Search icon

PREMIER BUILDERS MN LLC

Company Details

Name: PREMIER BUILDERS MN LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 20 Mar 2009 (16 years ago)
Entity Number: 3788607
ZIP code: 11228
County: Richmond
Place of Formation: New York
Address: 7014 13TH AVENUE, STE 202, BROOKLYN, NY, United States, 11228

Agent

Name Role Address
UNITED STATES CORPORATION AGENTS, INC. Agent 7014 13TH AVENUE, STE 202, BROOKLYN, NY, 11228

DOS Process Agent

Name Role Address
C/O UNITED STATES CORPORATION AGENTS, INC. DOS Process Agent 7014 13TH AVENUE, STE 202, BROOKLYN, NY, United States, 11228

Filings

Filing Number Date Filed Type Effective Date
110526002202 2011-05-26 BIENNIAL STATEMENT 2011-03-01
090320000107 2009-03-20 ARTICLES OF ORGANIZATION 2009-03-20

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339489502 0214700 2013-11-15 471 MONTAUK HWY, WEST ISLIP, NY, 11795
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-11-15
Emphasis L: FALL, P: FALL
Case Closed 2014-10-16

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2014-02-26
Abatement Due Date 2014-03-04
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2014-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) Worksite, Northeast - Employees were working on a scaffold at the heights of approximately 22 feet. The scaffold base plate was not positioned on a mud sill to prevent settling; on or about 11/15/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2014-02-26
Abatement Due Date 2014-03-04
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2014-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) Worksite, Northeast - Employees were working on a scaffold at the heights of approximately 22 feet. Personnel were accessing the top platform by climbing the scaffold. There was no safe access; on or about 11/15/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2014-02-26
Abatement Due Date 2014-03-04
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2014-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected under the supervision and direction of a competent person qualified in scaffold erection, an activity, which should only be performed by experienced and trained employees selected for such work by the competent person. a) Worksite, Northeast - Employees were working on a scaffold at the heights of approximately 22 feet. The scaffold was not joined together vertically; and fall protection system(s) and baseplates were not installed. The scaffold was constructed by workers without direction from a competent person; on or about 11/15/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2014-02-26
Abatement Due Date 2014-03-04
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2014-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Worksite, Northeast - Employees were working on a scaffold at the heights of approximately 22 feet without being protected from falls. Personal falls arrest systems or guardrails were not used; on or about 11/15/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260452 C03
Issuance Date 2014-02-26
Abatement Due Date 2014-03-04
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2014-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(3): Frames and panels were not joined together vertically by coupling or stacking pins or equivalent means: a) Worksite, Northeast - Employees were working on a scaffold at heights of approximately 22 feet. A small scaffold structure was positioned on a larger structure without being secured to the lower scaffold; on or about 11/15/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2014-02-26
Abatement Due Date 2014-03-10
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2014-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Worksite, Northeast - Employees were working on a scaffold at the heights of approximately 22 feet. The workers using the scaffold system were not trained to recognize relative hazards; on or about 11/15/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.

Date of last update: 27 Mar 2025

Sources: New York Secretary of State