347728370
|
0213600
|
2024-09-03
|
272 HUNTINGTON AVE, BUFFALO, NY, 14214
|
|
Inspection Type |
Prog Other
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-09-03
|
Emphasis |
N: FALL
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B11 |
Issuance Date |
2024-09-10 |
Current Penalty |
9219.0 |
Initial Penalty |
9219.0 |
Final Order |
2024-10-07 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 09/03/2024 at a roof project located at 272 Huntington Ave in Buffalo, NY; employees were replacing the roof of a two story house. The roof had a 5 in 12 pitch and an eave height of approximately 20 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED Black Rock Roofing was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 1756723 , citation number 1, item number 1 and was affirmed as a final order on 07/09/2024, with respect to a workplace located at 1550 Delaware Ave, Buffalo, New York. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2024-09-10 |
Current Penalty |
2350.0 |
Initial Penalty |
2350.0 |
Final Order |
2024-10-07 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a) On or about 09/03/2024 at the roof area of the site, side rails of the extension ladder extended 1 feet above the upper landing surface being accessed. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
344237870
|
0213600
|
2019-08-05
|
106 NORWALK AVENUE, BUFFALO, NY, 14216
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-08-05
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-08-31
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B11 |
Issuance Date |
2019-09-26 |
Current Penalty |
8000.0 |
Initial Penalty |
22730.0 |
Contest Date |
2019-10-08 |
Final Order |
2020-03-23 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 8/5/19 at a roof project located at 101 Norwalk Avenue, Buffalo, New York; employees were placing shingles on the roof of a two story house. The roof had a 9 in 12 pitch and an eave height of approximately 20 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02002 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 I |
Issuance Date |
2019-09-26 |
Current Penalty |
1000.0 |
Initial Penalty |
3410.0 |
Contest Date |
2019-10-08 |
Final Order |
2020-03-23 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 8/5/19 at a roof project located at 101 Norwalk Avenue, Buffalo, New York; employees performing roofing activities from a ladder jack scaffold approximately 16 feet high and were not protected from falling by a personal fall arrest system. NO ABATEMENT CERTIFICATION REQUIRED Black Rock Roofing (1946), Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard which was contained in OSHA inspection number 1175820, citation number 1, item number 3b and was affirmed as a final order on 2/2/17, with respect to a workplace located at 1145 Hertel Avenue, Buffalo, New York. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19260100 A |
Issuance Date |
2019-09-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2019-10-08 |
Final Order |
2020-03-23 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 8/5/19 at a roof project located at 101 Norwalk Avenue, Buffalo, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
343923793
|
0213600
|
2019-04-10
|
379-381 MAIN STREET, TONAWANDA, NY, 14150
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-04-10
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-07-24
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260100 A |
Issuance Date |
2019-05-03 |
Current Penalty |
0.0 |
Initial Penalty |
4546.0 |
Contest Date |
2019-05-16 |
Final Order |
2019-09-16 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 4/10/19 at a roof project located at 379-381 Main Street, Tonawanda, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED Black Rock Roofing (1946), Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard which was contained in OSHA inspection number 1175820, citation number 1, item number 1a and was affirmed as a final order on 2/2/17, with respect to a workplace located at 1145 Hertel Avenue, Buffalo, New York. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 I |
Issuance Date |
2019-05-03 |
Current Penalty |
3000.0 |
Initial Penalty |
7578.0 |
Contest Date |
2019-05-16 |
Final Order |
2019-09-16 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 4/10/19 at a roof project located at 379-381 Main Street, Tonawanda, New York; employees performing roofing activities from a ladder jack scaffold approximately 16 feet high and were not protected from falling by a personal fall arrest system. NO ABATEMENT CERTIFICATION REQUIRED Black Rock Roofing (1946), Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard which was contained in OSHA inspection number 1175820, citation number 1, item number 3b and was affirmed as a final order on 2/2/17, with respect to a workplace located at 1145 Hertel Avenue, Buffalo, New York. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2019-05-03 |
Current Penalty |
3000.0 |
Initial Penalty |
7578.0 |
Contest Date |
2019-05-16 |
Final Order |
2019-09-16 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 4/10/19 at a roof project located at 379-381 Main Street, Tonawanda, New York; employees were placing shingles on the roof of a two story house. The roof had a 6 in 12 pitch and an eave height of approximately 18 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED Black Rock Roofing (1946), Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard which was contained in OSHA inspection number 1175820, citation number 1, item number 3a and was affirmed as a final order on 2/2/17, with respect to a workplace located at 1145 Hertel Avenue, Buffalo, New York. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260502 D16 III |
