347501850
|
0214700
|
2024-05-23
|
843 LAKE BLVD, LINDENHURST, NY, 11757
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-05-23
|
Emphasis |
N: FALL, P: FALL
|
Related Activity
Type |
Inspection |
Activity Nr |
1750196 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2024-06-11 |
Abatement Due Date |
2024-06-17 |
Current Penalty |
1000.0 |
Initial Penalty |
2489.0 |
Contest Date |
2024-07-01 |
Final Order |
2024-10-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) Worksite, 843 Lake Blvd, Lindenhurst, NY, 11757 - Two employees on site were installing roof rafters on a multi-story multi-residential structure. Two employees were standing on the same plank of a job made scaffold that was not fully planked approximately 10-feet above the lower level on the interior of the structure; on or about May 23, 2024. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 B02 |
Issuance Date |
2024-06-11 |
Abatement Due Date |
2024-06-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2024-07-01 |
Final Order |
2024-10-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) Worksite, 843 Lake Blvd, Lindenhurst, NY, 11757 - Two employees on site were installing roof rafters on a multi-story multi-residential structure. The employees were utilizing a job made scaffold and standing on a single plank approximately 10-feet above the lower level. The plank was not at least 18 inches wide; on or about May 23, 2024. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-06-11 |
Abatement Due Date |
2024-06-17 |
Current Penalty |
1000.0 |
Initial Penalty |
3111.0 |
Contest Date |
2024-07-01 |
Final Order |
2024-10-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite, 843 Lake Blvd, Lindenhurst, NY, 11757 - Employees on site were installing roof rafters on a multi-story multi-residential dwelling. Employees were not utilizing a means of fall protection while working from the top plate of the exterior wall and were exposed to falling approximately 20-feet to the ground below; on or about May 23, 2024. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2024-06-11 |
Current Penalty |
0.0 |
Initial Penalty |
2489.0 |
Contest Date |
2024-07-01 |
Final Order |
2024-10-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Worksite, 843 Lake Blvd, Lindenhurst, NY, 11757 - Employees were using a Werner 8-foot a frame ladder to gain access to the 2nd floor exterior top plate of a 2-story multi-residential dwelling. The ladder was used in the closed position, leaning against the wall and employees were stepping on the top cap of the ladder to access the work area; on or about May 23, 2024. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19 |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2024-06-11 |
Current Penalty |
1000.0 |
Initial Penalty |
3111.0 |
Contest Date |
2024-07-01 |
Final Order |
2024-10-21 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Worksite, 843 Lake Blvd, Lindenhurst, NY, 11757 - Employees were using a Werner 8-foot a frame ladder to gain access to the 2nd floor exterior top plate of a 2-story multi-residential dwelling. The ladder did not extend 3-feet over the landing; on or about May 23, 2024. b) Worksite, 843 Lake Blvd, Lindenhurst, NY, 11757- employees were using a Werner 24-foot extension ladder to gain access the top of the 2nd level of a 2-story multi-residential dwelling under construction. The ladder did not extend 3-feet over the landing; on or about May 23, 20234 Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19 |
|
|
344658026
|
0214700
|
2020-02-27
|
766-768 DEER PARK AVENUE, NORTH BABYLON, NY, 11703
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-02-27
|
Case Closed |
2020-07-09
|
Related Activity
Type |
Inspection |
Activity Nr |
1465801 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1465799 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1466935 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1466905 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1466627 |
Safety |
Yes |
|
|
339437923
|
0214700
|
2013-10-22
|
72 LIGHTHOUSE RD, BABYLON, NY, 11702
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-10-22
|
Emphasis |
L: FALL, L: SANDY, P: FALL
|
Case Closed |
2014-09-04
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260304 D |
Issuance Date |
2014-02-26 |
Current Penalty |
960.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-03-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(d): Portable, power-driven circular saw(s) were not equipped with a guard above and below the base plate or shoe: a) Worksite, East; Ground - Employee was engaged in cutting wood material for a residential home. The Makita, hand-held, circular saw used to cut material was used without the manufacturers safety cover/guard in place; on, or about 10/22/13. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-02-26 |
Abatement Due Date |
2014-03-04 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-03-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite; Roof - Employees engaged in construction activities were observed working at the roof edge of a residential home, approximately 28 feet above the ground. Employees were not protected from falling, by guardrail systems, safety net systems or personal fall arrest systems; on, or about 10/22/13. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2014-02-26 |
Abatement Due Date |
2014-03-24 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-03-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Worksite; Roof - Employees engaged in construction activities were observed working on the roof, and at the roof edge, of a residential building, approximately 28 feet above the ground. Employees did not receive training to recognize fall hazards; on, or about 10/22/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
|