Name: | ERA CONTRACTING GROUP, INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Inactive |
Date of registration: | 22 Jun 2009 (16 years ago) |
Date of dissolution: | 25 Apr 2012 |
Entity Number: | 3824864 |
ZIP code: | 11363 |
County: | Queens |
Place of Formation: | New York |
Address: | 248-12 43RD AVENUE, LITTLE NECK, NY, United States, 11363 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 248-12 43RD AVENUE, LITTLE NECK, NY, United States, 11363 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
DP-2130229 | 2012-04-25 | DISSOLUTION BY PROCLAMATION | 2012-04-25 |
090622000196 | 2009-06-22 | CERTIFICATE OF INCORPORATION | 2009-06-22 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
334274941 | 0215600 | 2012-05-04 | 14-30 158 STREET, BEECHHURST, NY, 11357 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 348986 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2012-09-26 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2012-10-25 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about May 11, 2012-Job site at 14-30 158 Street Beech Hurst, NY 11357 Employees exposed to overhead hazards from slate roof tiles. WRITTEN ABATEMENT DOCUMENTATION IS NOT REQUIRED. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2012-09-26 |
Current Penalty | 2400.0 |
Initial Penalty | 2400.0 |
Final Order | 2012-10-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii: a) On or about May 11, 2012-Job site at 14-30 158 Street Beech Hurst, NY 11357 Employees were exposed to tubular welded scaffold that was not fully planked. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2012-09-26 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-10-25 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a) On or about May 11, 2012-Job site at 14-30 158 Street Beech Hurst, NY 11357 Employee exposed to fall of 20-feet when climbing tubular welded frame scaffold WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2012-09-26 |
Abatement Due Date | 2012-11-08 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2012-10-25 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) On or about May 11, 2012-Job site at 14-30 158 Street Beech Hurst, NY 11357 Employees were not able to identify or correct scaffold hazards. WRITTEN ABATEMENT DOCUMENTATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Date of last update: 27 Mar 2025
Sources: New York Secretary of State