Issuance Date |
2019-05-03 |
Current Penalty |
3000.0 |
Initial Penalty |
6062.0 |
Contest Date |
2019-05-16 |
Final Order |
2019-09-16 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) On or about 4/10/19 at a roof project located at 379-381 Main Street, Tonawanda, New York; employees installing roofing were using ropes with rope grabs attached to their harnesses. The employees did not have their rope grabs adjusted or rigged to prevent free falls more than 6 feet. NO ABATEMENT CERTIFICATION REQUIRED Black Rock Roofing (1946), Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard which was contained in OSHA inspection number 1323987, citation number 1, item number 1 and was affirmed as a final order on 10/4/18, with respect to a workplace located at 11758 Clinton Street, Buffalo, New York. |
|
|
343239877
|
0213600
|
2018-06-19
|
1758 CLINTON STREET, BUFFALO, NY, 14206
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-06-19
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-12-13
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260502 D16 III |
Issuance Date |
2018-09-10 |
Current Penalty |
3696.0 |
Initial Penalty |
3696.0 |
Final Order |
2018-10-04 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) On or about 6/19/18 at a roof replacement project located at 1758 Clinton Street, Buffalo, New York; employees installing roofing were using ropes with rope grabs attached to their harnesses. The employees did not have their rope grabs adjusted or rigged to prevent free falls more than 6 feet. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
341758209
|
0213600
|
2016-09-06
|
1145 HERTEL AVENUE, BUFFALO, NY, 14216
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-09-06
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-10-16
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2016-09-21 |
Current Penalty |
2494.0 |
Initial Penalty |
4988.0 |
Contest Date |
2016-10-03 |
Final Order |
2017-02-02 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 09/06/16, on a jobsite at 1145 Hertel Ave., Buffalo, NY where a roof on a house was being replaced: Employees engaged in clean-up work on the ground, and/or working /walking/climbing access ladders in areas on the east and west sides of the house where they could be struck by debris, or other tools /materials that could fall or be thrown off the roof/scaffolds, were not wearing a hardhat. NO ABATEMENT DOCUMENTATION REQUIRED |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2016-09-21 |
Abatement Due Date |
2016-11-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-10-03 |
Final Order |
2017-02-02 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about 09/06/16, on a jobsite at 1145 Hertel Ave., Buffalo, NY where a roof on a house was being replaced: Employees engaged in construction work were not trained to recognize potential hazards on this type of jobsite including but not limited to falls from roofs, ladders, scaffolds and other surfaces, electrical hazards, unguarded tools/machines, and the need for personal protective equipment to protect them from various hazards. They also were not trained in the applicable OSHA regulations to control or eliminate these hazards. ABATEMENT DOCUMENTATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2016-09-21 |
Current Penalty |
1425.0 |
Initial Penalty |
2850.0 |
Contest Date |
2016-10-03 |
Final Order |
2017-02-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) On or about 09/06/16, at the front of a house at 1145 Hertel Ave., Buffalo, NY: An employee was exposed to a potential fall of approx. 15 ft. to the ground when he was walking on the perimeter ledge of the upper porch, outside of the porch railing, while using a portable air blower to clean dirt off the ledge. No fall protection system was utilized. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2016-09-21 |
Current Penalty |
2494.0 |
Initial Penalty |
4988.0 |
Contest Date |
2016-10-03 |
Final Order |
2017-02-02 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 09/06/16, on the east and west sides of the roof of a house at 1145 Hertel Ave., Buffalo, NY: Approx. seven employees engaged in roofing work were exposed to a fall of approx. 22 foot to the ground. The roof pitch was 10 in 12. There were a few slide guards (roofing Jacks) installed parallel to the roof eaves in some areas of the roof, but no fall protection system was utilized. NO ABATEMENT DOCUMENTATION REQUIRED |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 I |
Issuance Date |
2016-09-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-10-03 |
Final Order |
2017-02-02 |
Nr Instances |
2 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 09/06/16, at a house at 1145 Hertel Ave., Buffalo, NY: Employees were exposed to a potential fall of approx. 20 ft. to the ground when on the piks of ladder jack scaffolds erected in the driveways on the east and west sides of the house. No personal fall arrest system or other fall protection system was provided or used. NO ABATEMENT DOCUMENTATION REQUIRED |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19261053 B01 |
Issuance Date |
2016-09-21 |
