Search icon

GRAND GABLE SIDING INC.

Company Details

Name: GRAND GABLE SIDING INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 06 Oct 2008 (17 years ago)
Date of dissolution: 29 Jun 2021
Entity Number: 3728900
ZIP code: 12047
County: Albany
Place of Formation: New York
Address: 1212 WATERSIDE WAY, COHOES, NY, United States, 12047

Shares Details

Shares issued 100

Share Par Value 0.01

Type PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 1212 WATERSIDE WAY, COHOES, NY, United States, 12047

Agent

Name Role Address
JEAN R. MCGRATH Agent 65 MASTEN AVE, COHOES, NY, 12047

Chief Executive Officer

Name Role Address
JERN MCGRATH Chief Executive Officer 1212 WATERSIDE WAY, COHOES, NY, United States, 12047

History

Start date End date Type Value
2013-03-08 2022-02-07 Address 1212 WATERSIDE WAY, COHOES, NY, 12047, USA (Type of address: Chief Executive Officer)
2013-03-08 2022-02-07 Address 1212 WATERSIDE WAY, COHOES, NY, 12047, USA (Type of address: Service of Process)
2008-10-06 2021-06-29 Shares Share type: PAR VALUE, Number of shares: 100, Par value: 0.01
2008-10-06 2022-02-07 Address 65 MASTEN AVE, COHOES, NY, 12047, USA (Type of address: Registered Agent)
2008-10-06 2013-03-08 Address 65 MASTEN AVE, COHOES, NY, 12047, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
220207000066 2021-06-29 CERTIFICATE OF DISSOLUTION-CANCELLATION 2021-06-29
130308002186 2013-03-08 BIENNIAL STATEMENT 2012-10-01
081006000474 2008-10-06 CERTIFICATE OF INCORPORATION 2008-10-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340856905 0213100 2015-08-18 195 COHOES AVENUE, GREEN ISLAND, NY, 12183
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-08-18
Emphasis L: FALL, P: FALL
Case Closed 2017-09-06

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2015-09-15
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-11-24
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: a) Job-Site - On or about August 18, 2015, employees were exposed to fall hazards when working in Genie S-40 aerial lifts without wearing a body belt and/or lanyard attached to the boom or basket approximately 20 feet in height from the ground.
334108222 0213100 2012-05-02 STONEGATE APARTMENTS VALLEY VIEW ROAD, RENSSELAER, NY, 12144
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2012-05-02
Emphasis L: FALL
Case Closed 2015-05-12

Related Activity

Type Inspection
Activity Nr 410663
Safety Yes
Type Inspection
Activity Nr 411223
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260403 B02
Issuance Date 2012-07-23
Current Penalty 1020.0
Initial Penalty 1020.0
Final Order 2012-08-20
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) Building 4, South Side - on or about May 5, 2012 - electric tools were plugged into wall outlets that were not installed in accordance to its listing and labeling requirements. The final installation of these outlets had not been completed.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260405 B02
Issuance Date 2012-07-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-08-20
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers: (a) Building 4, South Side - on or about May 5, 2012 - electric tools were plugged into wall outlets that were not provided with covers.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2012-07-23
Current Penalty 1020.0
Initial Penalty 1020.0
Final Order 2012-08-20
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: (a) Building 4, South Side - on or about May 5, 2012 - electric tools were not protected by a Ground Fault Circuit Inturrupter (GFCI).