346502172
|
0213100
|
2023-02-14
|
10 KATHERINE CT., BALLSTON LAKE, NY, 12019
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-02-14
|
Emphasis |
L: FALL
|
Related Activity
Type |
Referral |
Activity Nr |
1997497 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19260451 B05 I |
Issuance Date |
2023-08-07 |
Abatement Due Date |
2024-05-16 |
Current Penalty |
4688.0 |
Initial Penalty |
4688.0 |
Contest Date |
2023-08-28 |
Final Order |
2024-05-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length extended over its support more than 12 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end: a) Worksite - On or about February 7, 2023 and at times prior thereto, an employee was working from a ladder jack scaffold approximately 18 feet above the ground. The platform extended more than 12 inches on both ends of the support brackets. The platform tipped causing the employee to fall to the ground. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19260451 E01 |
Issuance Date |
2023-08-07 |
Abatement Due Date |
2024-05-16 |
Current Penalty |
0.0 |
Initial Penalty |
4688.0 |
Contest Date |
2023-08-28 |
Final Order |
2024-05-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a) Worksite - On or about February 7, 2023 and at times prior thereto, an employee was preparing to install roofing material from the platform of a ladder jack scaffold approximately 18-feet above the ground below. The employee did not have adequate access to the ladder jack scaffold platform. |
|
Citation ID |
01001C |
Citaton Type |
Other |
Standard Cited |
19260451 G01 I |
Issuance Date |
2023-08-07 |
Abatement Due Date |
2024-05-16 |
Current Penalty |
0.0 |
Initial Penalty |
4688.0 |
Contest Date |
2023-08-28 |
Final Order |
2024-05-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) Worksite - On or about February 7, 2023 and at times prior thereto, an employee was working from the platform of a ladder jack scaffold approximately 18 feet above the ground without the use of fall protection. |
|
Citation ID |
01004 |
Citaton Type |
Other |
Standard Cited |
19260452 K05 |
Issuance Date |
2023-08-07 |
Abatement Due Date |
2024-05-16 |
Current Penalty |
0.0 |
Initial Penalty |
2679.0 |
Contest Date |
2023-08-28 |
Final Order |
2024-05-16 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(k)(5): Scaffold platforms were bridged on to another: a) Worksite, Northeast side of home - On or about February 7, 2023 and at times prior thereto, the ladder jack scaffolds were bridged one to another, exposing employees to fall hazards approximately 10 feet. |
|
Citation ID |
01005 |
Citaton Type |
Other |
Standard Cited |
19260501 B13 |
Issuance Date |
2023-08-07 |
Abatement Due Date |
2024-05-16 |
Current Penalty |
4688.0 |
Initial Penalty |
4688.0 |
Contest Date |
2023-08-28 |
Final Order |
2024-05-16 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite - On or about February 7, 2023 and at times prior thereto, employees were working from the residential roof approximately 18 feet above the ground and did not have fall protection. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2023-08-07 |
Current Penalty |
3349.0 |
Initial Penalty |
3349.0 |
Contest Date |
2023-08-28 |
Final Order |
2024-05-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye: a) Worksite - On or about February 7, 2023, an employer did not notify OSHA within 24 hours of a work-related incident was hospitalized following a fall during roofing activities. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19260503 B01 |
Issuance Date |
2023-08-07 |
Abatement Due Date |
2024-05-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2023-08-28 |
Final Order |
2024-05-16 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: a) Worksite - On or about February 7, 2023 and at times prior thereto, the employer did not keep a written certification to verify that all employees exposed to fall hazards had received training. |
|
|
340846955
|
0213100
|
2015-08-13
|
1226 LOUDON ROAD BUILDING 17-23, LATHAM, NY, 12110
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-08-13
|
Emphasis |
L: FALL, P: LOCALTARG, L: LOCALTARG
|
Case Closed |
2016-06-20
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2015-08-19 |
Current Penalty |
500.0 |
Initial Penalty |
2200.0 |
Contest Date |
2015-09-28 |
Final Order |
2016-06-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: (a) Front of the building, upper roof, On or about August 13, 2015 - the ladder jack scaffold system was not equipped with a separate access ladder. Scaffold deck to the ground elevation was approximately 18 feet, 3 inches. (b) Front of the building, lower roof, on or about August 13, 2015 - the ladder jack scaffold system was not equipped with a separate access ladder. Scaffold deck to the ground elevation was approximately 8 feet, 9 inches. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260502 D16 III |
Issuance Date |
2015-08-19 |
