Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-05-07
|
Emphasis |
L: LOCALTARG, P: LOCALTARG
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260300 B01 |
Issuance Date |
2024-10-25 |
Current Penalty |
2250.0 |
Initial Penalty |
3457.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use. Location: 1370 Dean Street, Brooklyn, NY. On or about 5/7/2024, a) A 10" table saw was used without the blade guard installed. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260403 B02 |
Issuance Date |
2024-10-25 |
Current Penalty |
1800.0 |
Initial Penalty |
2765.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification. Location: 1370 Dean Street, Brooklyn, NY. On or about 5/7/2024, a) A 4"x4" metal box installed with duplex outlets was used not in accordance with instructions included in the listing, labeling, or certification. It was left on the floor without being mounted. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260403 I02 I |
Issuance Date |
2024-10-25 |
Current Penalty |
3150.0 |
Initial Penalty |
4839.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. Location: 1370 Dean Street, Brooklyn, NY. On or about 5/7/2024, a) Three energized breaker panels were not provided with a cover. Employees were exposed to accidental contacts with the live electrical parts of 110-volts. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260405 J01 I |
Issuance Date |
2024-10-25 |
Current Penalty |
1800.0 |
Initial Penalty |
2765.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(j)(1)(i): Fixtures, lamp holders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact. Location: 1370 Dean Street, Brooklyn, NY. On or about 5/7/2024, a) Two duplex outlet receptacles were used with receptacle cover plate missing. Employee was exposed to the live internal bare conductors. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2024-10-25 |
Current Penalty |
1800.0 |
Initial Penalty |
2765.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: 1370 Dean Street, Brooklyn, NY. On or about 5/7/2024, a) The stairway opening on the ground floor was not installed with guardrails or protected by any other means. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 I |
Issuance Date |
2024-10-25 |
Current Penalty |
1420.0 |
Initial Penalty |
2074.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail. Location: 1370 Dean Street, Brooklyn, NY. On or about 5/7/2024, a) Two flights of stairs with both sides closed and measuring approximately 4 ft. wide with 13 risers for one and 20 risers for the other, did not have at least one handrail installed. |
|
|