339492977
|
0213400
|
2013-11-20
|
3231 RICHMOND AVENUE, STATEN ISLAND, NY, 10312
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-11-20
|
Emphasis |
L: FALL, N: SVEP
|
Case Closed |
2018-05-03
|
Related Activity
Type |
Complaint |
Activity Nr |
862837 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260451 E01 |
Issuance Date |
2014-01-24 |
Current Penalty |
6000.0 |
Initial Penalty |
15400.0 |
Contest Date |
2014-05-01 |
Final Order |
2014-10-31 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): Scaffold platforms were more than 2 feet above or below point of access, was not provided with a ladder and or direct access from another structure. Cross braces were used as a means of access to platforms: a) On or about 11/20/13 CSHOs observed four employees climb and use the cross braces of 2 tubular welded rolling scaffolds to access the walking/working platforms when ladders had not been provided. L & J Stucco was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(e)(1), which was contained in OSHA inspection number 491718, citation number 1, item number 3 and was affirmed as a final order on 01/14/2013, with respect to a workplace located at 197 West Old Country Road, Hicksville, NY 11801. |
|
Citation ID |
01002 |
Citaton Type |
Repeat |
Standard Cited |
19260451 G01 |
Issuance Date |
2014-01-24 |
Current Penalty |
6000.0 |
Initial Penalty |
15400.0 |
Contest Date |
2014-05-01 |
Final Order |
2014-10-31 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on scaffolds more than 10 feet high were not protected from falling to the lower level: a) On or about 11/20/13 CSHOs observed four men working on and from two tubular welded rolling scaffolds with the walking/working platforms being 14 foot- 6 inches above the blacktop below with no fall protection systems in place, i.e. handrails along all open sides and ends of platform. L & J Stucco was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(g)(1), which was contained in OSHA inspection number 491718, citation number 1, Item number 4 and was affirmed as a final order on 01/14/2013, with respect to a workplace located at 197 West Old Country Road, Hicksville, NY 11801. |
|
|
334917184
|
0214700
|
2012-06-28
|
197 WEST OLD COUNTRY RD., HICKSVILLE, NY, 11801
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-06-28
|
Emphasis |
L: FALL
|
Case Closed |
2015-06-02
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2012-12-18 |
Abatement Due Date |
2012-12-24 |
Current Penalty |
600.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-01-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns. a) Worksite, Sunoco Gas Station - Employees were not wearing protective helmets while working under overhead stucco work; on or about 06/28/12. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Repeat |
Standard Cited |
19260451 B01 |
Issuance Date |
2012-12-18 |
Abatement Due Date |
2012-12-24 |
Current Penalty |
1800.0 |
Initial Penalty |
4000.0 |
Final Order |
2013-01-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) Worksite, Exterior - Employee was working on the second tier of a fabricated frame scaffold approximately 12ft above the ground. The employee was working on a single scaffolding plank; on or about 06/28/12. L & J Stucco was previously cited for a violation of this Occupational Safety and Health Standard, Its equivalent, or essentially similar standard 29 CFR 1926.451(b)(1) which was contained in OSHA inspection number 307611525, citation number 02, item number 001, issued on 08/11/08, and became final order on 09/03/08. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Repeat |
Standard Cited |
19260451 E01 |
Issuance Date |
2012-12-18 |
Abatement Due Date |
2012-12-24 |
Current Penalty |
1800.0 |
Initial Penalty |
4000.0 |
Final Order |
2013-01-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Worksite, Sunoco Gas Station - Employees were applying stucco to a commercial building while working off of a fabricated frame scaffold. The employees were climbing the crossbraces to gain access to the scaffold; on or about 6/28/12. L & J Stucco was previously cited for a violation of this Occupational Safety and Health Standard, Its equivalent, or essentially similar standard 29 CFR 1926.451(e)(1), which was contained in OSHA inspection number 307611525, citation number 01, item number 002, issued on 08/11/08, and became final order on 09/3/08. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01004 |
Citaton Type |
Repeat |
Standard Cited |
19260451 G01 |
Issuance Date |
2012-12-18 |
Abatement Due Date |
2012-12-24 |
Current Penalty |
1800.0 |
Initial Penalty |
4000.0 |
Final Order |
2013-01-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Worksite, Sunoco Gas Station - Employee was applying stucco to a single story commercial building while working on the second tier of a fabricated frame scaffold. The employee was not protected from falling approximately 12ft to the ground below; on or about 6/28/12. L & J Stucco was previously cited for a violation of this Occupational Safety and Health Standard, Its equivalent, or essentially similar standard 29 CFR 1926.451(g)(1) which was contained in OSHA inspection number 307611525, citation number 02, item number 002a, issued on 08/11/08, and became final order on 09/03/08. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
