Name: | ROGERSTAN CONSTRUCTION INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Inactive |
Date of registration: | 18 Mar 2008 (17 years ago) |
Date of dissolution: | 29 Jun 2016 |
Entity Number: | 3646024 |
ZIP code: | 11224 |
County: | Kings |
Place of Formation: | New York |
Address: | 2929 WEST 31ST STREET, BROOKLYN, NY, United States, 11224 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 2929 WEST 31ST STREET, BROOKLYN, NY, United States, 11224 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
DP-2156504 | 2016-06-29 | DISSOLUTION BY PROCLAMATION | 2016-06-29 |
080318000601 | 2008-03-18 | CERTIFICATE OF INCORPORATION | 2008-03-18 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
332802636 | 0215600 | 2012-03-09 | 53-05 65TH PLACE, MASPETH, NY, 11378 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 216829 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19260405 E01 |
Issuance Date | 2012-07-25 |
Abatement Due Date | 2012-07-26 |
Current Penalty | 0.0 |
Initial Penalty | 3000.0 |
Final Order | 2012-08-16 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.405(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures: a) On or about March 9, 2012-Job site at 53-05 65 th Place Maspeth NY 11378 Employees exposed to electrical hazards from water getting into electrical box. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B04 II |
Issuance Date | 2012-07-25 |
Current Penalty | 1250.0 |
Initial Penalty | 2550.0 |
Final Order | 2012-08-16 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers: a) On or about March 9, 2012-Job site at 53-05 65 th Place Maspeth, NY 11378 Employees were exposed to falls of 10 to the next lower level from the roof. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2012-07-25 |
Current Penalty | 1250.0 |
Initial Penalty | 2550.0 |
Final Order | 2012-08-16 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about March 9, 2012-Job site at 53-05 65 th Place Maspeth NY 11378 Employees exposed to fall from ladder not 3-feet above the surface being accessed. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
Date of last update: 28 Mar 2025
Sources: New York Secretary of State