Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-06-30
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2015-07-02
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 I |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-15 |
Current Penalty |
0.0 |
Initial Penalty |
2400.0 |
Final Order |
2014-08-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) At the jobsite, on or about 6/30/14: Employees were using a compressor to power pneumatic tools and power tools without GFI protection. Abatement certification must be submitted for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260405 G02 IV |
Issuance Date |
2014-07-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-08-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:( a) At the jobsite, on or about 6/30/14: Employees were using a compressor to power pneumatic tools and power tools without GFI protection and where an extension cord was used that was pulling free from the plug end. |
|
Citation ID |
01001C |
Citaton Type |
Other |
Standard Cited |
19260405 B03 I |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-08-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(b)(3)(i): Boxes were not provided with a complete enclosure for the contained conductors or cables. a) At the jobsite, on or about 6/30/14: Employees were using a compressor to power pneumatic tools and power tools without GFI protection and where an extension cord was used that was pulling free from the plug end and where that cord was plugged into an outlet in close proximity to live wires in an uncovered junction box. Abatement certification must be submitted for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-15 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-08-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) At the jobsite, on a scaffold approximately 16 feet from ground, on or about 6/30/14: An employee was installing shingles to a brow of a window without fall protection. Abatement documentation must be submitted for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 I |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-08-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: a) At the jobsite, on a scaffold approximately 16 feet from ground, on or about 6/30/14: An employee was installing shingles to a brow of a window without fall protection and where one end of the working platform was supported by a roof section that was lower than the opposite support and sloped backward from the work position. Abatement certification must be submitted for this item. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19260451 F07 |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-08-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) At the jobsite, on a scaffold approximately 16 feet from ground, on or about 6/30/14: An employee was installing shingles to a brow of a window without fall protection and where one end of the working platform was supported by a roof section that was lower than the opposite support and sloped backward from the work position. Abatement documentation must be submitted for this item. |
|
|