Name: | 326 BUTLER ST. MAINTENANCE INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Inactive |
Date of registration: | 13 Jun 2007 (18 years ago) |
Date of dissolution: | 27 Jul 2011 |
Entity Number: | 3530430 |
ZIP code: | 11217 |
County: | Kings |
Place of Formation: | New York |
Address: | 326 BUTLER STREET, BROOKLYN, NY, United States, 11217 |
Contact Details
Phone +1 718-855-4353
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 326 BUTLER STREET, BROOKLYN, NY, United States, 11217 |
Number | Status | Type | Date | End date |
---|---|---|---|---|
1260040-DCA | Inactive | Business | 2007-06-27 | 2009-06-30 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
DP-2033077 | 2011-07-27 | DISSOLUTION BY PROCLAMATION | 2011-07-27 |
070613000574 | 2007-06-13 | CERTIFICATE OF INCORPORATION | 2007-06-13 |
Fee Sequence Id | Fee type | Status | Date | Amount | Description |
---|---|---|---|---|---|
841281 | FINGERPRINT | INVOICED | 2007-06-27 | 75 | Fingerprint Fee |
841282 | TRUSTFUNDHIC | INVOICED | 2007-06-27 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
841280 | LICENSE | INVOICED | 2007-06-27 | 125 | Home Improvement Contractor License Fee |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339587743 | 0215600 | 2014-02-14 | 166-38 14TH AVENUE, WHITESTONE, NY, 11357 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 903379 |
Safety | Yes |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2013-04-25 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2016-10-20 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2013-09-19 |
Current Penalty | 1020.0 |
Initial Penalty | 1020.0 |
Final Order | 2013-10-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about April 25, 2013- at the site of 166-38 14 Ave Whitestone, NY 11357. Employee exposed to overhead hazard from Iron fence sections being installed 3 - feet, 9 inches over head. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2013-09-19 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-10-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about April 25, 2013- at the site of 166-38 14 Ave Whitestone, NY 11357. Employer did not provide fall protection for employee 8-feet, 9-inches above the next lower level while Installing decorative fence. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2013-09-19 |
Abatement Due Date | 2013-10-16 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-10-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about April 25, 2013- at the site of 166-38 14 Ave Whitestone, NY 11357. The Employer could not identify the need for fall protection when employees were exposed to falls of up to 8-feet, 9-inches. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19261053 B06 |
Issuance Date | 2013-09-19 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-10-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS) a) On or about April 25, 2013- at the site of 166-38 14 Ave Whitestone, NY 11357. Employee accessing a 5-foot ladder with spreader bars not lock in position. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2013-09-19 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-10-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On or about April 25, 2013-at the site of 166-38 14 Ave Whitestone, NY 11357 Employee standing on the top of a stepladder to install an iron fence on a balcony. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |