Search icon

JOSEPH BARONE CONSTRUCTION CORP.

Company Details

Name: JOSEPH BARONE CONSTRUCTION CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 18 Mar 2009 (16 years ago)
Entity Number: 3787551
ZIP code: 13363
County: Onondaga
Place of Formation: New York
Address: 6088 Cemetery Rd, 333 E ONONDAGA ST, Lee Center, NY, United States, 13363
Principal Address: 6088 Cemetery Rd, Lee Center, NY, United States, 13363

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
JOSEPH BARONE DOS Process Agent 6088 Cemetery Rd, 333 E ONONDAGA ST, Lee Center, NY, United States, 13363

Chief Executive Officer

Name Role Address
JOSEPH BARONE Chief Executive Officer 6088 CEMETERY RD, LEE CENTER, NY, United States, 13363

Filings

Filing Number Date Filed Type Effective Date
211209002597 2021-12-09 BIENNIAL STATEMENT 2021-12-09
090318000364 2009-03-18 CERTIFICATE OF INCORPORATION 2009-03-18

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
334488731 0215800 2012-04-25 927 MILL STREET NORTH, WATERTOWN, NY, 13601
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-04-25
Emphasis L: LOCALTARG
Case Closed 2015-05-11

Related Activity

Type Inspection
Activity Nr 448773
Safety Yes
Type Inspection
Activity Nr 448353
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 D01 III
Issuance Date 2012-08-17
Abatement Due Date 2012-09-16
Current Penalty 1200.0
Initial Penalty 2310.0
Contest Date 2012-09-10
Final Order 2013-01-11
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form. a) At the jobsite, on or about 4/25/12: An employee was dry cutting brick without the employer providing an evaluation of the respiratory hazards from performing this work. Abatement certification must be submitted for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 C
Issuance Date 2012-08-17
Abatement Due Date 2012-09-16
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2012-09-10
Final Order 2013-01-11
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: a) At the jobsite, on or about 4/25/12: An employee was dry cutting brick without the employer providing a written and implemented respiratory protection program. Abatement certification must be submitted for this item.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2012-08-17
Abatement Due Date 2012-09-16
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2012-09-10
Final Order 2013-01-11
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) At the jobsite, on or about 4/25/12: An employee was dry cutting brick without a written and implemented respiratory protection program and without being provided a medical evaluation to determine the employees ability to use a respirator. Abatement certification must be submitted for this item.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100134 F02
Issuance Date 2012-08-17
Abatement Due Date 2012-09-16
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2012-09-10
Final Order 2013-01-11
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: (Construction Reference 1926.103) a) At the jobsite, on or about 4/25/12: An employee was dry cutting brick without a written and implemented respiratory protection program and without being provided a medical evaluation to determine the employees ability to use a respirator and without being fit tested to wear the tight fitting respirator. Abatement certification must be submitted for this item.

Date of last update: 10 Mar 2025