Name: | TRI COUNTY CONSOLIDATED INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 26 Mar 2007 (18 years ago) |
Entity Number: | 3494890 |
ZIP code: | 14423 |
County: | Livingston |
Place of Formation: | New York |
Address: | 3368 AVERILL ROAD, CALEDONIA, NY, United States, 14423 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 3368 AVERILL ROAD, CALEDONIA, NY, United States, 14423 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
070326001167 | 2007-03-26 | CERTIFICATE OF INCORPORATION | 2007-03-26 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
338981053 | 0213600 | 2013-03-26 | 5 MAIN STREET, GENESEO, NY, 14454 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Other |
Standard Cited | 19101200 E01 |
Issuance Date | 2013-04-26 |
Abatement Due Date | 2013-05-14 |
Current Penalty | 0.0 |
Initial Penalty | 1200.0 |
Final Order | 2013-05-23 |
Nr Instances | 1 |
Nr Exposed | 15 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59): a) Apartment building at 5 Main Street in Geneseo, no program had been developed or implemented for the employees potentially exposed to materials such as but not limited to gasoline and silicone sealant. ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19101200 G08 |
Issuance Date | 2013-04-26 |
Abatement Due Date | 2013-05-14 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-05-23 |
Nr Instances | 1 |
Nr Exposed | 15 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: (Construction Reference: 1926.59): a) Apartment building at 5 Main Street in Geneseo, no material safety data sheets were provided or made availableto the employees for materials such as but not limited to gasoline and silicone sealant. ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19101200 H01 |
Issuance Date | 2013-04-26 |
Abatement Due Date | 2013-05-14 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-05-23 |
Nr Instances | 1 |
Nr Exposed | 15 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59): a) Apartment building at 5 Main Street in Geneseo, no training had been provided for the employees potentially exposed to materials such as but not limited to gasoline and silicone sealant. ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002 |
Citaton Type | Other |
Standard Cited | 19260404 B01 I |
Issuance Date | 2013-04-26 |
Abatement Due Date | 2013-04-26 |
Current Penalty | 0.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-05-23 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) Apartment building, 5 Main Street, Geneseo, NY., employee using a Makita Circular Saw connected to permanent power by a series of extension cords and neither system was in place to protect the employees from electrical shocks. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2013-04-26 |
Abatement Due Date | 2013-04-26 |
Current Penalty | 1800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-05-23 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A safety harness with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a) Apartment building, 5 Main Street in Geneseo, employee observed working in a GenieZ-34/22 Aerial Lift without proper fall protection being provided, employee was wearing a harness without any lanyard being attached to the lift or "D" ring on the back of the employees harness. Employee was exposed to falls of approximately twenty (20) feet to the ground below. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260152 A01 |
Issuance Date | 2013-04-26 |
Abatement Due Date | 2013-04-30 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-05-23 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.152(a)(1): Containers other than approved metal safety cans were used for the handling and use of flammable liquids in quantities greater than one gallon: a) Outside apartment building at 5 Main Street in Geneseo, one (1) five gallon plastic container of gasoline used to refuel the compressor was not approved, container did not have a spring closing lid. ABATEMENT CERTIFICATION REQUIRED. |
Date of last update: 28 Mar 2025