Current Penalty |
3563.0 |
Initial Penalty |
7126.0 |
Contest Date |
2016-10-03 |
Final Order |
2017-02-02 |
Nr Instances |
3 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: Black Rock Roofing (1946), Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 964634, citation number 1, item number 4, and was affirmed as a final order on May 1, 2014, with respect to a workplace located at 78 Gardenwood Ln., Tonawanda, NY 14223. a) On or about 09/06/16, at the front of a house at 1145 Hertel Ave., Buffalo, NY: An employee was exposed to a potential fall of approx. 15 ft. to the ground when an extension ladder was used to access the upper porch of the house. The siderails of the ladder only extended approx. 18 inches above the roof edge. b) On or about 09/06/16, in the driveway on the east side of a house at 1145 Hertel Ave., Buffalo, NY: Employees engaged in roofing work were exposed to a potential fall of approx. 20 ft. to the ground when an extension ladder was used to access the pik on a ladder jack scaffold. The siderails of the ladder only extended approx. 21 inches above the pik. c) On or about 09/06/16, in the driveway on the west side of a house at 1145 Hertel Ave., Buffalo, NY: Employees engaged in roofing work were exposed to a potential fall of approx. 20 ft. to the ground when an extension ladder was used to access the pik on a ladder jack scaffold. The siderails of the ladder only extended approx. 18 inches above the pik. NO ABATEMENT DOCUMENTATION REQUIRED |
|
|
339646341
|
0213600
|
2014-03-25
|
78 GARDENWOOD LN., TONAWANDA, NY, 14223
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-03-25
|
Emphasis |
P: FALL, L: FALL
|
Case Closed |
2014-05-08
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2014-04-07 |
Abatement Due Date |
2014-05-08 |
Current Penalty |
940.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-04-25 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about 03/25/14, on jobsite at 2-story residential house at 78 Gardenwood Ln., Tonawanda, NY: Four employees engaged in construction work were not trained to recognize potential hazards on this type of jobsite including but not limited to falls from roofs, ladders, skylights, stairs & scaffolds, electrical hazards, unguarded tools/machines, fire hazards, and the need for personal protective equipment to protect them from various hazards. They also were not trained in the applicable OSHA regulations to control or eliminate these hazards. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260095 A |
Issuance Date |
2014-04-07 |
Abatement Due Date |
2014-04-15 |
Current Penalty |
940.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-04-25 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a) On or about 03/25/14, on the main roof of a 2-story house at 78 Gardenwood Ln., Tonawanda, NY: Four employees engaged in roofing work were not provided with, nor wearing eye protection while using or working in the vicinity where an air powered Hitachi Model NV 45AB2, 1 3/4" Coil Nail Gun was being used to fasten roofing shingles. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2014-04-07 |
Current Penalty |
940.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-04-25 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. a) On or about 03/25/14, on the main roof of a 2-story house at 78 Gardenwood Ln., Tonawanda, NY: Four employees engaged in roofing work were exposed to a potential fall of approx. 18 ft. because no fall protection system was utilized. The roof pitch was 4 in 12. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2014-04-07 |
Current Penalty |
826.0 |
Initial Penalty |
1360.0 |
Final Order |
2014-04-25 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 03/25/14, on the front side of a 2-story residential house at 78 Gardenwood Ln., Tonawanda, NY: Four employees engaged in roofing work were exposed to a potential fall of approx. 18 ft. to the ground when an extension ladder was used to access the roof from the ground. The siderails of the ladder only extended approx. 16 inches above the roof edge. b) On or about 03/25/14, on the Back side of a 2-story residential house at 78 Gardenwood Ln., Tonawanda, NY: Employees engaged in roofing work were exposed to a potential fall of approx. 11 ft. to the ground when an extension ladder was used to access the roof from the ground. The siderails of the ladder only extended approx. 18 inches above the roof edge. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
312607369
|
0213600
|
2008-10-29
|
247 GEORGIA STREET, BUFFALO, NY, 14201
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2008-10-29
|
Emphasis |
S: RESIDENTIAL CONSTR, L: FALL, S: FALL FROM HEIGHT
|
Case Closed |
2009-05-15
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 I |
Issuance Date |
2008-11-14 |
Abatement Due Date |
2008-11-19 |
Current Penalty |
750.0 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260452 K01 |
Issuance Date |
2008-11-14 |
Abatement Due Date |
2008-11-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2008-11-14 |
Abatement Due Date |
2008-11-19 |
Current Penalty |
750.0 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2008-11-14 |
Abatement Due Date |
2008-12-17 |
Current Penalty |
750.0 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261051 A |
Issuance Date |
2008-11-14 |
Abatement Due Date |
2008-11-19 |
Current Penalty |
450.0 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
|