Search icon

DELCID HOME IMPROVEMENT CONTRACTOR CORP.

Company Details

Name: DELCID HOME IMPROVEMENT CONTRACTOR CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 15 Aug 2007 (18 years ago)
Entity Number: 3556359
ZIP code: 11590
County: Nassau
Place of Formation: New York
Address: 215 BROOK STREET, WESTBURY, NY, United States, 11590
Principal Address: 215 BROOK ST, WESTBURY, NY, United States, 11590

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 215 BROOK STREET, WESTBURY, NY, United States, 11590

Chief Executive Officer

Name Role Address
LEAVIN DELCID Chief Executive Officer 215 BROOK ST, WESTBURY, NY, United States, 11590

History

Start date End date Type Value
2007-08-15 2008-02-14 Address 211 BROOK STREET, WESTBURY, NY, 11590, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
090807002404 2009-08-07 BIENNIAL STATEMENT 2009-08-01
080214000656 2008-02-14 CERTIFICATE OF CHANGE 2008-02-14
070815000508 2007-08-15 CERTIFICATE OF INCORPORATION 2007-08-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339642035 0214700 2014-03-21 1021 THOMAS AVE., BALDWIN, NY, 11510
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-03-21
Emphasis L: FALL, L: SANDY, P: FALL
Case Closed 2018-12-04

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2014-04-07
Abatement Due Date 2014-04-11
Current Penalty 600.0
Initial Penalty 1200.0
Final Order 2014-04-23
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a) worksite - An employee installing shingles with a pneumatic nail gun was not using eye protection; on or about 03/21/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2014-04-07
Current Penalty 600.0
Initial Penalty 1200.0
Final Order 2014-04-23
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite - Employees working directly under ongoing roofwork were not wearing head protection; on or about 03/21/2013. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-04-07
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2014-04-23
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) worksite - Employees working on an approximate 10-12 pitch roof, approximately 22 feet above the ground were not protected from falling; on or about 03/21/14. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-04-07
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2014-04-23
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) worksite - Employees were using an unsecured ladder to gain access to the roof. The ladder side rails were approximately 4 inches above the upper landing; on or about 03/21/14. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.

Date of last update: 28 Mar 2025

Sources: New York Secretary of State