Search icon

EQ PACIFIC CONSTRUCTION INC.

Company Details

Name: EQ PACIFIC CONSTRUCTION INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 10 Sep 2007 (18 years ago)
Date of dissolution: 27 Jul 2011
Entity Number: 3565857
ZIP code: 11415
County: Queens
Place of Formation: New York
Address: 84-72 130TH STREET, SUITE 1, KEW GARDENS, NY, United States, 11415

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 84-72 130TH STREET, SUITE 1, KEW GARDENS, NY, United States, 11415

Filings

Filing Number Date Filed Type Effective Date
DP-2038541 2011-07-27 DISSOLUTION BY PROCLAMATION 2011-07-27
070910000657 2007-09-10 CERTIFICATE OF INCORPORATION 2007-09-10

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
338172653 0214700 2013-01-07 184 GORDON RD., VALLEY STREAM, NY, 11581
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-01-07
Emphasis L: FALL
Case Closed 2017-12-18

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2013-02-12
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2013-05-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite, Exterior - Employees were not wearing protective helmets and were exposed to being struck by overhead materials and tools while walking below overhead siding work; on or about 01/07/13. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B02 I
Issuance Date 2013-02-12
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-05-09
Nr Instances 2
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2)(i): Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold was not at least 12 inches (30 cm) wide a) Worksite, Front of home - Employee was installing siding while working from the platform of a pump jack scaffold with a single 2x8 inch plank, approximately 11ft above the ground; on or about 01/07/13. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F06
Issuance Date 2013-02-12
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-05-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. a) Worksite, side of home - An employee was installing siding and aluminum caping while walking and working on a ladder jack scaffold. The employee was working less than 2ft away from an energized secondary line; on or about 01/07/13. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2013-02-12
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-05-09
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) Worksite, side of home - An employee was installing siding and caping to a two story residential home while working from the platform of a ladder jack scaffold resting on a garbage can; on or about 01/07/13. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2013-02-12
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-05-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Worksite, Front of home - Employee was exposed to falling while working from the platform of a pump jack scaffold approximately 11ft from the ground below; on or about 01/07/13. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-02-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-05-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b) a) Worksite, Front of home - Employee was installing siding to a two story residential home while working from a 6-12 pitch roof approximately 11ft above the ground without fall protection; on or about 01/07/13. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.