Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-04-16
|
Case Closed |
2021-09-09
|
Related Activity
Type |
Complaint |
Activity Nr |
1755973 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2021-08-24 |
Abatement Due Date |
2021-08-30 |
Current Penalty |
4849.65 |
Initial Penalty |
7461.0 |
Final Order |
2021-09-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Pallet Area of Machine 2 - On or about April 14, 2021 an employee was exposed to caught-in hazards due to performing cleaning operations when going into the machine with a Shop Vac to clean out dirt and debris without utilizing the lockout/tagout procedure. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2021-08-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-09-03 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Light Curtain Area on Machine 1 - On or prior to April 16, 2021, employees operating Machine 1 (Make: Canconex, Model: Sort Pro Series 2 Model # SP017, Serial Number: 1620) were exposed to caught-in hazards due there being no guarding installed next to the light curtain area. b) Light Curtain Area on Machine 2 - On or prior to April 16, 2021, employees operating Machine 2 (Make: Canconex, Model: Sort Pro Series 2 Model # SP017, Serial Number: 2751) were exposed to caught-in hazards due there being no guarding installed next to the light curtain area. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100219 H01 |
Issuance Date |
2021-08-24 |
Current Penalty |
5819.45 |
Initial Penalty |
8953.0 |
Final Order |
2021-09-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(h)(1):Projecting key(s), setscrew(s), or other projections in revolving part(s) were not removed, made flush, or guarded by metal cover(s): a) Machine 2 in area where operator primarily stands to operate machine - On or about April 16, 2021, Machine 2 (Make: Canconex, Model: Sort Pro Series 2 Model # SP017, Serial Number: 2751) had a rotating bearing with projecting setscrews or other projections that were not adequately guarded exposing the operator employee to caught-in hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 B01 II |
Issuance Date |
2021-08-24 |
Abatement Due Date |
2021-10-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-09-03 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Facility - On or about April 16, 2021, there were missing knockout plugs on the control panels for Machine 1 and Machine 2, as well as missing knockout plugs on the electrical panels and boxes on the wall near Machine 1 and 2. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2021-08-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-09-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Machine 2 - On or prior to April 16, 2021, an extension cord was being used as permanent wiring to power a light for Machine 2 (Make: Canconex, Model: Sort Pro Series 2 Model # SP017, Serial Number: 2751). |
|
|