Name: | G & S CONSTRUCTION VENTURES CORP. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 28 Apr 2008 (17 years ago) |
Entity Number: | 3663948 |
ZIP code: | 11228 |
County: | Kings |
Place of Formation: | New York |
Address: | 160 BAY 8TH ST, BROOKLYN, NY, United States, 11228 |
Contact Details
Phone +1 718-761-1734
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
G & S CONSTRUCTION VENTURES CORP. | DOS Process Agent | 160 BAY 8TH ST, BROOKLYN, NY, United States, 11228 |
Name | Role | Address |
---|---|---|
GIANCARLO CAPILLO | Chief Executive Officer | 160 BAY 8TH ST, BROOKLYN, NY, United States, 11228 |
Number | Status | Type | Date | End date |
---|---|---|---|---|
1291572-DCA | Active | Business | 2008-07-08 | 2025-02-28 |
Start date | End date | Type | Value |
---|---|---|---|
2008-04-28 | 2013-10-11 | Address | 1204 AVENUE U, STE. 1109, BROOKLYN, NY, 11229, USA (Type of address: Service of Process) |
2008-04-28 | 2024-08-07 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
131011006843 | 2013-10-11 | BIENNIAL STATEMENT | 2012-04-01 |
080428000514 | 2008-04-28 | CERTIFICATE OF INCORPORATION | 2008-04-28 |
Date | Inspection Object | Address | Grade | Type | Institution | Desctiption |
---|---|---|---|---|---|---|
2014-05-24 | No data | Bronx, BROOKLYN, NY, 11228 | No Violation Issued | Inspectorate of the Department of Consumer and Workers' Rights Protection | Department of Consumer and Worker Protection | No data |
Fee Sequence Id | Fee type | Status | Date | Amount | Description |
---|---|---|---|---|---|
3592574 | TRUSTFUNDHIC | INVOICED | 2023-02-02 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
3592575 | RENEWAL | INVOICED | 2023-02-02 | 100 | Home Improvement Contractor License Renewal Fee |
3297933 | RENEWAL | INVOICED | 2021-02-19 | 100 | Home Improvement Contractor License Renewal Fee |
3297932 | TRUSTFUNDHIC | INVOICED | 2021-02-19 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2969519 | RENEWAL | INVOICED | 2019-01-28 | 100 | Home Improvement Contractor License Renewal Fee |
2940623 | DCA-SUS | CREDITED | 2018-12-07 | 75 | Suspense Account |
2940622 | PROCESSING | INVOICED | 2018-12-07 | 25 | License Processing Fee |
2915653 | RENEWAL | CREDITED | 2018-10-24 | 100 | Home Improvement Contractor License Renewal Fee |
2915652 | TRUSTFUNDHIC | INVOICED | 2018-10-24 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2734634 | LICENSEDOC10 | INVOICED | 2018-01-29 | 10 | License Document Replacement |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339492456 | 0215000 | 2013-11-19 | 167 & 169 DEAN STREET, BROOKLYN, NY, 11232 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 862786 |
Safety | Yes |
Violation Items
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2014-01-17 |
Abatement Due Date | 2014-02-06 |
Current Penalty | 1625.0 |
Initial Penalty | 2000.0 |
Final Order | 2014-03-03 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Jobsite: The employer did not provide training to employees who erected and worked from a ladder jack scaffold. Employees could not recognize hazards associated with the scaffold, and were exposed to hazards, including but not limited to: falling more than 10 feet from the scaffold platform to ground. On or about 11/19/13. NOTE: IN ADDITION TO CERTIFICATION OF ABATEMENT, THE EMPLOYER IS REQUIRED TO SUBMIT DOCUMENTATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19261060 A |
Issuance Date | 2014-01-17 |
Abatement Due Date | 2014-02-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-03-03 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways. a) Jobsite: The employer did not provide training to an employee who was exposed to hazards related to stepladders, including but not limited to: using the top or top step of a stepladder as a step. On or about 11/19/13. NOTE: IN ADDITION TO CERTIFICATION OF ABATEMENT, THE EMPLOYER IS REQUIRED TO SUBMIT DOCUMENTATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2014-01-17 |
Current Penalty | 1625.0 |
Initial Penalty | 2000.0 |
Final Order | 2014-03-03 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or top step of a stepladder shall not be used as a step. a) In front of house: An employee used top step of an A-frame stepladder to climb and stood on the top of the stepladder for elevation to work. On or about 11/19/13. Note: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification of abatement for this violation as normally required by 29 CFR 1903.19. |
Citation ID | 01006A |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2014-01-17 |
Current Penalty | 2000.0 |
Initial Penalty | 2800.0 |
Final Order | 2014-03-03 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. a) In front of house: Three employees were working on a platform of a ladder jack scaffold and were not protected from falling to ground by the use of fall protection systems. Employees were exposed to falling approximately 14 feet. On or about 11/19/13. Note: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification of abatement for this violation as normally required by 29 CFR 1903.19. |
Citation ID | 01006B |
Citaton Type | Serious |
Standard Cited | 19260452 K03 |
Issuance Date | 2014-01-17 |
Current Penalty | 0.0 |
Initial Penalty | 2800.0 |
Final Order | 2014-03-03 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.452(k)(3): The ladder jack shall be so designed and constructed that it will bear on the side rails and ladder rungs or on the ladder rungs alone. If bearing on rungs only, the bearing area shall include a length of at least 10 inches (25.4 cm) on each rung. a) In front of house: Three employees were working on a platform of a ladder jack scaffold and the ladder jack did not bear on the side rails of both ladders being used to suport the platform. One extension ladder was erected with the platform support on the interior portion of the ladder bearing on the wall of the buidling. Employees were exposed to falling approximately 14 feet. On or about 11/19/13. Note: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification of abatement for this violation as normally required by 29 CFR 1903.19. |
Date of last update: 28 Mar 2025
Sources: New York Secretary of State