Search icon

IACOVELLI BROTHERS CONTRACTING COMPANY, INC.

Company Details

Name: IACOVELLI BROTHERS CONTRACTING COMPANY, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 12 Mar 1973 (52 years ago)
Date of dissolution: 07 Sep 2018
Entity Number: 3738555
ZIP code: 14850
County: Tompkins
Place of Formation: New York
Address: 124 COMPTON RD, ITHACA, NY, United States, 14850

Shares Details

Shares issued 100

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
LAWRENCE IACOVELLI DOS Process Agent 124 COMPTON RD, ITHACA, NY, United States, 14850

Agent

Name Role Address
JAMES V. IACOVELLI Agent 148 KENDALL AVENUE, ITHACA, NY, 14850

Chief Executive Officer

Name Role Address
LAWRENCE IACOVELLI Chief Executive Officer 124 COMPTON RD, ITHACA, NY, United States, 14850

History

Start date End date Type Value
2013-03-14 2017-03-07 Address 142 ITHACA BEER DRIVE, ITHACA, NY, 14850, USA (Type of address: Principal Executive Office)
2013-03-14 2017-03-07 Address 142 ITHACA BEER DRIVE, ITHACA, NY, 14850, USA (Type of address: Service of Process)
2009-10-07 2013-03-14 Address 610 ELMIRA RD, ITHACA, NY, 14850, USA (Type of address: Principal Executive Office)
2009-10-07 2013-03-14 Address 610 ELMIRA RD, ITHACA, NY, 14850, USA (Type of address: Service of Process)
1973-03-12 2009-10-07 Address 148 KENDALL AVENUE, ITHACA, NY, 14850, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
180907000715 2018-09-07 CERTIFICATE OF DISSOLUTION 2018-09-07
170307006453 2017-03-07 BIENNIAL STATEMENT 2017-03-01
150302007413 2015-03-02 BIENNIAL STATEMENT 2015-03-01
130314006183 2013-03-14 BIENNIAL STATEMENT 2013-03-01
110401002511 2011-04-01 BIENNIAL STATEMENT 2011-03-01
091007002813 2009-10-07 BIENNIAL STATEMENT 2009-03-01
A56147-4 1973-03-12 CERTIFICATE OF INCORPORATION 1973-03-12

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340204965 0215800 2015-01-20 202 EDDY STREET, ITHACA, NY, 14850
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2015-01-20
Emphasis N: TRENCH
Case Closed 2015-03-11

Related Activity

Type Complaint
Activity Nr 932973
Safety Yes
Type Inspection
Activity Nr 1020536
Safety Yes
Type Inspection
Activity Nr 1020453
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2015-02-06
Abatement Due Date 2015-02-16
Current Penalty 0.0
Initial Penalty 1200.0
Final Order 2015-02-19
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) East side of building, on or about 1-20-15: Employees were working on a 9-1/2" single plank platform, on outrigger brackets attached to "Symons" forms, exposing the employees to a fall hazard of 4 feet. ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260651 C02
Issuance Date 2015-02-06
Abatement Due Date 2015-02-16
Current Penalty 0.0
Initial Penalty 1600.0
Final Order 2015-02-19
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) North side of building, on or about 1-20-15: Employees were removing "Symons" form panels in an excavation with the nearest egress ladder located 60 feet away. ABATEMENT CERTIFICATION MUST IS REQUIRED FOR THIS ITEM
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260651 J01
Issuance Date 2015-02-06
Abatement Due Date 2015-02-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-02-19
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(j)(1): Adequate protection was not provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from an excavation face: a) North, south, and east side of building, on or about 1-20-15: Employees were removing "Symons" form panels in an excavation up to 10 feet 5 inches deep, with loose rocks (shale) resting on the top of the bank. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2015-02-06
Current Penalty 0.0
Initial Penalty 1200.0
Final Order 2015-02-19
Nr Instances 2
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a) East side of building, excavation, on or about 1-20-15: Employees were using a folded step ladder that was not being used as designed or for its intended purpose.

Date of last update: 27 Mar 2025

Sources: New York Secretary of State