Search icon

BRIGHTON CONTRACTORS NYC INC.

Company Details

Name: BRIGHTON CONTRACTORS NYC INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 18 Feb 2009 (16 years ago)
Date of dissolution: 20 Oct 2014
Entity Number: 3776298
ZIP code: 11235
County: Kings
Place of Formation: New York
Address: 2538 E. 22ND STREET, BROOKLYN, NY, United States, 11235
Principal Address: 2538 EAST 22ND ST, BROOKLYN, NY, United States, 11235

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 2538 E. 22ND STREET, BROOKLYN, NY, United States, 11235

Chief Executive Officer

Name Role Address
SHU MING LI Chief Executive Officer 2538 EAST 22ND ST, BROOKLYN, NY, United States, 11235

History

Start date End date Type Value
2011-02-15 2013-11-07 Address 2538 EAST 22ND ST, BROOKLYN, NY, 11235, USA (Type of address: Principal Executive Office)

Filings

Filing Number Date Filed Type Effective Date
141020000663 2014-10-20 CERTIFICATE OF DISSOLUTION 2014-10-20
131107006703 2013-11-07 BIENNIAL STATEMENT 2013-02-01
110215003071 2011-02-15 BIENNIAL STATEMENT 2011-02-01
090218000659 2009-02-18 CERTIFICATE OF INCORPORATION 2009-02-18

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2013-08-09 No data SACKETT STREET, FROM STREET COLUMBIA STREET TO STREET HICKS STREET No data Street Construction Inspections: Post-Audit Department of Transportation s\w ok
2013-01-14 No data GRAND STREET, FROM STREET BOWERY TO STREET CHRYSTIE STREET No data Street Construction Inspections: Post-Audit Department of Transportation Water Works still working on ddc project. Area on sidewalk plated.
2012-06-21 No data GREENWICH STREET, FROM STREET CANAL STREET TO STREET HOLLAND TUNNEL ENTRANCE No data Street Construction Inspections: Active Department of Transportation boom truck
2012-05-24 No data GREENWICH STREET, FROM STREET CANAL STREET TO STREET HOLLAND TUNNEL ENTRANCE No data Street Construction Inspections: Active Department of Transportation barricads on r.w
2012-04-20 No data GREENWICH STREET, FROM STREET CANAL STREET TO STREET HOLLAND TUNNEL ENTRANCE No data Street Construction Inspections: Post-Audit Department of Transportation no boom truck on site
2012-03-07 No data GREENWICH STREET, FROM STREET CANAL STREET TO STREET HOLLAND TUNNEL ENTRANCE No data Street Construction Inspections: Active Department of Transportation No data
2011-12-15 No data GREENWICH STREET, FROM STREET CANAL STREET TO STREET HOLLAND TUNNEL ENTRANCE No data Street Construction Inspections: Active Department of Transportation No data
2011-10-19 No data GREENWICH STREET, FROM STREET CANAL STREET TO STREET HOLLAND TUNNEL ENTRANCE No data Street Construction Inspections: Active Department of Transportation No data
2011-10-12 No data GREENWICH STREET, FROM STREET CANAL STREET TO STREET HOLLAND TUNNEL ENTRANCE No data Street Construction Inspections: Active Department of Transportation No data
2011-10-09 No data GREENWICH STREET, FROM STREET CANAL STREET TO STREET HOLLAND TUNNEL ENTRANCE No data Street Construction Inspections: Active Department of Transportation no active work.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339582827 0215000 2014-02-10 125 PARK AVE, NEW YORK, NY, 10017
Inspection Type Prog Other
Scope Complete
Safety/Health Safety
Close Conference 2014-02-10
Emphasis L: FALL
Case Closed 2018-08-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2014-03-21
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-04-17
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked between the front uprights and the guardrail supports: a) The employer erected two 12 ft tall scaffolds for installing a decorative metal curtain along the 25 ft tall wall (18th floor lobby). The scaffold framings were 4 and 5 ft wide but the working platforms were only 20 inches wide, made of plywood nailed to 2by4 wood. Employees were exposed to falling 12 feet. Location: 125 Park Ave, New York, N.Y. On or about 2/10/2014 NOTE: BECAUSE THE EMPLOYER CORRECTED THIS ITEM DURING THE INSPECTION THE EMPLOYER IS NOT REQUIRED TO SUBMIT ABATEMENT CERTIFICATION NOR DOCUMENTATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2014-03-21
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-04-17
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): The employer did not ensure that scaffolds were erected, moved, dismantled, or altered only under the supervision and direction of a competent and qualified person: a) The employer erected two 12 ft. tall scaffolds for installing a decorative metal curtain along the 25 ft tall wall (18th floor lobby). The scaffolds were not tall enough, did not have safety guardrails and fully planked platforms; employer used wood screwed together without tie wire to secure the connections. Employees were exposed to scaffold collapse hazard and fall hazard. Location: 125 Park Ave, New York, N.Y. On or about 2/10/2014 NOTE: BECAUSE THE EMPLOYER CORRECTED THIS CONDITION DURING THE INSPECTION THE EMPLOYER IS NOT REQUIRED TO SUBMIT ABATEMENT CERTIFICATION NOR DOCUMENTATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2014-03-21
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-04-17
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1m) above a lower level was not protected from falling to that lower level. Paragraphs (g)(1)(i) though (vii) establish the types of fall protection to be provided to employees on each type of scaffold. Paragraph (g)(2) addresses fall protection for scaffold erectors and dismantlers: a) Employees were exposed to 12 ft fall hazard when working on the two 12 ft tall scaffolds in the 18th floor lobby without guardrails or personal fall protection systems (harness connected to a lifeline). Location: 125 Park Ave, New York, N.Y. On or about 2/10/2014 NOTE: BECAUSE THE EMPLOYER CORRECTED THIS ITEM DURING THE INSPECTION, THE EMPLOYER IS NOT REQUIRED TO SUBMIT ABATEMENT CERTIFICATION NOR DOCUMENTATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2014-03-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-17
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. Guardrail systems were not installed before the scaffold is released for use by employees other than erecting/dismantling crews: a) Two 12 ft tall scaffolds were not provided with guardrails along the work platforms; 18th floor lobby. Employees were exposed to 12 ft fall hazard. Location: 125 Park Ave, New York, N.Y. On or about 2/10/2014 NOTE: BECAUSE THE EMPLOYER CORRECTED THIS CONDITION DURING THE INSPECTION THE EMPLOYER IS NOT REQUIRED TO SUBMIT ABATEMENT CERTIFICATION NOR DOCUMENTATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2014-03-21
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-04-17
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) The employer had not provided fall protection training to employees who were using 12 ft tall scaffolds without fall protection in the 18th floor lobby. Location: 125 Park Ave, New York, N.Y. On or about 2/10/2014 NOTE: BECAUSE THE EMPLOYER CORRECTED THIS ITEM DURING THE INSPECTION THE EMPLOYER IS NOT REQUIRED TO SUBMIT ABATEMENT CERTIFICATION NOR DOCUMENTATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.