Search icon

DOUG RUHS PLUMBING & HEATING INC.

Company Details

Name: DOUG RUHS PLUMBING & HEATING INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 04 Apr 2007 (18 years ago)
Date of dissolution: 29 Jun 2016
Entity Number: 3499397
ZIP code: 11934
County: Suffolk
Place of Formation: New York
Address: 37 HEWITT BLVD., CENTER MORICHES, NY, United States, 11934

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 37 HEWITT BLVD., CENTER MORICHES, NY, United States, 11934

History

Start date End date Type Value
2007-04-04 2023-06-29 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
DP-2154344 2016-06-29 DISSOLUTION BY PROCLAMATION 2016-06-29
070404000656 2007-04-04 CERTIFICATE OF INCORPORATION 2007-04-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340787654 0214700 2015-07-20 137 DUNE RD., WESTHAMPTON BEACH, NY, 11978
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2015-07-20
Case Closed 2015-07-28

Related Activity

Type Inspection
Activity Nr 1021147
Safety Yes
340211473 0214700 2015-01-23 137 DUNE RD., WESTHAMPTON BEACH, NY, 11978
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2015-01-23
Case Closed 2019-10-07

Related Activity

Type Inspection
Activity Nr 1020509
Safety Yes
Type Inspection
Activity Nr 1021743
Safety Yes
Type Inspection
Activity Nr 1020475
Safety Yes
Type Inspection
Activity Nr 992353
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2015-02-03
Abatement Due Date 2015-02-09
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-03-16
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite: Employees were carrying tools and materials from the first floor to the second floor of the residential building and were exposed to falls from an unprotected side approximately 9 ft. above the ground; on or about 1/23/15. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260502 B02
Issuance Date 2015-02-03
Abatement Due Date 2015-02-09
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-03-16
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high: a) Worksite: Employees carrying tools and materials from the basement to the first floor were using a walking/working surface that did not have intermediate structural members installed between the top edge of the guardrail system and the walking/working surface and were exposed to falls of up to and including approximately 9 ft.; on or about 1/23/15. b) Worksite: Employees carrying tools and materials from the first floor to the second floor were using a walking/working surface that did not have intermediate structural members installed between the top edge of the guardrail system and the walking/working surface and were exposed to falls of up to and including approximately 18 ft.; on or about 1/23/15. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261052 C04
Issuance Date 2015-02-03
Abatement Due Date 2015-02-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-16
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(4): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stairrail system and the stairway steps: a) Worksite: Employees carrying tools and materials from the basement to the first floor floor were using stairs that were not provided with intermediate structural members and were exposed to falls of up to and including approximately 9 ft.; on or about 1/23/15. b) Worksite: Employees carrying tools and materials from the first floor to the second floor were using stairs that were not provided with intermediate structural members and were exposed to falls of up to and including approximately 18 ft.; on or about 1/23/15. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 02001
Citaton Type Other
Standard Cited 19260100 A
Issuance Date 2015-02-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-16
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite - Employees working directly under ongoing overhead construction activities were not using head protection; on or about 1/23/15. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.

Date of last update: 28 Mar 2025