Current Penalty |
500.0 |
Initial Penalty |
2200.0 |
Contest Date |
2015-09-28 |
Final Order |
2016-06-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: (a) Front of the building, On or about August 13, 2015 - the employee that was installing roof shingles and brackets was attached to a vertical lifeline rope grab system that had considerable slack, creating a fall hazard that would exceed 6 feet. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260451 G01 I |
Issuance Date |
2015-08-19 |
Current Penalty |
1000.0 |
Initial Penalty |
11000.0 |
Contest Date |
2015-09-28 |
Final Order |
2016-06-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: (a) Front of the building, On or about August 13, 2015 - no fall protection was being used for the employee that was installing roof shingles and brackets, working from a ladder jack scaffold system. Scaffold deck to ground elevation was approximately 18 feet, 3 inches. McAvoy Development , LLC., was previously cited for a repeat violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.451(g)(1)(I), which was contained in OSHA inspection number 967349, citation number 2, item number 1, and was affirmed as a final order on January 14, 2015, with respect to a workplace located at 356 Westwoods Court, Schenectady, NY 12303. McAvoy Development , LLC., was previously cited for a repeat violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.451(g)(1)(I), which was contained in OSHA inspection number 952009, citation number 1, item number 1c, and was affirmed as a final order on March 7, 2014, with respect to a workplace located at 33/14 Widgeon Way, Waterford, NY 12188. |
|
|
339673493
|
0213100
|
2014-04-12
|
356 WESTWOODS CT, SCHENECTADY, NY, 12303
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-04-12
|
Emphasis |
L: FALL, L: LOCALTARG, N: SVEP, P: LOCALTARG
|
Case Closed |
2016-07-07
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2014-04-16 |
Abatement Due Date |
2015-02-16 |
Current Penalty |
500.0 |
Initial Penalty |
2800.0 |
Contest Date |
2014-05-09 |
Final Order |
2015-01-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a). On or about 4/12/14, at 356 Westwoods Ct, Schenectady, NY 12303. An employee, delivering roofing material, was using a ladder to climb onto or off of the roof. The extension ladder was used to access the second floor roof, and it's side rails did not extend at least three feet above the roof. Employees were exposed to fall hazards of approximately 22 feet. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260451 G01 I |
Issuance Date |
2014-04-16 |
Abatement Due Date |
2015-02-16 |
Current Penalty |
1500.0 |
Initial Penalty |
5600.0 |
Contest Date |
2014-05-09 |
Final Order |
2015-01-14 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold were not protected by a personal fall arrest system: a). On or about 4/12/14, at 356 Westwoods Ct, Schenectady, NY 12303. Employees were working from a ladder jack scaffold without fall protection exposing them to fall hazards of up to 18 feet. McEvoy Development, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(g)(1)(i), which was contained in OSHA inspection number 952009, citation number 1, item number 1,c and was affirmed as a final order on 3/7/14, with respect to a workplace located at 33/14 Widgeon Way Waterford, NY 12188. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-04-16 |
Abatement Due Date |
2015-02-03 |
Current Penalty |
1500.0 |
Initial Penalty |
5600.0 |
Contest Date |
2014-05-09 |
Final Order |
2015-01-14 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system nor were employee(s) provided with an alternative fall protection measure under provision 1926.501 (b): a). On or about 4/12/14, at 356 Westwoods Ct, Schenectady, NY 12303. Employees were installing felt papering shingles on a new 10 on 12 pitch roof without conventional fall protection. Employees were exposed to fall hazards of approximately 18 feet. McAvoy Development, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 952009, citation number 1, item number 1,d and was affirmed as a final order on 3/7/14, with respect to a workplace located at 33/14 Widgeon Way, Waterford, NY 12188. |
|
|
339669822
|
0213100
|
2014-04-10
|
CANTERBURY CROSSING STACEY COURT -- BLDG 3., LATHAM, NY, 12110
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-04-10
|
Emphasis |
L: FALL, N: CTARGET, P: FALL
|
Case Closed |
2015-09-27
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 B04 |
Issuance Date |
2014-04-30 |
Current Penalty |
250.0 |
Initial Penalty |
1600.0 |
Contest Date |
2014-05-09 |
Final Order |
2015-01-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(4): Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm). (a) North end of building above garage, on or about 4/10/14: 24 foot aluminum pick did not have sufficient bearing surface at the exterior wall cleat to exend over the centerline of it's support at least 6 inches, exposing employee to a fall hazard of 4 to 14 feet. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2014-04-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2014-05-09 |
