Search icon

J & M STUCCO, INC.

Company Details

Name: J & M STUCCO, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 30 Oct 2008 (16 years ago)
Entity Number: 3737565
ZIP code: 11590
County: Nassau
Place of Formation: New York
Address: JUAN CARRAS, 167 ELIZABETH ST, WESTBURY, NY, United States, 11590
Principal Address: 167 ELIZABETH ST, PO BOX 869, WESTBURY, NY, United States, 11590

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
JUAN CARRAS Chief Executive Officer 167 ELZAZBETH ST, WESTBURY, NY, United States, 11590

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent JUAN CARRAS, 167 ELIZABETH ST, WESTBURY, NY, United States, 11590

History

Start date End date Type Value
2008-10-30 2010-10-27 Address 167 ELIZABETH STREET, WESTBURY, NY, 11590, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
101027002307 2010-10-27 BIENNIAL STATEMENT 2010-10-01
081030000207 2008-10-30 CERTIFICATE OF INCORPORATION 2008-10-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
335068581 0214700 2012-06-29 4900 HEMPSTEAD TURNPIKE, BETHPAGE, NY, 11714
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-06-29
Emphasis L: FALL, N: CTARGET
Case Closed 2017-12-18

Related Activity

Type Inspection
Activity Nr 507218
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2012-12-20
Abatement Due Date 2012-12-27
Current Penalty 1500.0
Initial Penalty 2000.0
Final Order 2013-01-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, stucture, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a) Worksite, north side of building- Employees climbed the frames and crossbracing of a fabricated frame scaffold to access the 12' and 18' levels; on or about 06/29/12. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2012-12-20
Abatement Due Date 2012-12-27
Current Penalty 2100.0
Initial Penalty 2800.0
Final Order 2013-01-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Worksite- north side of building- Employee was working at the 18' level of a scaffold that had no guardrails; on or about 06/29/12. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2012-12-20
Abatement Due Date 2012-12-27
Current Penalty 2100.0
Initial Penalty 2800.0
Final Order 2013-01-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) Worksite, north side of building- Employee was working on the third level of a fabricated frame scaffold at the 18' level. The scaffold had only four planks installed. Two planks were missing, leaving an opening 18" wide; on or about 06/29/12. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.

Date of last update: 27 Mar 2025