Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-05-22
|
Emphasis |
L: FALL, L: LOCALTARG, P: FALL
|
Case Closed |
2023-01-11
|
Related Activity
Type |
Inspection |
Activity Nr |
1236464 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1236522 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260403 B02 |
Issuance Date |
2017-08-04 |
Current Penalty |
3803.0 |
Initial Penalty |
3803.0 |
Final Order |
2017-09-07 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a- Seventh Floor - 1460 Fulton Street, Brooklyn NY: On or about 5/22/17 site workers were exposed to electrocution hazards when using a metal junction box that was not mounted in accordance with in the listing, labeling and/or certification. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260403 I02 I |
Issuance Date |
2017-08-04 |
Current Penalty |
3803.0 |
Initial Penalty |
3803.0 |
Final Order |
2017-09-07 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a- Seventh Floor - 1460 Fulton Street, Brooklyn NY: On or about 5/22/17 site workers were exposed to electrocution hazards when using an unmounted, uncovered, junction box containing live receptacles. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260405 G02 III |
Issuance Date |
2017-08-04 |
Current Penalty |
3803.0 |
Initial Penalty |
3803.0 |
Final Order |
2017-09-07 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: a - Third Floor - 1460 Fulton Street, Brooklyn NY: On or about 05/22/17 an electric portable circular saw was powered with a flexible extension cord that contained a splice and was not continuous in length. b - Seventh - 1460 Fulton Street, Brooklyn NY: On or about 05/22/17 an electric space heater was powered with a white flexible cord that contained a splice and was not continuous in length. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260416 E01 |
Issuance Date |
2017-08-04 |
Current Penalty |
3803.0 |
Initial Penalty |
3803.0 |
Final Order |
2017-09-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a - Third Floor - 1460 Fulton Street, Brooklyn NY: On or about 05/22/17 an electric portable circular saw was powered with a flexible extension cord whose outer covering was visibly damaged and missing in some areas. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260501 B14 |
Issuance Date |
2017-08-04 |
Abatement Due Date |
2017-08-10 |
Current Penalty |
3803.0 |
Initial Penalty |
3803.0 |
Final Order |
2017-09-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. a - Third Floor - 1460 Fulton Street, Brooklyn NY: On or about 05/22/17 a company employee was exposed to fall hazards when working at an unprotected wall opening without the use of any fall protection. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19. |
|
|