Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-07-08
|
Emphasis |
L: FALL
|
Case Closed |
2018-05-21
|
Related Activity
Type |
Referral |
Activity Nr |
999055 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2015-07-15 |
Abatement Due Date |
2015-07-27 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-08-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: On or about July 8, 2015- Job site at 214-11 16th Ave, Bayside, NY 11360 The employer permitted their employees to work on a ladder scaffold, approximately 25 feet above the next lower level, without fall protection. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $ 1,000.00 AS PER 29 CFR 1903.19. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260452 K01 |
Issuance Date |
2015-07-15 |
Abatement Due Date |
2015-07-27 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-08-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(k)(1): Platforms exceeded a height of 20 feet (6.1 m) On or about July 8, 2015- Job site at 214-11 16th Ave, Bayside, NY 11360 The employer permitted their employees to work on a ladder scaffold approximately 25 feet above the next lower level. The maximum permissible platform height for this scaffold is 20 feet. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $ 1,000.00 AS PER 29 CFR 1903.19. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260452 K04 |
Issuance Date |
2015-07-15 |
Abatement Due Date |
2015-07-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(k)(4): Ladders used to support ladder jacks shall be placed, fastened, or equipped with devices to prevent slipping. On or about July 8, 2015- Job site at 214-11 16th Ave, Bayside, NY 11360 The employer permitted their employees to work on a ladder scaffold approximately 25 feet above the next lower level that was not equipped with devices to prevent slipping. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B16 |
Issuance Date |
2015-07-15 |
Abatement Due Date |
2015-07-27 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-08-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: On or about July 8, 2015- Job site at 214-11 16th Ave, Bayside, NY 11360 The employer permitted their employees to access a scaffold platform, approximately 25 feet above the ground, from a ladder with broken and damaged rungs. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $ 1,000.00 AS PER 29 CFR 1903.19. |
|
|