Final Order |
2015-01-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. (a) North end of building above garage, on or about 4/10/14: Carpenter's bracket scaffold system (wood brackets and aluminum picks) was not inspected by a competent person prior to use. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 III |
Issuance Date |
2014-04-30 |
Abatement Due Date |
2015-01-24 |
Current Penalty |
250.0 |
Initial Penalty |
2000.0 |
Contest Date |
2014-05-09 |
Final Order |
2015-01-14 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used. (a) At the jobsite, during roofing operations, on or about 4/10/14: Employees were exposed to fall hazards of 10 to approximately 25 feet without training in proper use of fall protection system(s), including but not limited to installation and use of the vertical lifeline system and use of associated body harness and rope-grab. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260020 B02 |
Issuance Date |
2014-04-30 |
Abatement Due Date |
2015-01-24 |
Current Penalty |
500.0 |
Initial Penalty |
3200.0 |
Contest Date |
2014-05-09 |
Final Order |
2015-01-14 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s) (a) At the jobsite, prior to and/or during roofing work, on or about 4/10/14: Inspection of the jobsite, tools, and equipment, including but not limited to: ladders, scaffolding, fall protection gear, tools, and personal protective equipment, were not conducted by a competent person designated by the employer. McAvoy Development LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.20(b)(2), which was contained in OSHA inspection number 952009, citation number 1, item number 1(a) and was affirmed as a final order on 3/7/14, with respect to a workplace located at 13/14 Widgeon Way, Waterford, NY 12188. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19260102 A01 |
Issuance Date |
2014-04-30 |
Current Penalty |
500.0 |
Initial Penalty |
2400.0 |
Contest Date |
2014-05-09 |
Final Order |
2015-01-14 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. (a) At the jobsite, during roofing work, on or about 4/10/14: Employees were not using protective eyewear during operation of pneumatic nail guns and when using hammers. McAvoy Development LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.102(a)(1), which was contained in OSHA inspection number 952009, citation number 1 , item number 1(b) and was affirmed as a final order on 3/7/14, with respect to a workplace located at 13/14/ Widgeon Way, Waterford, NY 12188. |
|
|
339520090
|
0213100
|
2013-12-11
|
13/14 WIDGEON WAY, WATERFORD, NY, 12188
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-12-11
|
Emphasis |
L: FALL
|
Case Closed |
2014-03-18
|
Related Activity
Type |
Complaint |
Activity Nr |
864510 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260020 B02 |
Issuance Date |
2014-02-13 |
Abatement Due Date |
2014-02-24 |
Current Penalty |
1500.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-03-07 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person: (a) At the jobsite, on or prior to December 11, 2013: The jobsite was not inspected by a competent person capable of identifying and correcting hazards associated with residential construction work. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2014-02-13 |
Abatement Due Date |
2014-02-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a) 33/14 Widgeon Way Waterford, NY 12188; On or about 12/11/13, Employees were using pneumatic nail guns without eye protection. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2014-02-13 |
Abatement Due Date |
2014-02-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. b) a) 33/14 Widgeon Way Waterford, NY 12188; On or about 12/11/13, Employees were working from a ladder jack scaffold without guard rails exposing them to fall hazards of up to 14 feet. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-02-13 |
Abatement Due Date |
2014-02-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-07 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 33/14 Widgeon Way Waterford, NY 12188; On or about 12/11/13, Employees were installing asphalt shingles on a new roof without conventional fall protection. Employees were exposed to fall hazards of approximately 14 feet. |
|
Citation ID |
01001E |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2014-02-13 |
Abatement Due Date |
2014-02-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-07 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) 33/14 Widgeon Way Waterford, NY 12188; On or about 12/11/13, Employees were accessing two sections of ladder jack scaffolding using ladders that did not extend at least 3 feet above the landing exposing them to fall hazards of up to 14 feet. |
|
|