015-12-21 | Name | SOJASTAN HOLDINGS, LLC |
2013-03-06 | 2025-02-13 | Address | 1131 DELAWARE AVE, BUFFALO, NY, 14209, USA (Type of address: Service of Process) |
2007-02-06 | 2014-09-22 | Name | ELMWOOD VILLAGE CONTRACTING SERVICES, LLC |
2007-02-06 | 2013-03-06 | Address | 436 GRANT STREET, BUFFALO, NY, 14213, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
250213003019 | 2025-02-13 | BIENNIAL STATEMENT | 2025-02-13 |
230203002178 | 2023-02-03 | BIENNIAL STATEMENT | 2023-02-01 |
220505004046 | 2022-05-05 | BIENNIAL STATEMENT | 2021-02-01 |
190212060513 | 2019-02-12 | BIENNIAL STATEMENT | 2019-02-01 |
170202007350 | 2017-02-02 | BIENNIAL STATEMENT | 2017-02-01 |
160301006355 | 2016-03-01 | BIENNIAL STATEMENT | 2015-02-01 |
151221000095 | 2015-12-21 | CERTIFICATE OF AMENDMENT | 2015-12-21 |
140922000668 | 2014-09-22 | CERTIFICATE OF AMENDMENT | 2014-09-22 |
130306002309 | 2013-03-06 | BIENNIAL STATEMENT | 2013-02-01 |
110225002716 | 2011-02-25 | BIENNIAL STATEMENT | 2011-02-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341347284 | 0213600 | 2016-03-21 | 918 MAIN STREET, BUFFALO, NY, 14202 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260300 B01 |
Issuance Date | 2016-07-06 |
Current Penalty | 1100.0 |
Initial Penalty | 1600.0 |
Contest Date | 2016-07-27 |
Final Order | 2017-01-03 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) On or about 3/21/16 at a renovation project located at 918 Main Street, Buffalo, New York; an employee repairing masonry on the front of building was using a 7" Makita angle grinder to clean and repair masonry block. There was no guard on the grinder. b) On or about 3/21/16 at a renovation project located at 918 Main Street, Buffalo, New York; an employee repairing masonry on the front of building was using a 4" Bosch angle grinder to clean and repair masonry block. There was no guard on the grinder. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002 |
Citaton Type | Other |
Standard Cited | 19260416 E01 |
Issuance Date | 2016-07-06 |
Current Penalty | 0.0 |
Initial Penalty | 1200.0 |
Contest Date | 2016-07-27 |
Final Order | 2017-01-03 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) On or about 3/21/16 at a renovation project located at 918 Main Street, Buffalo, New York; an employee grinding masonry on the front of building was using an extension cord that had a damaged jacket. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2016-07-06 |
Current Penalty | 1100.0 |
Initial Penalty | 1600.0 |
Contest Date | 2016-07-27 |
Final Order | 2017-01-03 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A safety harness with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a) On or about 3/21/16 at a renovation project located at 918 Main Street, Buffalo, New York; an employee grinding masonry on the front of building was using a boom lift to access work areas. The employee in the lift did not have a harness with lanyard attached to the boom or basket. NO ABATEMENT CERTIFICATION REQUIRED |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2013-03-25 |
Emphasis | P: FALL, L: FALL |
Case Closed | 2013-05-03 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260021 B02 |
Issuance Date | 2013-04-08 |
Abatement Due Date | 2013-04-24 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-04-30 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about 3/25/13 at residential roofing construction site 196 Linwood Ave., Buffalo, NY: Employees engaged in roofing work were exposed to a potential fall of approx. 22 ft. from the south side of the roof. Employees were not trained to recognize potential hazards on this type of jobsite including falls from roofs, ladders, scaffolds, & electrical hazards as well as the regulations applicable to controlling or eliminating these hazards. ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2013-04-08 |
Current Penalty | 800.0 |
Initial Penalty | 1700.0 |
Final Order | 2013-04-12 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) On or about 3/25/13 at residential roofing construction site 196 Linwood Ave., Buffalo, NY: Employees engaged in roofing work were exposed to a potential fall of approx. 22 ft. from the south side of the roof. No guardrail system, safety net system, or personal fall arrest system was utilized. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01003 |
Citaton Type | Other |
Standard Cited | 19261053 B01 |
Issuance Date | 2013-04-08 |
Current Penalty | 0.0 |
Initial Penalty | 1700.0 |
Final Order | 2013-04-12 |
Nr Instances | 1 |
Nr Exposed | 4 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders' length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 3/25/13 at residential roofing construction site 196 Linwood Ave., Buffalo, NY: Employees were exposed to a fall of approx. 22 ft. when an extension ladder was used to access the roof from the ground. The siderails of the ladder only extended approx. 13 inches above the roof. NO ABATEMENT CERTIFICATION REQUIRED |
Date of last update: 28 Mar 2025
Sources: New York Secretary of State