Name: | DAVID METALS, LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 12 Nov 2008 (16 years ago) |
Entity Number: | 3741621 |
ZIP code: | 10993 |
County: | Rockland |
Place of Formation: | New York |
Address: | 40-48 SAMSONDALE AVENUE, WEST HAVESTRAW, NY, United States, 10993 |
Plan Name | Plan Year | EIN/PN | Received | Sponsor | Total number of participants | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DAVID METALS LLC 401(K) PLAN | 2023 | 263710421 | 2024-10-02 | DAVID METALS LLC | 6 | |||||||||||||
|
||||||||||||||||||
DAVID METALS LLC 401(K) PLAN | 2022 | 263710421 | 2023-10-12 | DAVID METALS LLC | 6 | |||||||||||||
|
||||||||||||||||||
DAVID METALS LLC 401(K) PLAN | 2021 | 263710421 | 2022-10-03 | DAVID METALS LLC | 6 | |||||||||||||
|
||||||||||||||||||
DAVID METALS LLC 401(K) PLAN | 2020 | 263710421 | 2022-01-17 | DAVID METALS LLC | 6 | |||||||||||||
|
Name | Role | Address |
---|---|---|
DAVID METALS, LLC | DOS Process Agent | 40-48 SAMSONDALE AVENUE, WEST HAVESTRAW, NY, United States, 10993 |
Start date | End date | Type | Value |
---|---|---|---|
2008-11-12 | 2016-11-04 | Address | 9 CARLEY COURT, WEST NYACK, NY, 10994, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
161104006491 | 2016-11-04 | BIENNIAL STATEMENT | 2016-11-01 |
141113006717 | 2014-11-13 | BIENNIAL STATEMENT | 2014-11-01 |
121108006357 | 2012-11-08 | BIENNIAL STATEMENT | 2012-11-01 |
101209002674 | 2010-12-09 | BIENNIAL STATEMENT | 2010-11-01 |
090129000376 | 2009-01-29 | CERTIFICATE OF PUBLICATION | 2009-01-29 |
081112000209 | 2008-11-12 | ARTICLES OF ORGANIZATION | 2008-11-12 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339518888 | 0216000 | 2013-12-12 | 25 WEST WASHINGTON AVENUE, PEARL RIVER, NY, 10965 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 914764 |
Health | Yes |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Health |
Close Conference | 2013-06-25 |
Emphasis | N: LEAD, P: LEAD |
Case Closed | 2014-02-07 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100036 G02 |
Issuance Date | 2013-10-28 |
Current Penalty | 1000.0 |
Initial Penalty | 1200.0 |
Final Order | 2013-11-12 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. a) Inside Shop - Old Compactor Side of Building: Access to the front and rear exit doors was not maintained at 28 inches wide along all points of the exit route; on or about 6/25/13. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19100178 L01 I |
Issuance Date | 2013-10-28 |
Abatement Due Date | 2013-11-30 |
Current Penalty | 1000.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-11-12 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Entire Company: The employer did not ensure that employees who operated two propane forklifts were comptent to operate them as required by the standard; on or about 6/25/13. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19100178 L04 III |
Issuance Date | 2013-10-28 |
Abatement Due Date | 2013-11-30 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-11-12 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) Entire Company: An employee who used twp propane forklifts did not receive refresher training at least once every three years; on or about 6/25/13. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100141 A03 I |
Issuance Date | 2013-10-28 |
Current Penalty | 1000.0 |
Initial Penalty | 1200.0 |
Final Order | 2013-11-12 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed: a) Inside the Shop: Both employee bathrooms were kept in an unsanitary condition; on or about 6/25/13. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19100212 A03 II |
Issuance Date | 2013-10-28 |
Abatement Due Date | 2013-11-30 |
Current Penalty | 1800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-11-12 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Inside Shop: A hydraulic shear was used to cut/bend scrap metal and the point of operation was not guarded to prevent employee injury; on or about 9/27/13. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100157 C01 |
Issuance Date | 2013-10-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-11-12 |
Nr Instances | 1 |
Nr Exposed | 6 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Entire Company: Fire extinguishers were not mounted and identified; on or about 6/25/13. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19101025 L01 I |
Issuance Date | 2013-10-28 |
Abatement Due Date | 2013-11-30 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-11-12 |
Nr Instances | 1 |
Nr Exposed | 6 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025: a) Indoor Shop Area: Employees received and moved lead containing pipes into a storage area and employees were not informed of the content of Appendicies A and B of 29 CFR 1910.1025; on or about 6/25/13 |
Date of last update: 27 Mar 2025