341847697
|
0213600
|
2016-10-11
|
5933 MAIN STREET, WILLIAMSVILLE, NY, 14221
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-10-11
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2016-11-21
|
Related Activity
Type |
Inspection |
Activity Nr |
1183822 |
Safety |
Yes |
|
|
341028140
|
0213600
|
2015-10-27
|
2412 SENECA STREET, WEST SENECA, NY, 14224
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-10-29
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-11-21
|
Related Activity
Type |
Inspection |
Activity Nr |
1102833 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1102865 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2015-11-17 |
Current Penalty |
2400.0 |
Initial Penalty |
2400.0 |
Final Order |
2015-12-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated. a) On or about 10/27/15, at the front of the building, outside of the interior false roof area above the lobby area at the Ebenezer Square Apartment Building under construction , 2412 Seneca St., West Seneca , NY: Two employees were exposed to potential fall of approx. 12 ft. while installing plywood sheeting on the outside of the building from the elevated "basket" of a JLG aerial lift. Both of the employees were wearing a full body harness, but neither of the employees was tethered to the boom or basket of the lift. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2015-11-17 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2015-12-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) On or about 10/27/15, at the front of the building, outside of the interior false roof area above the lobby area at the Ebenezer Square Apartment Building under construction , 2412 Seneca St., West Seneca , NY: One employee engaged in framing work was exposed to a fall of approx. between 11 ft. and 12 ft. respectively, from unguarded edges on the front and back sides of the interior false roof area. The employee actually went through the unguarded opening and climbed into the elevated basket of an aerial lift that was just outside the area. The employee was wearing a full body harness, but was not tethered to an anchor point. No other fall protection system was utilized. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
339385437
|
0213600
|
2013-09-04
|
ROCK OAK MODEL HOME CENTER KINGS CROSS AVENUE, CLARENCE, NY, 14031
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-09-05
|
Case Closed |
2014-11-26
|
Related Activity
Type |
Complaint |
Activity Nr |
850407 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2013-09-16 |
Abatement Due Date |
2013-10-17 |
Current Penalty |
600.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-10-25 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about 09/04/13, at residential construction site on Kings Cross Ave.,in the Rock Oak Model Home Center, Clarence, NY: Employees engaged in construction work were not trained to recognize potential hazards on this type of jobsite including but not limited to falls from roofs, ladders, stairs & scaffolds, electrical hazards, unguarded tools/machines, fire hazards, and the need for personal protective equipment to protect from various hazards. They also were not trained in the applicable OSHA regulations to control or eliminate these hazards. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260028 A |
Issuance Date |
2013-09-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-10-25 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions: a) On or about 09/04/13, in the garage at residential construction site on Kings Cross Ave.,in the Rock Oak Model Home Center, Clarence, NY: Employees were provided safety glasses & hardhats as required under 29 CFR 1926.95(a), but were not using eye protection and hardhats while operating and/or working in the vicinity of where a Bostitch Air Powered Nail Gun was being used. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 I |
Issuance Date |
2013-09-16 |
Current Penalty |
600.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-10-25 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) On or about 09/04/13, in the garage at residential construction site on Kings Cross Ave.,in the Rock Oak Model Home Center, Clarence, NY: A DeWalt Model DWE575 Circular Saw was connected to 120 volt-ac power via a series of extension cords that included a DeWalt portable radio/power station. The first cord in the series was plugged into a wall receptacle inside the house under construction. No GFCI or assured equipment grounding program was being used. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2013-09-16 |
Current Penalty |
0.0 |
Initial Penalty |
1020.0 |
Final Order |
2013-10-25 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 09/04/13, in the garage at residential construction site on Kings Cross Ave.,in the Rock Oak Model Home Center, Clarence, NY: A black extension cord supplied power to a DeWalt Model DWE575 Circular Saw. This extension cord was plugged into one of the three 120 volt-ac receptacles on a DeWalt portable radio/power station. The plug on the DeWalt portable radio/power station lacked a grounding prong, so all three receptacles on the power station were ungrounded. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19261053 B04 |
Issuance Date |
2013-09-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-10-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about 09/04/13, in the garage at residential construction site on Kings Cross Ave.,in the Rock Oak Model Home Center, Clarence, NY: An Employee stood on the second step of an unopened stepladder laid against the garage wall while using an air powered nail gun. NO ABATEMENT CERTIFICATION REQUIRED |
|
|