Search icon

MIKE LAIRD CONSTRUCTION, LLC

Company Details

Name: MIKE LAIRD CONSTRUCTION, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 11 May 2009 (16 years ago)
Entity Number: 3808653
ZIP code: 13140
County: Cayuga
Place of Formation: New York
Address: 8453 WEST LOOP ROAD, PORT BYRON, NY, United States, 13140

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent 8453 WEST LOOP ROAD, PORT BYRON, NY, United States, 13140

Filings

Filing Number Date Filed Type Effective Date
210803003812 2021-08-03 BIENNIAL STATEMENT 2021-08-03
190717002044 2019-07-17 BIENNIAL STATEMENT 2019-05-01
110524002915 2011-05-24 BIENNIAL STATEMENT 2011-05-01
090702000730 2009-07-02 CERTIFICATE OF PUBLICATION 2009-07-02
090511000115 2009-05-11 ARTICLES OF ORGANIZATION 2009-05-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343098505 0215800 2018-03-29 14 EAST BAIRD STREET, SENECA FALLS, NY, 13148
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2018-03-29
Emphasis L: LOCALTARG, P: LOCALTARG
Case Closed 2019-02-08

Related Activity

Type Inspection
Activity Nr 1310093
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260034 A
Issuance Date 2018-06-01
Abatement Due Date 2018-06-07
Current Penalty 250.0
Initial Penalty 3880.0
Contest Date 2018-06-13
Final Order 2018-11-21
Nr Instances 2
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.34(a): Building or structure exits were not so arranged and maintained as to provide free and unobstructed egress from all parts of the building or structure at all times when it was occupied: a) At the jobsite, in the basement, on or about 3/29/18: There was no available means of egress from the street side unit without passing between studded walls. b) At the jobsite, on the main floor, on or about 3/29/18: The means of egress from the street side of the building would require jumping down from the platform (greater than 8 feet to grade) where there are no stairs and no ladder.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260403 B01
Issuance Date 2018-06-01
Abatement Due Date 2018-06-07
Current Penalty 250.0
Initial Penalty 3880.0
Contest Date 2018-06-13
Final Order 2018-11-21
Nr Instances 2
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: a) At the jobsite, in the basement, on or about 3/29/18: Workers were exposed to electrical hazards where an outlet box was used to hard-wire a space heater and the live wires were exposed to incidental contact.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260403 B01 I
Issuance Date 2018-06-01
Abatement Due Date 2018-06-07
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2018-06-13
Final Order 2018-11-21
Nr Instances 2
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose. a) At the jobsite, in the basement, on or about 3/29/18: Workers were exposed to electrical hazards when a metal quad box was used to source electricity to a heater, where that box was not attached to a solid surface as it is designed to be. b) At the jobsite, in the basement, on or about 3/29/18: Workers were exposed to electrical hazards when a heater plug was removed and hard wired into the electrical power source.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2018-06-01
Abatement Due Date 2018-06-07
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2018-06-13
Final Order 2018-11-21
Nr Instances 1
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) At the jobsite, in the basement, on or about 3/29/18: Workers were using power tools, energized without GFCI protection.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2018-06-01
Abatement Due Date 2018-06-07
Current Penalty 250.0
Initial Penalty 3880.0
Contest Date 2018-06-13
Final Order 2018-11-21
Nr Instances 2
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) At the jobsite, at the first floor entrance, on or about 3/29/18: Workers were not protected from falling eight feet to ground.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19261052 C01 II
Issuance Date 2018-06-01
Abatement Due Date 2018-06-07
Current Penalty 250.0
Initial Penalty 3326.0
Contest Date 2018-06-13
Final Order 2018-11-21
Nr Instances 2
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) At the jobsite, at the first floor entrance, on or about 3/29/18: Workers were not provided a handrail on each side of the stairway to access the building.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19261052 C04
Issuance Date 2018-06-01
Abatement Due Date 2018-06-07
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2018-06-13
Final Order 2018-11-21
Nr Instances 2
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(4): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stairrail system and the stairway steps: a) At the jobsite, at the first floor entrance, on or about 3/29/18: Workers were not provided a midrail on the stairway to access the building.