Search icon

JC LAND MANAGEMENT INC.

Company Details

Name: JC LAND MANAGEMENT INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 31 Oct 2007 (17 years ago)
Entity Number: 3587509
ZIP code: 11704
County: Suffolk
Place of Formation: New York
Address: 821 LITTLE EAST NECK RD, WEST BABYLON, NY, United States, 11704

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
JC LAND MANAGEMENT INC. DOS Process Agent 821 LITTLE EAST NECK RD, WEST BABYLON, NY, United States, 11704

Chief Executive Officer

Name Role Address
JOHN CENCI Chief Executive Officer 821 LITTLE EAST NECK RD, WEST BABYLON, NY, United States, 11704

History

Start date End date Type Value
2007-10-31 2012-08-14 Address 125 E NECK ROAD, HUNTINGTON, NY, 11743, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
221102003790 2022-11-02 BIENNIAL STATEMENT 2021-10-01
120814000349 2012-08-14 CERTIFICATE OF CHANGE 2012-08-14
071031000387 2007-10-31 CERTIFICATE OF INCORPORATION 2007-10-31

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347501850 0214700 2024-05-23 843 LAKE BLVD, LINDENHURST, NY, 11757
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-05-23
Emphasis N: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1750196
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2024-06-11
Abatement Due Date 2024-06-17
Current Penalty 1000.0
Initial Penalty 2489.0
Contest Date 2024-07-01
Final Order 2024-10-21
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) Worksite, 843 Lake Blvd, Lindenhurst, NY, 11757 - Two employees on site were installing roof rafters on a multi-story multi-residential structure. Two employees were standing on the same plank of a job made scaffold that was not fully planked approximately 10-feet above the lower level on the interior of the structure; on or about May 23, 2024. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2024-06-11
Abatement Due Date 2024-06-17
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2024-07-01
Final Order 2024-10-21
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) Worksite, 843 Lake Blvd, Lindenhurst, NY, 11757 - Two employees on site were installing roof rafters on a multi-story multi-residential structure. The employees were utilizing a job made scaffold and standing on a single plank approximately 10-feet above the lower level. The plank was not at least 18 inches wide; on or about May 23, 2024. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-06-11
Abatement Due Date 2024-06-17
Current Penalty 1000.0
Initial Penalty 3111.0
Contest Date 2024-07-01
Final Order 2024-10-21
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite, 843 Lake Blvd, Lindenhurst, NY, 11757 - Employees on site were installing roof rafters on a multi-story multi-residential dwelling. Employees were not utilizing a means of fall protection while working from the top plate of the exterior wall and were exposed to falling approximately 20-feet to the ground below; on or about May 23, 2024. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2024-06-11
Current Penalty 0.0
Initial Penalty 2489.0
Contest Date 2024-07-01
Final Order 2024-10-21
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Worksite, 843 Lake Blvd, Lindenhurst, NY, 11757 - Employees were using a Werner 8-foot a frame ladder to gain access to the 2nd floor exterior top plate of a 2-story multi-residential dwelling. The ladder was used in the closed position, leaning against the wall and employees were stepping on the top cap of the ladder to access the work area; on or about May 23, 2024. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19
Citation ID 01005A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-06-11
Current Penalty 1000.0
Initial Penalty 3111.0
Contest Date 2024-07-01
Final Order 2024-10-21
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Worksite, 843 Lake Blvd, Lindenhurst, NY, 11757 - Employees were using a Werner 8-foot a frame ladder to gain access to the 2nd floor exterior top plate of a 2-story multi-residential dwelling. The ladder did not extend 3-feet over the landing; on or about May 23, 2024. b) Worksite, 843 Lake Blvd, Lindenhurst, NY, 11757- employees were using a Werner 24-foot extension ladder to gain access the top of the 2nd level of a 2-story multi-residential dwelling under construction. The ladder did not extend 3-feet over the landing; on or about May 23, 20234 Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19
344658026 0214700 2020-02-27 766-768 DEER PARK AVENUE, NORTH BABYLON, NY, 11703
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2020-02-27
Case Closed 2020-07-09

Related Activity

Type Inspection
Activity Nr 1465801
Safety Yes
Type Inspection
Activity Nr 1465799
Safety Yes
Type Inspection
Activity Nr 1466935
Safety Yes
Type Inspection
Activity Nr 1466905
Safety Yes
Type Inspection
Activity Nr 1466627
Safety Yes
339437923 0214700 2013-10-22 72 LIGHTHOUSE RD, BABYLON, NY, 11702
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-10-22
Emphasis L: FALL, L: SANDY, P: FALL
Case Closed 2014-09-04

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260304 D
Issuance Date 2014-02-26
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2014-03-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(d): Portable, power-driven circular saw(s) were not equipped with a guard above and below the base plate or shoe: a) Worksite, East; Ground - Employee was engaged in cutting wood material for a residential home. The Makita, hand-held, circular saw used to cut material was used without the manufacturers safety cover/guard in place; on, or about 10/22/13. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-02-26
Abatement Due Date 2014-03-04
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2014-03-25
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite; Roof - Employees engaged in construction activities were observed working at the roof edge of a residential home, approximately 28 feet above the ground. Employees were not protected from falling, by guardrail systems, safety net systems or personal fall arrest systems; on, or about 10/22/13. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2014-02-26
Abatement Due Date 2014-03-24
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-03-25
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Worksite; Roof - Employees engaged in construction activities were observed working on the roof, and at the roof edge, of a residential building, approximately 28 feet above the ground. Employees did not receive training to recognize fall hazards; on, or about 10/22/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.