346663826
|
0215000
|
2023-04-27
|
2033 OCEAN PKWY, BROOKLYN, NY, 11223
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-04-27
|
Case Closed |
2023-06-13
|
Related Activity
Type |
Inspection |
Activity Nr |
1666429 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1666442 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1564455 |
Safety |
Yes |
|
|
345644553
|
0215000
|
2021-11-16
|
2033 OCEAN PKWY, BROOKLYN, NY, 11223
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-11-16
|
Emphasis |
L: FALL, P: FALL
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2022-05-11 |
Current Penalty |
6381.0 |
Initial Penalty |
6381.0 |
Final Order |
2022-06-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: Location: 2033 Ocean Pkwy On or about: 16 November 2021 a) An employee used a air compressor that was missing a ground pin. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2022-05-11 |
Abatement Due Date |
2022-05-23 |
Current Penalty |
6381.0 |
Initial Penalty |
6381.0 |
Final Order |
2022-06-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Location: 2033 Ocean Pkwy. On or about: 16 November 2021 a) An employee was working on a roof and was not tied off, employee was exposed to a fall of 30 feet. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2022-05-11 |
Current Penalty |
6381.0 |
Initial Penalty |
6381.0 |
Final Order |
2022-06-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): The ladder extension was positioned such that deflection under a load, by itself, would cause the ladder to slip off its support: Location: 2033 Ocean Pkwy On or about: 16 November 2021 a) Employees accessed the roof by an extension ladder positioned such that deflection would cause it to slip off its support, employee was exposed to a fall of 30 feet. |
|
|
343940086
|
0214700
|
2019-04-15
|
615 S. WELLWOOD AVE., LINDENHURST, NY, 11757
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-04-15
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2022-11-07
|
Related Activity
Type |
Inspection |
Activity Nr |
1394086 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261053 B05 I |
Issuance Date |
2019-10-09 |
Current Penalty |
3126.0 |
Initial Penalty |
3126.0 |
Final Order |
2019-11-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder. a) Worksite, 615 S.Wellwood Ave.,Lindenhurst, NY- Employees gained access to a roof using an extension ladder, extended approximately 25ft in length. The foot of the ladder was approximately 13ft away from the supporting structure; on or about 4/15/19. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
|
|
339748410
|
0214700
|
2014-04-28
|
1 RIPLEY LANE, OYSTER BAY, NY, 11771
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-04-28
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2015-11-30
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260095 A |
Issuance Date |
2014-09-15 |
Current Penalty |
1000.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-10-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a) Worksite - Employees were reinstalling wood trim and shingles around work area with a pneumatic nail gun without eye protection; on or about 04/28/2014. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-09-15 |
Abatement Due Date |
2014-09-23 |
Current Penalty |
1500.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-10-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite - Employees installing gutters on an approximate 6-12 pitch roof, approximately 20 feet above the ground, were not protected from falling; on or about 04/28/2014. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2014-09-15 |
Abatement Due Date |
2014-09-23 |
Current Penalty |
1500.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-10-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Worksite: Employees were accessing an approximate 6-12 pitch roof roof approximately 20 feet above the ground. The portable ladder used to access the roof extended approximately 12 inches above the landing surface; on, or about, 04/28/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
|
334015039
|
0215600
|
2012-04-19
|
250-05 VAN ZANDT AVE, LITTLE NECK, NY, 11362
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-04-19
|
Emphasis |
L: FALL
|
Case Closed |
2013-08-05
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2012-06-25 |
Current Penalty |
800.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-07-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: A). On or about 04/19/12, at the site of 250-05 Van Zandt Ave. Little Neck, NY Employees working at the site were in danger of head injury from falling objects such as, but not limited to tools and materials from other employees who on the roof. Protective helmets were not worn. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2012-06-25 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2012-07-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: A). on or about 04/19/12, at 250-05 Van Zandt Ave. Little Neck, NY Employees working on unprotective scaffolds were exposed to the hazard of falling approximately 12 ft to the ground below. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
|