Search icon

MC&O BUILDERS INC.

Company Details

Name: MC&O BUILDERS INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 15 Jan 2008 (17 years ago)
Entity Number: 3617726
ZIP code: 11378
County: Queens
Place of Formation: New York
Address: PO BOX 780227, MASPETH, NY, United States, 11378
Principal Address: 1925 FLUSHING AVENUE, RIDGEWOOD, NY, United States, 11385

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
OWEN G O'REILLY Chief Executive Officer PO BOX 780227, MASPETH, NY, United States, 11378

DOS Process Agent

Name Role Address
OWEN G O'REILLY DOS Process Agent PO BOX 780227, MASPETH, NY, United States, 11378

History

Start date End date Type Value
2021-09-10 2022-08-03 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2008-01-15 2021-09-10 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2008-01-15 2012-02-14 Address OWEN O'REILLY, 1925 FLUSHING AVENUE, RIDGEWOOD, NY, 11385, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
120214002031 2012-02-14 BIENNIAL STATEMENT 2012-01-01
080115000361 2008-01-15 CERTIFICATE OF INCORPORATION 2008-01-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340769017 0215000 2015-07-08 149 KENT AVENUE, BROOKLYN, NY, 11249
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2015-07-08
Emphasis L: FALL
Case Closed 2017-03-03

Related Activity

Type Accident
Activity Nr 999210
Health Yes
Type Inspection
Activity Nr 1075960
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2015-12-30
Abatement Due Date 2016-01-12
Current Penalty 2750.0
Initial Penalty 5390.0
Contest Date 2016-01-27
Final Order 2016-06-03
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: 149 Kent Avenue, Brooklyn, NY. a) Employees worked from tubular welded frame scaffold and were not protected from falling 24 feet to ground by the use of fall protection systems. On or about 07/08/2015.