Search icon

D & G RECYCLING, LLC

Company Details

Name: D & G RECYCLING, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 11 Sep 2008 (17 years ago)
Entity Number: 3719427
ZIP code: 12804
County: Warren
Place of Formation: New York
Address: 913 B BAY ROAD, QUEENSBURY, NY, United States, 12804

Agent

Name Role Address
GARY R FINGER Agent 913B BAY ROAD, QUEENSBURY, NY, 12804

DOS Process Agent

Name Role Address
C/O GARY R FINGER DOS Process Agent 913 B BAY ROAD, QUEENSBURY, NY, United States, 12804

Filings

Filing Number Date Filed Type Effective Date
141031006129 2014-10-31 BIENNIAL STATEMENT 2014-09-01
121009006169 2012-10-09 BIENNIAL STATEMENT 2012-09-01
100917002289 2010-09-17 BIENNIAL STATEMENT 2010-09-01
090121000700 2009-01-21 CERTIFICATE OF PUBLICATION 2009-01-21
080911000767 2008-09-11 ARTICLES OF ORGANIZATION 2008-09-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343788444 0213100 2019-02-15 125/127 RIVER STREET, QUEENSBURY, NY, 12804
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2019-02-15
Emphasis N: DUSTEXPL
Case Closed 2022-11-14

Related Activity

Type Inspection
Activity Nr 1303557
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2019-02-26
Abatement Due Date 2019-03-18
Current Penalty 2250.0
Initial Penalty 4168.0
Final Order 2019-04-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing or amputation hazard(s) during operation of a downstroke baler. (a) Bubblewrap/cardboard baling area: On or prior to 2/15/19, Piqua HD 2200 downstroke baler did not have a functioning sliding interlocked gate, in that the ram would operate without the loading chamber gate in the down position.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100028 B01 I
Issuance Date 2019-02-26
Abatement Due Date 2019-03-18
Current Penalty 2250.0
Initial Penalty 3334.0
Final Order 2019-04-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: (a) Densifier process area: On or prior to 2/15/19, the densifier material loading platform was not equipped with a guardrail or equivalent fall protection at the bin unloading area, exposing employees to an 8 foot fall hazard when the forklift and bin was not in position.
343117123 0213100 2018-04-26 125/127 RIVER STREET, QUEENSBURY, NY, 12804
Inspection Type Referral
Scope Partial
Safety/Health Health
Case Closed 2018-11-09

Related Activity

Type Referral
Activity Nr 1329912
Health Yes
Type Inspection
Activity Nr 1303557
Safety Yes
343035572 0213100 2018-03-22 125/127 RIVER STREET, QUEENSBURY, NY, 12804
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2018-03-22
Emphasis L: FORKLIFT, N: DUSTEXPL
Case Closed 2019-05-30

Related Activity

Type Inspection
Activity Nr 1311712
Health Yes
Type Complaint
Activity Nr 1319808
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2018-08-13
Abatement Due Date 2018-09-17
Current Penalty 1625.0
Initial Penalty 2772.0
Final Order 2018-09-18
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which is free from recognized hazards that were likely to cause death or serious physical harm to employees in that employees were exposed to dust explosion, deflagration or other fire hazards from hazards from dust collectors being located inside a building: (a) At the workplace -- On or prior to 3/22/18, the AGET Dustkop FT64-D1-SP dust collector(s) were located inside the building and the dust collector and ductwork was not equipped with explosion and deflagration protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100022 A01
Issuance Date 2018-08-13
Abatement Due Date 2018-11-30
Current Penalty 1625.0
Initial Penalty 2217.0
Final Order 2018-09-18
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms and walking-working surfaces were not kept clean, orderly and in sanitary condition. (a) At the workplace -- On or prior to 3/22/18, hazardous accumulations of combustible dust were present on mezzanine area(s), overhead structural steel, pipes, and other horizontal surfaces above/around the dust collector(s) in the northeast corner of the building.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100178 P01
Issuance Date 2018-08-13
Abatement Due Date 2018-08-31
Current Penalty 1625.0
Initial Penalty 2217.0
Final Order 2018-09-18
Nr Instances 2
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) (a) At the worksite -- On or prior to 3/22/18, Daewoo GC25S was in operation with tires in need of replacement. (b) At the worksite -- On or prior to 3/22/18, Clark ECG25 was in operation with tires in need of replacement, damaged lighting, and malfunctioning forward/reverse.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2018-08-13
Abatement Due Date 2018-08-31
Current Penalty 1625.0
Initial Penalty 2772.0
Final Order 2018-09-18
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) At the facility -- On or prior to 3/22/18, the barrier guard (gate) on Piqua HD 2200 downstroke baler was not functional, exposing employees to caught-in, crushing, or amputation hazards during operation.
Citation ID 02001
Citaton Type Other
Standard Cited 19100178 L06
Issuance Date 2018-08-13
Abatement Due Date 2018-09-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-09-18
Nr Instances 3
Nr Exposed 7
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): (a) At the facility -- On or prior to 3/22/18, the employer did not certify that operators of the Daewoo GC25S and Clark ECG25 forklifts were trained and evaluated in safe operation.
Citation ID 02002
Citaton Type Other
Standard Cited 19100303 B02
Issuance Date 2018-08-13
Abatement Due Date 2018-08-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-09-18
Nr Instances 1
Nr Exposed 7
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) At the facility, near the grinding machine -- On or about 3/22/18, a consumer grade 120V, 15A relocatable power tap (power strip) was used to provide power to electrical equipment in the area. The power strip is not approved for this service in that it is not designed for industrial use where it may be subjected to physical damage.

Date of last update: 10 Mar 2025