Name: | SUNRISE SOLAR SOLUTIONS, LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 17 Jun 2009 (16 years ago) |
Entity Number: | 3823136 |
ZIP code: | 10510 |
County: | Westchester |
Place of Formation: | New York |
Address: | 510 NORTH STATE ROAD, BRIARCLIFF MANOR, NY, United States, 10510 |
Type | Company Name | Company Number | State |
---|---|---|---|
Headquarter of | SUNRISE SOLAR SOLUTIONS, LLC, CONNECTICUT | 1228659 | CONNECTICUT |
Name | Role | Address |
---|---|---|
THE LLC | DOS Process Agent | 510 NORTH STATE ROAD, BRIARCLIFF MANOR, NY, United States, 10510 |
Start date | End date | Type | Value |
---|---|---|---|
2009-06-17 | 2023-07-13 | Address | 510 NORTH STATE ROAD, BRIARCLIFF MANOR, NY, 10510, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
230713001438 | 2023-07-13 | BIENNIAL STATEMENT | 2023-06-01 |
210609060376 | 2021-06-09 | BIENNIAL STATEMENT | 2021-06-01 |
190911060181 | 2019-09-11 | BIENNIAL STATEMENT | 2019-06-01 |
190117060757 | 2019-01-17 | BIENNIAL STATEMENT | 2017-06-01 |
130613006249 | 2013-06-13 | BIENNIAL STATEMENT | 2013-06-01 |
110613002779 | 2011-06-13 | BIENNIAL STATEMENT | 2011-06-01 |
091005000705 | 2009-10-05 | CERTIFICATE OF PUBLICATION | 2009-10-05 |
090617000188 | 2009-06-17 | ARTICLES OF ORGANIZATION | 2009-06-17 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
338953102 | 0216000 | 2013-03-11 | 95 14TH STREET, VERPLANCK, NY, 10596 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 808815 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2013-03-22 |
Current Penalty | 1680.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-04-09 |
Nr Instances | 3 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems: location: roof on or about: 3/11/13 a) Employees, installing solar panels on a residential roof, were not using any means of fall protection. The employees were exposed to a fall of 20 1/2 feet. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2013-03-22 |
Abatement Due Date | 2013-04-24 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-04-09 |
Nr Instances | 3 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards: location: entire site on or about: 3/11/13 a) Employees, installing solar panels on a residential roof, were not protected from falling 20 1/2 feet. The employees were not provided with any fall protection training. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2013-03-22 |
Current Penalty | 720.0 |
Initial Penalty | 1200.0 |
Final Order | 2013-04-09 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did notl extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. location: between lower and upper roof on or about: 3/11/13 a) Employees were using a Werner multi purpose ladder to access the upper roof. The ladder was set up in the A-frame position. The ladder did not reach the upper roof. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19261053 B21 |
Issuance Date | 2013-03-22 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-04-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(21): Each employee shall use at least one hand to grasp the ladder when progressing up and/or down the ladder. location: front of house on or about: 3/11/13 a) An employee was using a portable metal extension ladder to access the lower roof. The employee did not have at least one hand grasp the ladder when progressing up the ladder. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
Citation ID | 01002C |
Citaton Type | Serious |
Standard Cited | 19261053 B22 |
Issuance Date | 2013-03-22 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-04-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(22): An employee shall not carry any object or load that could cause the employee to lose balance and fall: location: front of house on or about: 3/11/13 a) An employee was carring solar panels, while using a portable metal extension ladders to access the lower roof. The employee could lose balance and fall. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
Citation ID | 01002D |
Citaton Type | Serious |
Standard Cited | 19261060 A |
Issuance Date | 2013-03-22 |
Abatement Due Date | 2013-04-24 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-04-09 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, that enabled employee to recognize hazards related to ladders and stairways, and that trained each employee in the procedures to be followed to minimize these hazards: location: entire site on or about: 3/11/13 a) Employees were using portable extension ladders while engaged installing solar panels. The employees were not provided with ladder safety training. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3334308502 | 2021-02-23 | 0202 | PPS | 510 N State Rd, Briarcliff Manor, NY, 10510-1547 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9816797110 | 2020-04-15 | 0202 | PPP | 510 N STATE RD, BRIARCLIFF MANOR, NY, 10510 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 27 Mar 2025
Sources: New York Secretary of State