336863782
|
0213100
|
2012-10-15
|
NEW LOUDON ROAD, LATHAM, NY, 12110
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-10-15
|
Emphasis |
N: TRENCH
|
Case Closed |
2018-08-20
|
Related Activity
Type |
Complaint |
Activity Nr |
605712 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
686638 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260651 K01 |
Issuance Date |
2012-11-20 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2012-12-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems: (a) Retaining wall excavated embankment - on or about October 15, 2012 and prior - excavation was not inspected and proper protective systems were not designed by a competent person to prevent a cave-in hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
2012-11-20 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2012-12-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). (a) Retaining wall excavated embankment - on or about October 15, 2012 and prior - proper protective systems were not in place to prevent a cave-in hazard. |
|
|
336859384
|
0213100
|
2012-10-11
|
37 LUZERNE RD., QUEENSBURY, NY, 12804
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-10-11
|
Emphasis |
L: FALL
|
Case Closed |
2018-08-20
|
Related Activity
Type |
Inspection |
Activity Nr |
680398 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260150 C01 I |
Issuance Date |
2012-11-05 |
Abatement Due Date |
2012-11-09 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2012-12-03 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof: (a) Jobsite - on or about October 11, 2012 - no fire extinguishers were on site. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2012-11-05 |
Current Penalty |
1360.0 |
Initial Penalty |
1360.0 |
Final Order |
2012-12-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: (a) Building Roof - on or about October 11, 2012 - Building Roof, on or about October 11, 2012 - no conventional fall arrest systems were available on the roof deck. Roof pitch was 8 on 12. Ground to eave elevation was approximately 13 feet. |
|
|
334287919
|
0213100
|
2012-05-11
|
1741 WESTERN AVE., ALBANY, NY, 12203
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-05-11
|
Emphasis |
L: FALL
|
Case Closed |
2018-02-27
|
Related Activity
Type |
Inspection |
Activity Nr |
429431 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260025 A |
Issuance Date |
2012-09-05 |
Abatement Due Date |
2012-09-12 |
Current Penalty |
1320.0 |
Initial Penalty |
1320.0 |
Final Order |
2012-09-28 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form or scrap lumber with protruding nails was not kept clear from work areas: a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry employees were exposed to foot puncture hazards from protuding nails on scrap lumber. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2012-09-05 |
Abatement Due Date |
2012-09-12 |
Current Penalty |
2200.0 |
Initial Penalty |
2200.0 |
Final Order |
2012-09-28 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (19') nineteen feet to ground level when performing masonry work from prefabricated frame scaffolding that was not fully planked. b) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (13') thirteen feet to ground level when performing masonry work from prefabricated frame scaffolding that was not fully planked. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260451 C01 |
Issuance Date |
2012-09-05 |
Abatement Due Date |
2012-09-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-09-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (19') nineteen feet to ground level when performing masonry work from prefabricated frame scaffolding four tiers high that was not tied into the building to prevent tipping. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 I |
Issuance Date |
2012-09-05 |
Abatement Due Date |
2012-09-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-09-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement: a) a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (19') nineteen feet to ground level when performing masonry work from a prefabricated frame scaffolding that was positioned on uneven footings. |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2012-09-05 |
Abatement Due Date |
2012-09-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-09-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (19') nineteen feet to ground level when accessing a scaffolding that was not equipped with a ladder for access. |
|
Citation ID |
01002E |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2012-09-05 |
Abatement Due Date |
2012-09-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-09-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (19') nineteen feet to ground level when performing masonry work from prefabricated frame scaffolding missing end and mid-guard railing. |
|
Citation ID |
01002F |
Citaton Type |
Serious |
Standard Cited |
19260452 C04 |
Issuance Date |
2012-09-05 |
Abatement Due Date |
2012-09-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-09-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(c)(4): End frames of tubular welded frame scaffolding were not locked together vertically by use of pins or equivalent means in areas where uplift could occur: a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (19') nineteen feet to ground level when performing masonry work from prefabricated frame scaffolding not equipped with coupler pins. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260454 A |
Issuance Date |
2012-09-05 |
Abatement Due Date |
2012-09-12 |
Current Penalty |
2200.0 |
Initial Penalty |
2200.0 |
Final Order |
2012-09-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) 1741 Western Ave. Albany, NY- On or about 5/11/12- For all employees performing masonry work from prefabricated frame scaffolding; employees were not trained to recognize hazards associated with improperly erected scaffolding. |
|
|
313760217
|
0213100
|
2010-08-04
|
124 BROAD ST, PLATTSBURGH, NY, 12901
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2010-08-04
|
Emphasis |
L: LOCALTARG, S: FALL FROM HEIGHT
|
Case Closed |
2010-10-04
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2010-08-12 |
Abatement Due Date |
2010-08-20 |
Current Penalty |
1000.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2010-08-12 |
Abatement Due Date |
2010-08-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
|