Name: | TOTAL METAL RESOURCE, INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Inactive |
Date of registration: | 21 Jul 2008 (17 years ago) |
Date of dissolution: | 04 Apr 2023 |
Entity Number: | 3698597 |
ZIP code: | 11222 |
County: | Kings |
Place of Formation: | New York |
Address: | 51 55 NASSAU AVENUE, SUITE 1C, BROOKLYN, NY, United States, 11222 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
SCOTT S. BEHR | DOS Process Agent | 51 55 NASSAU AVENUE, SUITE 1C, BROOKLYN, NY, United States, 11222 |
Start date | End date | Type | Value |
---|---|---|---|
2008-07-21 | 2023-04-04 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2008-07-21 | 2023-07-16 | Address | 51 55 NASSAU AVENUE, SUITE 1C, BROOKLYN, NY, 11222, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
230716000062 | 2023-04-04 | CERTIFICATE OF DISSOLUTION-CANCELLATION | 2023-04-04 |
080721000410 | 2008-07-21 | CERTIFICATE OF INCORPORATION | 2008-07-21 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342099272 | 0215000 | 2017-02-13 | 175 BOGART STREET, BROOKLYN, NY, 11206 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1181925 |
Safety | Yes |
Health | Yes |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2017-02-13 |
Case Closed | 2019-08-27 |
Related Activity
Type | Complaint |
Activity Nr | 1181925 |
Safety | Yes |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100212 A02 |
Issuance Date | 2017-08-03 |
Current Penalty | 2485.0 |
Initial Penalty | 3585.0 |
Final Order | 2017-09-07 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible. Location: 175 Bogart Street, Brooklyn, NY. Machine Shop Area. a) The Wilton Square Wheel Belt Grinder, Model number 4103 used in the machine shop area had no guard. On or about 02/13/2017. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19100305 G02 II |
Issuance Date | 2017-08-03 |
Current Penalty | 1890.0 |
Initial Penalty | 2987.0 |
Final Order | 2017-09-07 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: LOCATION: 175 Bogart Street, Brooklyn, NY. Machine Shop Area. a) Flexible cord on the Wilton Square Wheel Belt Grinder, Model number 4103 was frayed and spliced together and patched with electrical tape. On or about 2/13/2017. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19100305 B02 I |
Issuance Date | 2017-08-03 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-09-07 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: Location: 175 Bogart Street, Brooklyn, NY. Work Shop Area. a) Electrical junction box cover was loose with a missing screw and live electrical wires inside the box were exposed. On or about 02/13/2017. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100305 J01 I |
Issuance Date | 2017-08-03 |
Current Penalty | 1875.0 |
Initial Penalty | 2987.0 |
Final Order | 2017-09-07 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located had live parts normally exposed to employee contact: Location: 175 Bogart Street, Brooklyn, NY. Machine Shop Area. a) Electrical toggle switch was removed from the Wilton Square Wheel Belt Grinder, Model number 4103 box and replaced with a single pole wall light fixture switch. The switch was patched with red electrical tape. On or about 02/13/2017. |
Inspection Type | Referral |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2013-12-11 |
Emphasis | L: FALL, L: GUTREH |
Case Closed | 2017-09-22 |
Related Activity
Type | Referral |
Activity Nr | 865352 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260303 B01 |
Issuance Date | 2014-02-06 |
Current Penalty | 1600.0 |
Initial Penalty | 1600.0 |
Final Order | 2014-04-14 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.303(b)(1): Grinding machines shall be equipped with safety guards in conformance with the requirements of American National Standards Institute, B7.1-1970, Safety Code for the Use, Care and Protection of Abrasive Wheels, and paragraph (d) of this section. Location: 150 Prince St., New York, NY. a) Employer failed to ensure that the DeWalt grinder utilized by an employee was equipped with protective guards; on or about 12/11/13. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260404 B01 I |
Issuance Date | 2014-02-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-04-14 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors. Location: 150 Prince St., New York, NY. a) Employer did not ensure that the DeWalt grinder powered by an extension cord was provided with a GFCI or an assured equipment program; on or about 12/11/13. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3193107707 | 2020-05-01 | 0202 | PPP | 333 Scholes Street Suite 203, BROOKLYN, NY, 11206 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 28 Mar 2025
Sources: New York Secretary of State