Inspection Type |
Fat/Cat
|
Scope |
Complete
|
Safety/Health |
Safety
|
Emphasis |
L: FALL, L: GUTREH
|
Case Closed |
2019-07-31
|
Related Activity
Type |
Accident |
Activity Nr |
871414 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2014-06-24 |
Abatement Due Date |
2014-08-11 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Contest Date |
2014-08-01 |
Final Order |
2015-02-06 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury: Location: entire site On or about: 1/31/14 a) Employees were exposed to hazards including unsafe demolition activities, lack of machine guarding and electrical hazards. The employees were not provided with general safety and health training. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260300 B01 |
Issuance Date |
2014-06-24 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Contest Date |
2014-08-01 |
Final Order |
2015-02-06 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.300(b)(1): When power operated tools are designed to accommodate guards, they were not equipped with such guards when in use: location: renovation area on or about: 1/31/14 a) Employees, engaged in renovation work, were using a Ridgid Compound Miter Saw, model R412, to cut wood. The point of operation guard was missing, exposing the metal blade. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 I |
Issuance Date |
2014-06-24 |
Abatement Due Date |
2014-07-07 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Contest Date |
2014-08-01 |
Final Order |
2015-02-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors: location: renovation area on or about: 01/31/14 a) Employees were using electrical equipment, including a Makita sander, that was plugged into extension cords. The employees were not provided with GFCI protection or an assured equipment grounding conductor program. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2014-06-24 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Contest Date |
2014-08-01 |
Final Order |
2015-02-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent and continuous: location: renovation area on or about: 01/31/14 a) Employees were using an extension cord to power electrical equipment, including a Ridgid abrasive cut-off machine. The extension cord was missing a grounding pin. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260405 G02 III |
Issuance Date |
2014-06-24 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Contest Date |
2014-08-01 |
Final Order |
2015-02-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iii): Splices. Flexible cords were not used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger were not repaired so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced: location: renovation area on or about: 01/31/14 a) Employees were using a spliced extension cord to power electrical equipment, including a Ridgid abrasive cut-off machine. The cord used for the splice did not have a grounding wire or pin and did not have the outer sheath properties of the original cord. Additionally, there was approximately two inches of the inner wires exposed. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19260405 B01 |
Issuance Date |
2014-06-24 |
Abatement Due Date |
2014-07-07 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Contest Date |
2014-08-01 |
Final Order |
2015-02-06 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(b)(1): Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed. Unused openings in cabinets, boxes, and fittings also were not effectively closed: location: renovation area on or about: 1/31/14 a) Employees were using a duplex outlet that was no longer attached to metal conduit to energize electrical equipment, including a Ridgid abrasive cut-off machine. The wires going from the conduit to the duplex outlet were not protected from abrasion. |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19260501 C |
Issuance Date |
2014-06-24 |
Abatement Due Date |
2014-07-07 |
Current Penalty |
4000.0 |
Initial Penalty |
7000.0 |
Contest Date |
2014-08-01 |
Final Order |
2015-02-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(c): When employees were exposed to falling objects, the employer did not implement one of the following measures; -1 Erect toeboards, screens, or guardrail systems to prevent objects from falling from higher levels; or, -2 Erect a canopy structure; or -3 Barricade the area to which objects could fall, prevent employees from entering the barricaded area, and keep objects away from the edge of the higher level: location: renovation area on or about: 1/10/14 a) Employees, engaged in commercial renovation activities, were working in the vicinity of an air conditioning condenser that was being removed from the ceiling. Measures were not taken to protect the employees from being struck by the condenser. |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19261053 B08 |
Issuance Date |
2014-06-24 |
Abatement Due Date |
2014-07-07 |
Current Penalty |
4000.0 |
Initial Penalty |
7000.0 |
Contest Date |
2014-08-01 |
Final Order |
2015-02-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(8): Ladders placed in any location where they can be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, shall be secured to prevent accidental displacement, or a barricade shall be used to keep the activities or traffic away from the ladder: location: renovation area on or about: 1/10/14 a) An employees was standing on a 10' metal A-frame ladder while removing an air conditioning condenser. The ladder was not secured nor was the area barricaded. |
|
|