Search icon

US DEMCO OF BROOKLYN INC.

Company Details

Name: US DEMCO OF BROOKLYN INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 31 Dec 2008 (16 years ago)
Entity Number: 3757829
ZIP code: 11219
County: Kings
Place of Formation: New York
Address: 5308 13TH AVE #111, BROOKLYN, NY, United States, 11219

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
US DEMCO OF BROOKLYN INC. DOS Process Agent 5308 13TH AVE #111, BROOKLYN, NY, United States, 11219

Chief Executive Officer

Name Role Address
SEKOU DIAKITE Chief Executive Officer 5308 13TH AVE #111, BROOKLYN, NY, United States, 11219

History

Start date End date Type Value
2019-11-27 2020-12-15 Address 5308 13TH AVE #111, BROOKLYN, NY, 11219, USA (Type of address: Service of Process)
2014-12-15 2019-11-27 Address 5308 13TH AVE, BROOKLYN, NY, 11219, USA (Type of address: Service of Process)
2013-01-15 2019-11-27 Address 886 LINDEN BLVD, BROOKLYN, NY, 11203, USA (Type of address: Chief Executive Officer)
2013-01-15 2019-11-27 Address 1813 58, BROOKLYN, NY, 11203, USA (Type of address: Principal Executive Office)
2013-01-15 2014-12-15 Address 5308 13TH AVE, H111, BROOKLYN, NY, 11219, USA (Type of address: Service of Process)
2008-12-31 2013-01-15 Address 1312 44TH STREET, #144, BROOKLYN, NY, 11219, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
230105002676 2023-01-05 BIENNIAL STATEMENT 2022-12-01
201215060218 2020-12-15 BIENNIAL STATEMENT 2020-12-01
191127060141 2019-11-27 BIENNIAL STATEMENT 2018-12-01
161207006526 2016-12-07 BIENNIAL STATEMENT 2016-12-01
141215006798 2014-12-15 BIENNIAL STATEMENT 2014-12-01
130115002096 2013-01-15 BIENNIAL STATEMENT 2012-12-01
081231000451 2008-12-31 CERTIFICATE OF INCORPORATION 2008-12-31

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2018-11-28 No data EAST 22 STREET, FROM STREET AVENUE I TO STREET AVENUE J No data Street Construction Inspections: CAR Re-Inspect Department of Transportation Joints sealed.
2018-08-31 No data EAST 22 STREET, FROM STREET AVENUE I TO STREET AVENUE J No data Street Construction Inspections: Post-Audit Department of Transportation Seal expansion joint between sidewalk & drop curb.
2018-06-22 No data 53 STREET, FROM STREET 15 AVENUE TO STREET 16 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation CURB IN GOOD CONDITION, EXPANSION JIONTS SEALED
2018-05-27 No data 45 STREET, FROM STREET 15 AVENUE TO STREET 16 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Curb is ok, expansion joints sealed. In front of 1548 45 Street.
2018-05-27 No data 49 STREET, FROM STREET 15 AVENUE TO STREET 16 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Curb is ok, expansion joints sealed. In front of 1564 49 Street
2018-05-27 No data 49 STREET, FROM STREET 14 AVENUE TO STREET 15 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Steel face curb ok, expansion joints sealed. In front of 1420 49 Street
2018-05-10 No data MAC DOUGAL STREET, FROM STREET BROADWAY TO STREET MOTHER GASTON BOULEVARD No data Street Construction Inspections: Post-Audit Department of Transportation pass, new curb ,....
2017-10-29 No data 47 STREET, FROM STREET 19 AVENUE TO STREET BEND No data Street Construction Inspections: Post-Audit Department of Transportation curb
2017-04-19 No data 17 AVENUE, FROM STREET 58 STREET TO STREET 59 STREET No data Street Construction Inspections: Post-Audit Department of Transportation sidewalk
2017-03-01 No data 53 STREET, FROM STREET 15 AVENUE TO STREET 16 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation curb

