Name: | COAST TRANSPORTATION AND RECYCLING, LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 16 Apr 2008 (17 years ago) |
Entity Number: | 3659097 |
ZIP code: | 13090 |
County: | Onondaga |
Place of Formation: | New York |
Address: | 121 GREEN ACRES DRIVE, LIVERPOOL, NY, United States, 13090 |
Name | Role | Address |
---|---|---|
C/O ABITBOL & CHERRY, LLP | DOS Process Agent | 121 GREEN ACRES DRIVE, LIVERPOOL, NY, United States, 13090 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
100415002806 | 2010-04-15 | BIENNIAL STATEMENT | 2010-04-01 |
080416000287 | 2008-04-16 | ARTICLES OF ORGANIZATION | 2008-04-16 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344187562 | 0215800 | 2019-07-26 | 15 DIPPOLD AVENUE, SYRACUSE, NY, 13208 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1481551 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 5A0001 |
Issuance Date | 2019-11-04 |
Abatement Due Date | 2019-11-15 |
Current Penalty | 2842.0 |
Initial Penalty | 2842.0 |
Final Order | 2019-11-29 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck by hazard: a) On or about 7/26/2019, Behind the building: Employees were working underneath a load suspended by a Komatsu WA380 loader. This operation could result in employees receiving crushing injuries due to being struck by a load. Abatement certification is required for this item. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100253 E03 II C 2 |
Issuance Date | 2019-11-04 |
Abatement Due Date | 2019-11-15 |
Current Penalty | 1705.0 |
Initial Penalty | 1705.0 |
Final Order | 2019-11-29 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.253(e)(3)(ii)(C)(2): Back flow protection was not provided by an approved device that would prevent oxygen from flowing into the fuel gas system or fuel from flowing into the oxygen system: a) On or about 7/26/2019, Behind the building: Employees were utilizing an oxy/ acet cutting torch which was not provided with any back flow prevention. Abatement certification is required for this item. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19100303 B01 |
Issuance Date | 2019-11-04 |
Abatement Due Date | 2019-11-15 |
Current Penalty | 2273.0 |
Initial Penalty | 2273.0 |
Final Order | 2019-11-29 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) On or about 7/26/2019, Behind the building: Employees were utilizing extension cords with damaged insulation. Abatement certification is required for this item. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19100304 G05 |
Issuance Date | 2019-11-04 |
Abatement Due Date | 2019-11-15 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-11-29 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) On or about 7/26/2019, Behind the building: Employees were utilizing extension cords to power a cut off saw. The cords were not provided with a continuous path to ground. Abatement certification is required for this item. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19100305 E01 |
Issuance Date | 2019-11-04 |
Abatement Due Date | 2019-11-15 |
Current Penalty | 2273.0 |
Initial Penalty | 2273.0 |
Final Order | 2019-11-29 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Inspection NR | 1463593 |
FTA Issuance Date | 2020-05-15 |
FTA Current Penalty | 69399.0 |
FTA Final Order Date | 2020-06-10 |
Citation text line | 29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures: a) On or about 7/26/2019, Behind the building: Employees were utilizing an electrical outlet which was not rated for use in a wet location. Abatement certification is required for this item. |
Date of last update: 28 Mar 2025
Sources: New York Secretary of State