343788444
|
0213100
|
2019-02-15
|
125/127 RIVER STREET, QUEENSBURY, NY, 12804
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-02-15
|
Emphasis |
N: DUSTEXPL
|
Case Closed |
2022-11-14
|
Related Activity
Type |
Inspection |
Activity Nr |
1303557 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2019-02-26 |
Abatement Due Date |
2019-03-18 |
Current Penalty |
2250.0 |
Initial Penalty |
4168.0 |
Final Order |
2019-04-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing or amputation hazard(s) during operation of a downstroke baler. (a) Bubblewrap/cardboard baling area: On or prior to 2/15/19, Piqua HD 2200 downstroke baler did not have a functioning sliding interlocked gate, in that the ram would operate without the loading chamber gate in the down position. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100028 B01 I |
Issuance Date |
2019-02-26 |
Abatement Due Date |
2019-03-18 |
Current Penalty |
2250.0 |
Initial Penalty |
3334.0 |
Final Order |
2019-04-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: (a) Densifier process area: On or prior to 2/15/19, the densifier material loading platform was not equipped with a guardrail or equivalent fall protection at the bin unloading area, exposing employees to an 8 foot fall hazard when the forklift and bin was not in position. |
|
|
343117123
|
0213100
|
2018-04-26
|
125/127 RIVER STREET, QUEENSBURY, NY, 12804
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Case Closed |
2018-11-09
|
Related Activity
Type |
Referral |
Activity Nr |
1329912 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1303557 |
Safety |
Yes |
|
|
343035572
|
0213100
|
2018-03-22
|
125/127 RIVER STREET, QUEENSBURY, NY, 12804
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-03-22
|
Emphasis |
L: FORKLIFT, N: DUSTEXPL
|
Case Closed |
2019-05-30
|
Related Activity
Type |
Inspection |
Activity Nr |
1311712 |
Health |
Yes |
|
Type |
Complaint |
Activity Nr |
1319808 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2018-08-13 |
Abatement Due Date |
2018-09-17 |
Current Penalty |
1625.0 |
Initial Penalty |
2772.0 |
Final Order |
2018-09-18 |
Nr Instances |
1 |
Nr Exposed |
7 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which is free from recognized hazards that were likely to cause death or serious physical harm to employees in that employees were exposed to dust explosion, deflagration or other fire hazards from hazards from dust collectors being located inside a building: (a) At the workplace -- On or prior to 3/22/18, the AGET Dustkop FT64-D1-SP dust collector(s) were located inside the building and the dust collector and ductwork was not equipped with explosion and deflagration protection. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2018-08-13 |
Abatement Due Date |
2018-11-30 |
Current Penalty |
1625.0 |
Initial Penalty |
2217.0 |
Final Order |
2018-09-18 |
Nr Instances |
1 |
Nr Exposed |
7 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms and walking-working surfaces were not kept clean, orderly and in sanitary condition. (a) At the workplace -- On or prior to 3/22/18, hazardous accumulations of combustible dust were present on mezzanine area(s), overhead structural steel, pipes, and other horizontal surfaces above/around the dust collector(s) in the northeast corner of the building. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100178 P01 |
Issuance Date |
2018-08-13 |
Abatement Due Date |
2018-08-31 |
Current Penalty |
1625.0 |
Initial Penalty |
2217.0 |
Final Order |
2018-09-18 |
Nr Instances |
2 |
Nr Exposed |
7 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) (a) At the worksite -- On or prior to 3/22/18, Daewoo GC25S was in operation with tires in need of replacement. (b) At the worksite -- On or prior to 3/22/18, Clark ECG25 was in operation with tires in need of replacement, damaged lighting, and malfunctioning forward/reverse. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2018-08-13 |
Abatement Due Date |
2018-08-31 |
Current Penalty |
1625.0 |
Initial Penalty |
2772.0 |
Final Order |
2018-09-18 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) At the facility -- On or prior to 3/22/18, the barrier guard (gate) on Piqua HD 2200 downstroke baler was not functional, exposing employees to caught-in, crushing, or amputation hazards during operation. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100178 L06 |
Issuance Date |
2018-08-13 |
Abatement Due Date |
2018-09-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-09-18 |
Nr Instances |
3 |
Nr Exposed |
7 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): (a) At the facility -- On or prior to 3/22/18, the employer did not certify that operators of the Daewoo GC25S and Clark ECG25 forklifts were trained and evaluated in safe operation. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100303 B02 |
Issuance Date |
2018-08-13 |
Abatement Due Date |
2018-08-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-09-18 |
Nr Instances |
1 |
Nr Exposed |
7 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) At the facility, near the grinding machine -- On or about 3/22/18, a consumer grade 120V, 15A relocatable power tap (power strip) was used to provide power to electrical equipment in the area. The power strip is not approved for this service in that it is not designed for industrial use where it may be subjected to physical damage. |
|
|