Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-04-09
|
Case Closed |
2016-02-22
|
Related Activity
Type |
Inspection |
Activity Nr |
1045701 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19101001 J02 |
Issuance Date |
2015-04-23 |
Abatement Due Date |
2015-05-28 |
Current Penalty |
0.0 |
Initial Penalty |
2000.0 |
Contest Date |
2015-05-15 |
Final Order |
2015-09-10 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1001(j)(2): The Building and facility owners did not determine the presence, location and quantity of ACM and PACM. The employer and building and faculty owners did not exercise due diligence in complying with requirements to inform employers and employees about presence and location of ACM and PACM. a) 1 Boys Club Pl., Rochester, NY - On or about 03/30/15 and ongoing, employer did not determine the presence, location and quantity of asbestos containing material (ACM), and or PACM (presumed asbestos containing material). Thermal System Insulation (TSI) which contained 10% and 15% of Amosite and Chrysotile asbestos. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19101001 J05 I |
Issuance Date |
2015-04-23 |
Abatement Due Date |
2015-05-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2015-05-15 |
Final Order |
2015-09-10 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1001(j)(5)(i): The employer did not affix signs or labels so that employees would be notified of what materials contain ACM and/or PACM to materials that were previously identified to be ACM and/or PACM a) 1 Boys Club Pl., Rochester, NY - On or about 03/30/2015, labels were not affixed to any ACM/PCAM in the building including Thermal System Insulation (TSI) which contained 10% and 15% of Amosite and Chrysotile asbestos. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19101001 J07 |
Issuance Date |
2015-04-23 |
Abatement Due Date |
2015-08-31 |
Current Penalty |
500.0 |
Initial Penalty |
2000.0 |
Contest Date |
2015-05-15 |
Final Order |
2015-09-10 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1001(j)(7): The employer did not provide, at no cost to employees who perform housekeeping operations in an area which contains presumed asbestos-containing material (PACM) and/or other asbestos-containing material (ACM), an asbestos awareness training course: a) 1 Boys Club Pl., Rochester, NY - On or about 03/30/2015, the employer did not institute a training program to employees who perform housekeeping in areas where TSI containing 10% and 15% asbestos are located. ABATEMENT CERTIFICATION REQUIRED |
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2013-07-25
|
Case Closed |
2014-04-18
|
Related Activity
Type |
Complaint |
Activity Nr |
821926 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19261101 D01 |
Issuance Date |
2013-10-23 |
Current Penalty |
500.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-11-15 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1101(d)(1): On a multi-employer worksite, the employer performing work requiring the establishment of a regulated area did not inform other employers on site of the nature of the employer's work with asbestos, of the existence of and requirements pertaining to regulated areas, and the measures taken to ensure that employees of such other employers are not exposed to asbestos: a) East Avenue Commons-111 East Avenue, Rochester, NY 14604 - On or about 06/21/13-7/25/13, the employer performing Class II asbestos work requiring the establishment of a regulated area, working on a multi-employer worksite did not inform other employers, including but not limited to BCD Home Improvements of the nature of the employer's work with asbestos and/or PACM, of the existence of and requirements pertaining to regulated areas, and the measures taken to ensure that employees of such other employers are not exposed to asbestos. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261101 E01 |
Issuance Date |
2013-10-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-11-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1101(e)(1): All Class I, II, and III asbestos work was not conducted within regulated areas: a) East Avenue Commons, 111 East Avenue, Rochester, NY 14604 - On or about 06/21/13-7/25/13, a regulated area was not established for employees performing Class II asbestos work. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261101 F01 I |
Issuance Date |
2013-10-23 |
Current Penalty |
500.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-11-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1101(f)(1)(i): Each employer who has a workplace or work operation where exposure monitoring is required under this section shall perform monitoring to determine accurately the airborne concentrations of asbestos to which employees may be exposed. a) East Avenue Commons, 111 East Avenue, Rochester, NY 14604 - On or about 06/21/13-7/25/13, the employer did not perform exposure monitoring to determine the airborne concentrations of asbestos to which employees performing Class II asbestos work were exposed. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261101 H02 I |
Issuance Date |
2013-10-23 |
Current Penalty |
0.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-11-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1101(h)(2)(i): The employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) (except (d)(1)(iii), and (f) through (m): a) East Avenue Commons, 111 East Avenue, Rochester, NY 14604 - On or about 06/21/13-7/25/13, where employees were performing Class II asbestos work in room #115, the employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) (except (d)(1)(iii), and (f) through (m). NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261101 K09 I |
Issuance Date |
2013-10-23 |
Current Penalty |
0.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-11-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1101(k)(9)(i): The employer shall train each employee who is likely to be exposed in excess of a PEL, and each employee who performs Class I through IV asbestos operations, in accordance with the requirements of this section. Such training shall be conducted at no cost to the employee. The employer shall institute a training program and ensure employee participation in the program. a) East Avenue Commons, 111 East Avenue, Rochester, NY 14604 - On or about 06/21/13-7/25/13, employees performing Class II activities in the East Avenue Commons area and had not received appropriate training. NO ABATEMENT CERTIFICATION REQUIRED |
|
|