Search icon

FISHER BUILDERS, INC.

Company Details

Name: FISHER BUILDERS, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 29 Nov 2007 (17 years ago)
Date of dissolution: 27 Jun 2013
Entity Number: 3598872
ZIP code: 12561
County: Ulster
Place of Formation: New York
Address: 96 MARTIN SWEEDISH ROAD, NEW PALTZ, NY, United States, 12561

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 96 MARTIN SWEEDISH ROAD, NEW PALTZ, NY, United States, 12561

Chief Executive Officer

Name Role Address
SUZANNE FISHER Chief Executive Officer 96 MARTIN SWEEDISH ROAD, NEW PALTZ, NY, United States, 12561

Filings

Filing Number Date Filed Type Effective Date
130627000341 2013-06-27 CERTIFICATE OF DISSOLUTION 2013-06-27
111216002468 2011-12-16 BIENNIAL STATEMENT 2011-11-01
091203002667 2009-12-03 BIENNIAL STATEMENT 2009-11-01
071129000382 2007-11-29 CERTIFICATE OF INCORPORATION 2007-11-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339498917 0213100 2013-11-22 30 AIRWAY DRIVE, LAGRANGEVILLE, NY, 12540
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-11-22
Emphasis L: FALL
Case Closed 2016-05-09

Related Activity

Type Complaint
Activity Nr 863097
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260452 K02
Issuance Date 2014-01-31
Current Penalty 680.0
Initial Penalty 1360.0
Final Order 2014-02-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(k)(2): Ladders used to support the ladderjack scaffolding did not meet the requirements of Sub-part X: a) On or about November 22, 2013 and at times prior thereto at the jobsite; ladders used to support the ladderjack scaffold didn't meet Sub-part X requirements in that employees were using 2 sections of an extension ladder seperately, both sections were used at an angle greater than a quarter of the ladders length, and one of the ladder sections was placed on a slippery surface in the trash container.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260452 K04
Issuance Date 2014-01-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(k)(4): 29 CFR 1926.452(k)(4) Ladders used to support ladder jacks were not placed, fastened, or equipped with devices to prevent slipping: a) On or about November 22, 2013 and at times prior thereto at the jobsite; one of the ladders used to support the ladderjack scaffold had been placed inside a metal trash container that had asphalt and slate shingles in it.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260452 K05
Issuance Date 2014-01-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(k)(5): Scaffold platforms were bridged on to another: a) On or about November 22, 2013 and at times prior thereto at the jobsite; a damaged wooden scaffold plank was bridged onto the aluminum scaffold platform.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2014-01-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about November 22, 2013 and at times prior thereto at the jobsite; an extension ladder was broken into its two sections and used as two seperate ladders to support a ladderjack scaffold.
Citation ID 01001E
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2014-01-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-26
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a) On or about November 22, 2013 and at times prior thereto at the worksite; the ladder used to access the roof had an angle greater than one quarter the height of the ladder. b) On or about November 22, 2013 and at times prior thereto at the worksite; the ladders used to support the ladderjack scaffold had an angle greater than one quarter the height of the ladders.
Citation ID 01001F
Citaton Type Serious
Standard Cited 19261053 B07
Issuance Date 2014-01-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(7): Ladder(s) that were unsecured or not provided with slip-resistant feet were used on slippery surfaces: a) On or about November 22, 2013 and at times prior thereto at the worksite; one of the ladderjack scaffold ladders was placed in a metal trash container full of asphalt and slate shingles.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2014-01-31
Current Penalty 1020.0
Initial Penalty 2040.0
Final Order 2014-02-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about November 22, 2013 and at times prior thereto at the jobsite; employees were replacing an 8 on 12 sloped shingle roof with a ground to eave height of 10' without the use of any fall protection.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2014-01-31
Abatement Due Date 2014-02-07
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2014-02-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about November 22, 2013 and at times prior thereto at the job site; employees were performing roofing work without having any training to recognize fall hazards and procedures to protect themselves.

Date of last update: 28 Mar 2025

Sources: New York Secretary of State