345729040
|
0213600
|
2022-01-14
|
190 EAST MAIN STREET, ROCHESTER, NY, 14604
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2022-01-14
|
Emphasis |
L: GUTREH, P: GUTREH
|
Case Closed |
2022-03-31
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260034 B |
Issuance Date |
2022-03-04 |
Current Penalty |
1100.0 |
Initial Penalty |
1796.0 |
Final Order |
2022-03-18 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.34(b):Exits and access to exits were not marked by a readily visible sign: a) On or about 01/14/2022, at the Glenny Building (under renovation), located on 190 East Main Street, in Rochester, New York, the employer did not enforce the use of exit signs to allow for safe and unobstructed egress from the basement of the building. Employees working in the basement did not have visible exit signs to provide for a safe path of escape from a fire or other emergency. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
345636518
|
0213600
|
2021-11-05
|
44 ELTON STREET, ROCHESTER, NY, 14607
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-11-05
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2023-01-18
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2022-01-10 |
Current Penalty |
0.0 |
Initial Penalty |
2653.0 |
Contest Date |
2022-01-25 |
Final Order |
2022-10-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) On or about 11/05/2021, at 39 Russell Street, in Rochester, New York, the employer did not enforce the use of fall protection, during the repair and sealing process of existing roof. Employee(s) working without fall protection were exposed to falling 30 feet to lower levels. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
343202701
|
0213600
|
2018-06-04
|
39 RUSSELL STREET, ROCHESTER, NY, 14607
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-06-04
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2019-07-29
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2018-08-22 |
Current Penalty |
0.0 |
Initial Penalty |
2670.0 |
Contest Date |
2018-09-17 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) On or about 06/04/18, during renovations of "The Factory" located at 36 - 39 Russell Street, in Rochester, New York, workers performing renovation work for residential occupancy, were not protected from falling through an open window frame with fall protection systems as noted in 1926.501(b)(1). The indoor floor surface to lower window sill measured 34 inches and the outside measured 16 feet from lower window sill to ground level. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260150 A04 |
Issuance Date |
2018-08-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2018-09-17 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.150(a)(4): One piece of firefighting equipment was not inspected and maintained in operating condition. (a) On or about 06/04/18, during renovations of "The Factory" located at 36 - 39 Russell Street, in Rochester, New York, during renovation work on the 2nd floor a fire extinguisher (available for use) had been discharged and not taken out of service. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
340910843
|
0213600
|
2015-09-09
|
33 RUSSELL STREET, ROCHESTER, NY, 14607
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-09-09
|
Emphasis |
L: GUTREH, P: GUTREH
|
Case Closed |
2016-04-26
|
Related Activity
Type |
Inspection |
Activity Nr |
1091063 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260152 F01 |
Issuance Date |
2015-09-25 |
Current Penalty |
0.0 |
Initial Penalty |
1200.0 |
Contest Date |
2015-10-20 |
Final Order |
2016-04-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.152(f)(1): Flammable liquids were not kept in closed containers when not actually in use: a) On or about 09/09/15, at The Factory, a multi-use facility under development, located at 33 Russell Street, in Rochester, New York, a portable plastic container, containing gasoline, was not closed when not in use, allowing flammable vapors to escape, where ignition sources such as; electrical power tools and propane burner were in close proximity (within 5 feet). NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260405 B03 I |
Issuance Date |
2015-09-25 |
Current Penalty |
0.0 |
Initial Penalty |
1200.0 |
Contest Date |
2015-10-20 |
Final Order |
2016-04-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(b)(3)(i): Boxes shall provide a complete enclosure for the contained conductors or cables. a) On or about 09/09/15, The Factory, a multi-use facility, under development, located at 33 Russell Street, in Rochester, New York, a receptacle in use to feed various electrical equipment; including power tools, had a bent cover plate exposing live conductors. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260404 B01 III C |
Issuance Date |
2015-09-25 |
Current Penalty |
0.0 |
Initial Penalty |
1200.0 |
Contest Date |
2015-10-20 |
Final Order |
2016-04-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(iii)(C): Where an assured equipment grounding conductor program was being utilized, the employer did not ensure that each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were not visually inspected fofore each day's use for external defects, such as deformed or missing pins or insulation damage, and for indicationsof possible internal damage: a) On or about 09/09/15, at The Factory, a multi-use facility, under development and located at 33 Russell Street, in Rochester, New York, a cord set in use to feed power tools, was missing its ground pin. NO ABATEMENT CERTIFICATION REQUIRED |
|
|