Search icon

COSTANZA SIDING INC

Company Details

Name: COSTANZA SIDING INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 20 Oct 2008 (17 years ago)
Entity Number: 3733602
ZIP code: 11763
County: Suffolk
Place of Formation: New York
Address: 2102 KNICKERBOCKER AVE, MEDFORD, NY, United States, 11763

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
C/O NESTOR COSTANZA DOS Process Agent 2102 KNICKERBOCKER AVE, MEDFORD, NY, United States, 11763

Chief Executive Officer

Name Role Address
NESTOR F. COSTANZA Chief Executive Officer 2102 KNICKERBOCKER AVE, MEDFORD, NY, United States, 11763

Filings

Filing Number Date Filed Type Effective Date
121026002294 2012-10-26 BIENNIAL STATEMENT 2012-10-01
101208002088 2010-12-08 BIENNIAL STATEMENT 2010-10-01
081020000336 2008-10-20 CERTIFICATE OF INCORPORATION 2008-10-20

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
214500 TO INVOICED 2013-04-30 206.5 Tow Truck Trust Fund Reimbursement
214501 SV VIO INVOICED 2013-04-29 1000 SV - Vehicle Seizure

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340663343 0214700 2015-05-22 CHURCH ST., BAYPORT, NY, 11705
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2015-05-22
Emphasis L: FALL, P: FALL
Case Closed 2018-11-20

Related Activity

Type Inspection
Activity Nr 1066348
Safety Yes
Type Inspection
Activity Nr 1066365
Safety Yes
Type Inspection
Activity Nr 1065255
Safety Yes
Type Inspection
Activity Nr 1065262
Safety Yes
Type Inspection
Activity Nr 1066343
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2015-06-19
Abatement Due Date 2015-06-25
Current Penalty 1320.0
Initial Penalty 1320.0
Final Order 2015-11-03
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite: Employees working directly under ongoing overhead siding work were not using head protection; on or about 5/22/15. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2015-06-19
Abatement Due Date 2015-07-01
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-11-03
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Worksite: Employees were doing siding work on a residential building from the roof of the first story approximately 10 ft. above the ground and had not been trained in recognizing and minimizing fall hazards; on or about 5/22/15. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2015-06-19
Abatement Due Date 2015-06-25
Current Penalty 4000.0
Initial Penalty 4000.0
Final Order 2015-11-03
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite: Employees were doing siding work from the roof of a residential building approximately 10 ft. above the ground and did not have fall protection; on or about 5/22/15. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
339010043 0214700 2013-04-10 LEE GRAY COURT, GLEN COVE, NY, 11542
Inspection Type Prog Other
Scope Partial
Safety/Health Safety
Close Conference 2013-04-10
Emphasis P: FALL, L: FALL
Case Closed 2017-02-13

Related Activity

Type Inspection
Activity Nr 900751
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-09-03
Abatement Due Date 2013-09-09
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-10-07
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite, Lee Gray Court, Glen Cove, NY- Employees were working on a roof with a pitch of approximately 6/12, at a height of approximately 20 feet above the ground below without being protected from a fall; on or about 4/10/13. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-09-03
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-10-07
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Worksite, Lee Gray Court, Glen Cove, roof of residence- Employees were accessing the roof of a two story residence by way of an extension ladder which extended approximately one foot above the upper landing surface; on or about 4/10/13. b) Worksite, Lee Gray Court, Glen Cove- roof of residence- Employees were accessing the roof of the garage attached to the residence by way of an extension ladder which extended approximately one foot above the upper landing surface; on or about 4/10/13. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2013-09-03
Abatement Due Date 2013-09-09
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2013-10-07
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) Worksite, Lee Gray Court, Glen Cove, NY- Employees using pneumatic nails gun to install plywood sheathing and roofing shingles to a residential roof were not wearing eye protection; on or about 4/10/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
2400223 Intrastate Non-Hazmat 2013-04-25 - - 1 1 Private(Property)
Legal Name COSTANZA SIDING INC
DBA Name -
Physical Address 2102 KNICKERBOCKER AVE, MEDFORD, NY, 11763, US
Mailing Address 2102 KNICKERBOCKER AVE, MEDFORD, NY, 11763, US
Phone (631) 764-4377
Fax -
E-mail -

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 27 Mar 2025

Sources: New York Secretary of State