Inspection Type |
Fat/Cat
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-03-22
|
Case Closed |
2022-03-09
|
Related Activity
Type |
Accident |
Activity Nr |
1743444 |
|
Type |
Inspection |
Activity Nr |
1550668 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100146 C01 |
Issuance Date |
2021-09-03 |
Abatement Due Date |
2021-09-23 |
Current Penalty |
1920.0 |
Initial Penalty |
2926.0 |
Contest Date |
2021-09-24 |
Final Order |
2022-03-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(1):The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces. Location: a) Inside elevator motor room of passenger elevator, ID: 3P871: On or about March 5, 2021, the employer did not request the elevator maintenance company responsible for servicing and maintaining passenger elevator, ID: 3P871 to evaluate if the elevator pit room was a permit-required confined space. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100146 C02 |
Issuance Date |
2021-09-03 |
Abatement Due Date |
2021-09-23 |
Current Penalty |
0.0 |
Initial Penalty |
2926.0 |
Contest Date |
2021-09-24 |
Final Order |
2022-03-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(2):The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces. Location: a) Inside elevator motor room of passenger elevator, ID: 3P871: On or about March 5, 2021, an employee entered an elevator motor room to retrieve a dropped phone. The room was a permit-required confined space, and the employer did not post danger signs or other equally effective means to inform employees of the existence and location of the permit space, and the hazards presented by the elevator equipment. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100146 C03 |
Issuance Date |
2021-09-03 |
Abatement Due Date |
2021-09-23 |
Current Penalty |
3840.5 |
Initial Penalty |
2926.0 |
Contest Date |
2021-09-24 |
Final Order |
2022-03-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(3): When the employer decided its employees would not enter permit spaces, the employer did not take effective measures to prevent its employees from entering the permit spaces. Location: a) Inside elevator pit of passenger elevator, ID: 3P871: On or about March 5, 2021, an employee entered an elevator motor room to retrieve a dropped phone which was located in the elevator pit. The elevator pit was a permit-required confined space, and the employer's in-place measures to prevent its employees from entering the elevator pit did not prevent him from doing so. |
|
Citation ID |
01004A |
Citaton Type |
Other |
Standard Cited |
19100146 C08 I |
Issuance Date |
2021-09-03 |
Abatement Due Date |
2021-09-23 |
Current Penalty |
1921.0 |
Initial Penalty |
2926.0 |
Contest Date |
2021-09-24 |
Final Order |
2022-03-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(8)(i):When an employer arranged to have employees of another employer (contractor) perform work that involved permit space entry, the host employer did not inform the contractor that the workplace contained permit spaces and that permit space entry is allowed only through compliance with a permit space program meeting the requirements of this section. Location: a) Inside elevator pit of passenger elevator, ID: 3P871: On or about March 8, 2021, the host employer arranged to have employees of an elevator maintenance contractor to perform monthly maintenance that involved permit space entry. The host employer did not inform the contractor that the workplace contained a permit space and that entry into the permit space is allowed only through compliance with a permit space program. |
|
Citation ID |
01004B |
Citaton Type |
Other |
Standard Cited |
19100146 C08 II |
Issuance Date |
2021-09-03 |
Abatement Due Date |
2021-09-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2021-09-24 |
Final Order |
2022-03-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(8)(ii): When an employer arranged to have employees of another employer (contractor) perform work that involved permit space entry, the host employer did not apprise the contractor of the elements, including the hazards identified and the host employer's experience with the space, that make the space in question a permit space. Location: a) Inside elevator motor room of passenger elevator, ID: 3P871: On or about March 8, 2021, the host employer arranged to have employees of an elevator maintenance contractor to perform monthly maintenance that involved permit space entry. The host employer did not apprise the contractor of the elements that make the space in question a permit space. |
|
Citation ID |
01004C |
Citaton Type |
Serious |
Standard Cited |
19100146 C08 III |
Issuance Date |
2021-09-03 |
Abatement Due Date |
2021-09-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2021-09-24 |
Final Order |
2022-03-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(8)(iii): When an employer arranged to have employees of another employer (contractor) perform work that involved permit space entry, the host employer did not apprise the contractor of any precautions or procedures that the host employer has implemented for the protection of employees in or near permit spaces where contractor personnel will be working. Location: a) Inside elevator motor room of passenger elevator, ID: 3P871: On or about March 8, 2021, the host employer arranged to have employees of an elevator maintenance contractor to perform monthly maintenance that involved permit space entry. The host employer did not apprise the contractor of any precautions or procedures that they have implemented for the protection of employees in or near the permit space where the contractor employees would be working. |
|
|