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340047778 0215000 2014-10-24 168 20TH STREET, BROOKLYN, NY, 11232
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2014-10-24
Emphasis L: FALL
Case Closed 2018-03-13

Related Activity

Type Inspection
Activity Nr 1004477
Safety Yes
Type Inspection
Activity Nr 1004532
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2015-03-06
Current Penalty 2520.0
Initial Penalty 2520.0
Final Order 2015-04-02
Nr Instances 2
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. Location: 168 20th Street Brooklyn, NY. On or about: 10/24/14 a) Employees walked and worked next to unprotected floor holes located at the first floor.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B01
Issuance Date 2015-03-06
Current Penalty 6160.0
Initial Penalty 6160.0
Final Order 2015-04-02
Nr Instances 2
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: 168 20th Street Brooklyn, NY. On or about: 10/24/14. a) Employees were working at unprotected floor edges while exposed to falls in excess of 10 feet. US Demco of Brooklyn Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(1),which was contained in OSHA inspection number 956998, citation number 2, item number 1 and was affirmed as a final order on 09/22/14, with respect to a workplace located at 50-54 Clarkson Avenue Brooklyn NY.
339569980 0215000 2014-01-31 50-54 CLARKSON AVE, BROOKLYN, NY, 11219
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2014-01-31
Emphasis L: FALL
Case Closed 2018-10-22

