Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-05-25
|
Emphasis |
P: FALL, L: FALL
|
Case Closed |
2022-08-09
|
Related Activity
Type |
Inspection |
Activity Nr |
1150157 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1150143 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-07-21 |
Abatement Due Date |
2016-07-27 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-08-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite, 28 Dune Rd., Quogue, NY: Employee installing glass doors and windows on a residential home was walking on the edge of a second floor story landing approximately 10ft. above the ground below without fall protection; on or about 5/25/2016. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2016-07-21 |
Abatement Due Date |
2016-07-27 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-08-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Worksite, 28 Dune Rd., Quogue, NY - Employees were using a folding stepladder to gain access to the second story landing in order to install glass doors and windows; on or about 5/25/2016. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261060 A |
Issuance Date |
2016-07-21 |
Abatement Due Date |
2016-07-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: a)Worksite, 28 Dune Rd., Quogue, NY: Employees using ladder to access the second story landing of a residential home were not provided with ladder training; on or about 5/25/2016 Note: The employer is required to provide abatement certification for this item in accordance with 29 CFR 1903.19. |
|
|