|
313431603
|
0215600
|
2011-07-19
|
63-36 99TH STREET, REGO PARK, NY, 11374
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-07-19
|
Emphasis |
L: FALL, S: RESIDENTIAL CONSTR, S: FALL FROM HEIGHT, N: SILICA
|
Case Closed |
2011-10-25
|
Related Activity
Type |
Complaint |
Activity Nr |
207619727 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260025 A |
Issuance Date |
2011-09-29 |
Abatement Due Date |
2011-10-04 |
Initial Penalty |
1800.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
|
313430217
|
0215600
|
2011-03-04
|
248-30 THEBES AVE, LITTLE NECK, NY, 11362
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-03-04
|
Emphasis |
L: FALL, S: FALL FROM HEIGHT
|
Case Closed |
2013-04-24
|
Related Activity
Type |
Referral |
Activity Nr |
200836773 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2011-05-06 |
Abatement Due Date |
2011-05-11 |
Current Penalty |
200.0 |
Initial Penalty |
1800.0 |
Contest Date |
2011-05-23 |
Final Order |
2012-01-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
01 |
|
Citation ID |
02001A |
Citaton Type |
Repeat |
Standard Cited |
19260451 B01 |
Issuance Date |
2011-05-06 |
Abatement Due Date |
2011-05-11 |
Current Penalty |
1000.0 |
Initial Penalty |
15000.0 |
Contest Date |
2011-05-23 |
Final Order |
2013-01-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
Citation ID |
02001B |
Citaton Type |
Repeat |
Standard Cited |
19260451 G01 |
Issuance Date |
2011-05-06 |
Abatement Due Date |
2011-05-11 |
Contest Date |
2011-05-23 |
Final Order |
2013-01-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
|
307612705
|
0215600
|
2009-01-15
|
1 POINT CRESCENT STREET, MALBA, NY, 11357
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2009-01-15
|
Emphasis |
L: FALL, S: FALL FROM HEIGHT, S: RESIDENTIAL CONSTR
|
Case Closed |
2009-01-15
|
Related Activity
Type |
Inspection |
Activity Nr |
307611525 |
|
|
307611525
|
0215600
|
2008-05-30
|
1 POINT CRESCENT STREET, MALBA, NY, 11357
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2008-06-02
|
Emphasis |
L: FALL, S: FALL FROM HEIGHT, S: RESIDENTIAL CONSTR
|
Case Closed |
2012-01-11
|
Related Activity
Type |
Complaint |
Activity Nr |
205902414 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 II |
Issuance Date |
2008-08-11 |
Abatement Due Date |
2008-08-14 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2008-08-11 |
Abatement Due Date |
2008-08-14 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260451 B01 I |
Issuance Date |
2008-08-11 |
Abatement Due Date |
2008-08-14 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
Citation ID |
02002A |
Citaton Type |
Repeat |
Standard Cited |
19260451 G01 |
Issuance Date |
2008-08-11 |
Abatement Due Date |
2008-08-14 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
Citation ID |
02002B |
Citaton Type |
Repeat |
Standard Cited |
19260454 B |
Issuance Date |
2008-08-11 |
Abatement Due Date |
2008-08-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
02003 |
Citaton Type |
Repeat |
Standard Cited |
19260452 C02 |
Issuance Date |
2008-08-11 |
Abatement Due Date |
2008-08-14 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
|
307610873
|
0215600
|
2008-02-27
|
208-01 NORTHERN BLVD, BAYSIDE, NY, 11361
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2008-02-27
|
Emphasis |
S: FALL FROM HEIGHT, L: FALL, S: COMMERCIAL CONSTR
|
Case Closed |
2008-04-10
|
Related Activity
Type |
Referral |
Activity Nr |
200834778 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2008-03-20 |
Abatement Due Date |
2008-03-26 |
Current Penalty |
800.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
|
309596864
|
0216000
|
2006-12-21
|
165 TUCKAHOE ROAD, YONKERS, NY, 10710
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2007-03-26
|
Emphasis |
L: FALL, S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT, S: STRUCK-BY
|
Case Closed |
2009-06-06
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2007-03-26 |
Abatement Due Date |
2007-03-29 |
Current Penalty |
900.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2007-03-26 |
Abatement Due Date |
2007-03-29 |
Current Penalty |
900.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260454 B02 |
Issuance Date |
2007-03-26 |
Abatement Due Date |
2007-03-29 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
10 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260452 C02 |
Issuance Date |
2007-03-26 |
Abatement Due Date |
2007-03-29 |
Current Penalty |
450.0 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
03 |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2007-03-26 |
Abatement Due Date |
2007-04-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19101200 G08 |
Issuance Date |
2007-03-26 |
Abatement Due Date |
2007-04-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
Citation ID |
02001C |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2007-03-26 |
Abatement Due Date |
2007-04-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
|