Filing Number Date Filed Type Effective Date
DP-2132231 2012-04-25 DISSOLUTION BY PROCLAMATION 2012-04-25
080214000042 2008-02-14 CERTIFICATE OF INCORPORATION 2008-02-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
332425479 0215600 2012-02-08 184-44 MIDLAND PARKWAY, JAMAICA, NY, 11432
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-02-08
Emphasis L: FALL
Case Closed 2012-12-20

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2012-05-07
Current Penalty 1250.0
Initial Penalty 2550.0
Contest Date 2012-05-22
Final Order 2012-10-26
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) On or about February 8, 2012Job site at 184-44 Midland Parkway Jamaica Estates, NY 11432 Tubular welded frame scaffold was missing a 9 inch wide plank. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2012-05-07
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2012-05-22
Final Order 2012-12-20
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a) On or about February 8, 2012Job site at 184-44 Midland Parkway Jamaica Estates, NY 11432 Employee was climbing tubular welded frame scaffold to a height of 10 feet - 4 inches. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2012-05-07
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2012-05-22
Final Order 2012-12-20
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) On or about February 8, 2012Job site at 184-44 Midland Parkway Jamaica Estates, NY 11432 Employee was on tubuler welded frame scaffold to a height of 10 feet - 4 inces without fall protection . WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2012-05-07
Abatement Due Date 2012-06-19
Current Penalty 1250.0
Initial Penalty 3000.0
Contest Date 2012-05-22
Final Order 2012-10-26
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: a) On or about February 8, 2012Job site at 184-44 Midland Parkway Jamaica Estates, NY 11432 Employee could not identify scaffold hazards due to lack of training. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.