Related Activity

Type Complaint
Activity Nr 870776
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260025 A
Issuance Date 2014-06-27
Current Penalty 920.0
Initial Penalty 1600.0
Final Order 2014-07-28
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.25(a): Employer did not ensure scrap lumber with protruding nails, and all other debris, was kept cleared from work areas, passageways, and stairs, in and around buildings or other structures, during the course of construction, alteration, or repairs. Loaction: 50-54 Clarkson Ave, Brooklyn, NY throughout entire project. On or about January 31, 2014, a). Employees were engaged in the demolition of a three unit, three story residential project and while moving from building to building, did not clear the areas of debris from the work surfaces, passageways, stairways or ground around site. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 B01 II
Issuance Date 2014-06-27
Current Penalty 1632.0
Initial Penalty 2800.0
Final Order 2014-07-28
Nr Instances 2
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(ii): Employer did not ensure, on a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets, which were not a part of the permanent wiring of the building or structure and which are in use by employees, had approved ground fault circuit interrupers for personal protection. LOCATION: 50-54 Clarkson Ave, Brooklyn, NY throughout the project. On or about January 31, 2014, a). Employees were using portable double insulated Sawz-All power saws to demolish three, 3 story wood framed dwellings. The employees using the power tools were not protected from electrical shock by the use of Ground Fault Circiut inturrupters, (GCFI) attached between the Portable Generator and the Power tools. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B06
Issuance Date 2014-06-27
Current Penalty 1632.0
Initial Penalty 2800.0
Final Order 2014-07-28
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(6): "Ramps, runways, and other walkways." Employer did not ensure each employee on ramps, runways, and other walkways were protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems. Loaction 50-54 Clarkson Ave, Brooklyn, NY 11219 On or About February 6, 2014 Employees had used a walk ramp made up of four (4) 3x6 wood planks, between building 3 at the second floor and building 2 at the second floor. Employees were traversing this walkway from building 3, while pushing wheel barrows loaded with construction debris to be dumped from the second floor of building 2. Guardrails were not installed on each side of the ramp. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260502 K04
Issuance Date 2014-06-27
Current Penalty 1632.0
Initial Penalty 2800.0
Final Order 2014-07-28
Nr Instances 4
Nr Exposed 11
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(k)(4): Employer did not ensure the implementation of the fall protection plan was supervised by a competent person. Location: 50-54 Clarkson Ave, Brooklyn, NY 11219, throughout project. On or about January 31, 2014 a). Employees were engaged in the demolition/deconstruction of a three unit, three story residential project. Employees were not protected from falls to the surface below by any means, and employer did nothing to implement the plan or monitor the employees movements. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260852 A
Issuance Date 2014-06-27
Current Penalty 920.0
Initial Penalty 1600.0
Final Order 2014-07-28
Nr Instances 1
Nr Exposed 12
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.852(a): No material shall be dropped to any point lying outside the exterior walls of the structure unless the area is effectively protected. 50-54 Clarkson Ave, Brooklyn, NY front part of project. On or about February 6, 2014 Employees were utilizing a wheel barrow to dump demolition materials from the second floor of a structure to the dumpster on the street below. The area below was not protected or guarded against person entering the area with falling debris. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260854 E
Issuance Date 2014-06-27
Current Penalty 1632.0
Initial Penalty 2800.0
Final Order 2014-07-28
Nr Instances 6
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.854(e): Employer did not ensure Floor openings within 10 feet of any wall being demolished were planked solid, except when employees are kept out of the area below. Location 50-54 Clarkson Ave, Brooklyn, NY 11219 On or about January 31, 2014 a). Employees were demolishing the walls and ceilings of a three story wood framed dwelling while additional employees were demolishing the interior wall coverings on the floors below. Employees working above did not fully plank or cover the stairwell openings to protect those workers below. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Citation ID 01007
Citaton Type Serious
Standard Cited 19260855 C
Issuance Date 2014-06-27
Current Penalty 1632.0
Initial Penalty 2800.0
Final Order 2014-07-28
Nr Instances 6
Nr Exposed 11
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.855(c): Employer did not ensure Safe walkways, not less than 18 inches wide, formed of planks not less than 2 inches thick if wood, or of equivalent strength if metal, were provided and used by workmen when necessary to enable them to reach any point without walking upon exposed beams. Location: 50-54 Clarkson Ave, Brooklyn, NY 11219. Buildings 2 and 3. On or about January 31, 2014, and again on February 6, 2014. a). Employees were demolishing three three story wood framed residential structures and did not install or utilize any type of planking during the demolition of the floor surfaces to enable them to reach any point without walking along the exposed floor joists, ceiling joists, or beams. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260501 B01
Issuance Date 2014-06-27
Current Penalty 22500.0
Initial Penalty 28000.0
Final Order 2014-07-28
Nr Instances 3
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Employer did not ensure each employee on a walking/working surface having an unprotected side or edge which was six or more feet (1.8m) or more above a lower level was protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest system. Location 50-54 Clarkson Ave, Brooklyn, NY On or about January 31, 2014 a. Employees were engaged in the demolition/deconstruction of a three unit, three story residential project and were not protected from falls by any means, in that, the roof and side walls were demolished down to the walking level and edges were left exposed to the surface in excess of 10 feet below, stairwell openings were unprotected, and no Personal Fall Arrest System was utilized. On or about February 6, 2014; a). Employees engaged in demolishing building 1 on the site were exposed to falls in excess of 10 feet to the surface below by not utilizing personal fall protection. b). Employees working along the edge of building 2 were exposed to falls in excess of 10 feet to the surface below by not utilizing personal fall protection. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Citation ID 03001
Citaton Type Other
Standard Cited 19260404 F06
Issuance Date 2014-06-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-07-28
Nr Instances 2
Nr Exposed 11
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): Employer did not ensure the path to ground from circuits, equipment, or enclosures was permanent and continuous: Location 50-54 Clarkson Ave, Brooklyn, NY entire project. On or about January 31, 2014 a). Employees were using hand held double insulated portable power tools (Milwaukee Brand Sawz-All) to demolish/deconstruct three, 3 story residential structures. The employees were utilizing flexible power cords to draw electrical power from a portable generator on site. The temporary flexible cords did not have a continuous path to ground between the tool and the generator because they were missing their ground pins. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.